Daytona Beach, City Of Water System

MyTapWater.org's tap water quality report is the compilation of data collected from federal, state, and local government agencies, most prominently the EPA. We strive to populate the report with the latest data concerning water contaminants, lead and copper levels, and water quality violations. We only collect drinking water data from public water systems.

PWS Service Information
PWS ID: FL3640275
Type: Community water system
EPA Region: 04
Primary Service Area: Municipality
Primary Source: Ground water
Population Served: 90,620
Contact Information
DAYTONA BEACH, CITY OF
MS. JOANN MACRINA
DAYTONA BEACH UTILITY DIRECTOR
125 BASIN STREET, SUITE 130
DAYTONA BEACH, FL 32114

This public water system services 1 municipality in 1 county.

Summary Results


A summary view of tests in which a water contaminant found to exceed the Maximum Contaminant Level (MCL) set by the EPA.

Maximum Contaminant Levels Exceeded (by year):

2013   (1) 2014   (0) 2015   (0) 2016   (0) 2017   (0) 2018   (0)
chlorate

Contaminant Detailed Results


This a view of violations of maximum contaminant levels. Use the expanded view see result data for a drinking water contaminant, the minimum level that can be recognized in a test (MRL), and upper limit that is considered healthy (HRL).

chlorate

Year Test Date MRLMinimum Reporting Level HRLHealth Risk Limit Test Result
2013 2013-11-25 20 210 586
2013 2013-11-25 20 210 418
2013 2013-05-15 20 210 762
2013 2013-05-15 20 210 583

Other Water Contaminants Tested


The following contaminants were tested and found to be within national EPA guidelines.

Contaminant MRLMinimum Reporting Level HRLHealth Risk Limit Avg Result
chromium 0.2 100 0.49 [+] Expand Test Data
Year Test Date MRL HRL Test Result
2014 2014-01-09 0.2 100 0.46
2014 2014-01-09 0.2 100 0.59
2013 2013-05-15 0.2 100 0.45
2013 2013-05-15 0.2 100 0.46
cobalt 1 70 < 1 [+] Expand Test Data
Year Test Date MRL HRL Test Result
2013 2013-11-25 1 70 < 1
2013 2013-11-25 1 70 < 1
2013 2013-05-15 1 70 < 1
2013 2013-05-15 1 70 < 1
molybdenum 1 40 < 1 [+] Expand Test Data
Year Test Date MRL HRL Test Result
2013 2013-11-25 1 40 < 1
2013 2013-11-25 1 40 < 1
2013 2013-05-15 1 40 < 1
2013 2013-05-15 1 40 < 1
strontium 0.3 1500 109.2 [+] Expand Test Data
Year Test Date MRL HRL Test Result
2013 2013-11-25 0.3 1500 117
2013 2013-11-25 0.3 1500 119
2013 2013-05-15 0.3 1500 99.8
2013 2013-05-15 0.3 1500 101
vanadium 0.2 21 0.85 [+] Expand Test Data
Year Test Date MRL HRL Test Result
2013 2013-11-25 0.2 21 0.87
2013 2013-11-25 0.2 21 0.84
2013 2013-05-15 0.2 21 0.84
2013 2013-05-15 0.2 21 0.85
chromium-6 0.03 0 0.4225 [+] Expand Test Data
Year Test Date MRL HRL Test Result
2013 2013-11-25 0.03 0 0.44
2013 2013-11-25 0.03 0 0.69
2013 2013-05-22 0.03 0 0.3
2013 2013-05-15 0.03 0 0.26
1,1-dichloroethane 0.03 6.14 < 0.03 [+] Expand Test Data
Year Test Date MRL HRL Test Result
2013 2013-11-25 0.03 6.14 < 0.03
2013 2013-05-15 0.03 6.14 < 0.03
1,2,3-trichloropropane 0.03 0.0004 < 0.03 [+] Expand Test Data
Year Test Date MRL HRL Test Result
2013 2013-11-25 0.03 0.0004 < 0.03
2013 2013-05-15 0.03 0.0004 < 0.03
1,3-butadiene 0.1 0.0103 < 0.1 [+] Expand Test Data
Year Test Date MRL HRL Test Result
2013 2013-11-25 0.1 0.0103 < 0.1
2013 2013-05-15 0.1 0.0103 < 0.1
1,4-dioxane 0.07 0.35 < 0.07 [+] Expand Test Data
Year Test Date MRL HRL Test Result
2013 2013-11-25 0.07 0.35 < 0.07
2013 2013-05-15 0.07 0.35 < 0.07
17-alpha-ethynylestradiol 0.0009 0.035 < 0.0009 [+] Expand Test Data
Year Test Date MRL HRL Test Result
2013 2013-11-25 0.0009 0.035 < 0.0009
2013 2013-05-15 0.0009 0.035 < 0.0009
17-beta-estradiol 0.0004 0.0009 < 0.0004 [+] Expand Test Data
Year Test Date MRL HRL Test Result
2013 2013-11-25 0.0004 0.0009 < 0.0004
2013 2013-05-15 0.0004 0.0009 < 0.0004
4-androstene-3,17-dione 0.0003 0 < 0.0003 [+] Expand Test Data
Year Test Date MRL HRL Test Result
2013 2013-11-25 0.0003 0 < 0.0003
2013 2013-05-15 0.0003 0 < 0.0003
bromomethane 0.2 140 < 0.2 [+] Expand Test Data
Year Test Date MRL HRL Test Result
2013 2013-11-25 0.2 140 < 0.2
2013 2013-05-15 0.2 140 < 0.2
chloromethane 0.2 2.69 < 0.2 [+] Expand Test Data
Year Test Date MRL HRL Test Result
2013 2013-11-25 0.2 2.69 < 0.2
2013 2013-05-15 0.2 2.69 < 0.2
equilin 0.004 0.35 < 0.004 [+] Expand Test Data
Year Test Date MRL HRL Test Result
2013 2013-11-25 0.004 0.35 < 0.004
2013 2013-05-15 0.004 0.35 < 0.004
estriol 0.0008 0.35 < 0.0008 [+] Expand Test Data
Year Test Date MRL HRL Test Result
2013 2013-11-25 0.0008 0.35 < 0.0008
2013 2013-05-15 0.0008 0.35 < 0.0008
estrone 0.002 0.35 < 0.002 [+] Expand Test Data
Year Test Date MRL HRL Test Result
2013 2013-11-25 0.002 0.35 < 0.002
2013 2013-05-15 0.002 0.35 < 0.002
Halon 1011 0.06 90 < 0.06 [+] Expand Test Data
Year Test Date MRL HRL Test Result
2013 2013-11-25 0.06 90 < 0.06
2013 2013-05-15 0.06 90 < 0.06
HCFC-22 0.08 0 < 0.08 [+] Expand Test Data
Year Test Date MRL HRL Test Result
2013 2013-11-25 0.08 0 < 0.08
2013 2013-05-15 0.08 0 < 0.08
PFBS 0.09 0 < 0.09 [+] Expand Test Data
Year Test Date MRL HRL Test Result
2013 2013-11-25 0.09 0 < 0.09
2013 2013-05-15 0.09 0 < 0.09
PFHpA 0.01 0 < 0.01 [+] Expand Test Data
Year Test Date MRL HRL Test Result
2013 2013-11-25 0.01 0 < 0.01
2013 2013-05-15 0.01 0 < 0.01
PFHxS 0.03 0 < 0.03 [+] Expand Test Data
Year Test Date MRL HRL Test Result
2013 2013-11-25 0.03 0 < 0.03
2013 2013-05-15 0.03 0 < 0.03
PFNA 0.02 0 < 0.02 [+] Expand Test Data
Year Test Date MRL HRL Test Result
2013 2013-11-25 0.02 0 < 0.02
2013 2013-05-15 0.02 0 < 0.02
PFOA 0.02 0.07 < 0.02 [+] Expand Test Data
Year Test Date MRL HRL Test Result
2013 2013-11-25 0.02 0.07 < 0.02
2013 2013-05-15 0.02 0.07 < 0.02
PFOS 0.04 0.07 < 0.04 [+] Expand Test Data
Year Test Date MRL HRL Test Result
2013 2013-11-25 0.04 0.07 < 0.04
2013 2013-05-15 0.04 0.07 < 0.04
testosterone 0.0001 0 < 0.0001 [+] Expand Test Data
Year Test Date MRL HRL Test Result
2013 2013-11-25 0.0001 0 < 0.0001
2013 2013-05-15 0.0001 0 < 0.0001

Lead and Copper Data


Lead and copper are recorded separately from other contaminants because of the Lead and Copper Rule. As with all other results, these are the findings at the water supply level. Lead and copper can be — and often are — deposited in drinking water in between the water facility and your tap.

Sample ID Contaminant Sampling Start Date Sampling End Date Result
FL155092 lead 2017-01-01 2017-12-01 0.0021mg/L
FL133490 lead 2014-01-01 2014-12-01 0.0029mg/L
FL113230 lead 2011-01-01 2011-12-01 0.003mg/L
FL88264 lead 2008-01-01 2008-12-01 0.004mg/L

Violations


Known violations of the Safe Drinking Water Act as recorded by the EPA.

Compliance Dates Rule Violation Type Contaminant Name Status
2014-01-01 - 2014-01-31 Total Coliform Rule Maximum Contaminant Level Violation, Monthly (TCR) Coliform (TCR) Returned to Compliance
2007-07-01 - 2007-09-30 Stage 1 Disinfectants and Disinfection Byproducts Rule Monitoring and Reporting (DBP) Total Haloacetic Acids (HAA5) Returned to Compliance
2007-07-01 - 2007-09-30 Stage 1 Disinfectants and Disinfection Byproducts Rule Monitoring and Reporting (DBP) TTHM Returned to Compliance
2005-12-01 - 2005-12-31 Total Coliform Rule Maximum Contaminant Level Violation, Monthly (TCR) Coliform (TCR) Known
2001-11-01 - 2001-11-30 Total Coliform Rule Maximum Contaminant Level Violation, Monthly (TCR) Coliform (TCR) Known
2001-07-01 - N/A Consumer Confidence Rule Consumer Confidence Report Inadequate Reporting Consumer Confidence Rule Open
- N/A Total Coliform Rule Maximum Contaminant Level Violation, Monthly (TCR) Coliform (TCR) Known
- N/A Inorganic Chemicals Monitoring, Regular Selenium Known
- N/A Nitrates Monitoring, Regular Nitrate Known
- N/A Inorganic Chemicals Monitoring, Regular Mercury Known
- N/A Inorganic Chemicals Monitoring, Regular Fluoride Known
- N/A Inorganic Chemicals Monitoring, Regular Chromium Known
- N/A Inorganic Chemicals Monitoring, Regular Cadmium Known
- N/A Inorganic Chemicals Monitoring, Regular Barium Known
- N/A Arsenic Monitoring, Regular Arsenic Known
- N/A Total Coliform Rule Monitoring, Repeat Major (TCR) Coliform (TCR) Known
- N/A Total Coliform Rule Monitoring, Repeat Major (TCR) Coliform (TCR) Known
- N/A Total Coliform Rule Monitoring, Repeat Major (TCR) Coliform (TCR) Known
- N/A Total Coliform Rule Monitoring, Repeat Major (TCR) Coliform (TCR) Known
- N/A Total Coliform Rule Monitoring, Repeat Major (TCR) Coliform (TCR) Known
- N/A Total Coliform Rule Maximum Contaminant Level Violation, Monthly (TCR) Coliform (TCR) Known

Local Water Testing


Find a lab in your area so you can get your tap or well water tested. This list contains both governmental and private labs, all of which are EPA-certified for drinking water testing.

Lab Location Zip Code
Pace Analytical Services, LLC Ormond Beach FL Ormond Beach, FL 32174
Seminole Electric Cooperative Inc. Palatka, FL 32177
Florida DOH Bureau of Labs – Environmental Microbiology Jacksonville, FL 32202

Water Bill Information


Convenient information about your water service.

Unable to identify any billing information about Daytona Beach, City Of (FL3640275).

What My Water Data Means


Water data isn't always easy to interpret, but by following the links on this page you should be able to have most of your questions answered. By clicking the name of a water contaminant or secondary substance you can learn about that specific substance. Ultimately this page should give you some insight towards learning if your water is safe, what water filter you should buy (if any), and how well your local water compares against other sources.

Sources


The origin of MyTapWater.org's water data is explained on our Data Sources page.

Why Is My Water Data Not More Recent?


The recency of the data for your ZIP code depends on the last your water source was tested, by a federal, state, or local agency. More information about the timing can be determined by learning about the dataset in question and seeing how often the EPA (other another governing body) mandated testing.