Neenah Waterworks Water System

MyTapWater.org's tap water quality report is the compilation of data collected from federal, state, and local government agencies, most prominently the EPA. We strive to populate the report with the latest data concerning water contaminants, lead and copper levels, and water quality violations. We only collect drinking water data from public water systems.

PWS Service Information
PWS ID: WI4710348
Type: Community water system
EPA Region: 05
Primary Service Area: Residential Area
Primary Source: Surface water
Population Served: 25,892
Contact Information
CITY OF NEENAH DIRECTOR - KENT TAYLOR
211 WALNUT ST
NEENAH, WI 54956

This public water system services 1 municipality in 1 county.

Summary Results


A summary view of tests in which a water contaminant found to exceed the Maximum Contaminant Level (MCL) set by the EPA.

Maximum Contaminant Levels Exceeded (by year):

2013   (0) 2014   (0) 2015   (0) 2016   (0) 2017   (0) 2018   (2)
anatoxin-a
cylindrospermopsin

Contaminant Detailed Results


This a view of violations of maximum contaminant levels. Use the expanded view see result data for a drinking water contaminant, the minimum level that can be recognized in a test (MRL), and upper limit that is considered healthy (HRL).

anatoxin-a

Year Test Date MRLMinimum Reporting Level HRLHealth Risk Limit Test Result
2018 2018-08-15 0.03 0.00 < 0.03
2018 2018-08-01 0.03 0.00 < 0.03
2018 2018-07-16 0.03 0.00 < 0.03
2018 2018-07-02 0.03 0.00 < 0.03
2018 2018-06-20 0.03 0.00 < 0.03
2018 2018-06-04 0.03 0.00 < 0.03
2018 2018-05-15 0.03 0.00 < 0.03
2018 2018-05-01 0.03 0.00 < 0.03

cylindrospermopsin

Year Test Date MRLMinimum Reporting Level HRLHealth Risk Limit Test Result
2018 2018-08-15 0.09 0.00 < 0.09
2018 2018-08-01 0.09 0.00 < 0.09
2018 2018-07-16 0.09 0.00 < 0.09
2018 2018-07-02 0.09 0.00 < 0.09
2018 2018-06-20 0.09 0.00 < 0.09
2018 2018-06-04 0.09 0.00 < 0.09
2018 2018-05-15 0.09 0.00 < 0.09
2018 2018-05-01 0.09 0.00 < 0.09

Other Water Contaminants Tested


The following contaminants were tested and found to be within national EPA guidelines.

Contaminant MRLMinimum Reporting Level HRLHealth Risk Limit Avg Result
1,1-dichloroethane 0.03 6.14 < 0.03 [+] Expand Test Data
Year Test Date MRL HRL Test Result
2014 2014-08-11 0.03 6.14 < 0.03
2014 2014-04-22 0.03 6.14 < 0.03
2014 2014-01-14 0.03 6.14 < 0.03
2013 2013-10-15 0.03 6.14 < 0.03
1,2,3-trichloropropane 0.03 0.0004 < 0.03 [+] Expand Test Data
Year Test Date MRL HRL Test Result
2014 2014-08-11 0.03 0.0004 < 0.03
2014 2014-04-22 0.03 0.0004 < 0.03
2014 2014-01-14 0.03 0.0004 < 0.03
2013 2013-10-15 0.03 0.0004 < 0.03
1,3-butadiene 0.1 0.0103 < 0.1 [+] Expand Test Data
Year Test Date MRL HRL Test Result
2014 2014-08-11 0.1 0.0103 < 0.1
2014 2014-04-22 0.1 0.0103 < 0.1
2014 2014-01-14 0.1 0.0103 < 0.1
2013 2013-10-15 0.1 0.0103 < 0.1
1,4-dioxane 0.07 0.35 < 0.07 [+] Expand Test Data
Year Test Date MRL HRL Test Result
2014 2014-07-22 0.07 0.35 < 0.07
2014 2014-04-22 0.07 0.35 < 0.07
2014 2014-01-14 0.07 0.35 < 0.07
2013 2013-10-15 0.07 0.35 < 0.07
bromomethane 0.2 140 < 0.2 [+] Expand Test Data
Year Test Date MRL HRL Test Result
2014 2014-08-11 0.2 140 < 0.2
2014 2014-04-22 0.2 140 < 0.2
2014 2014-01-14 0.2 140 < 0.2
2013 2013-10-15 0.2 140 < 0.2
chlorate 20 210 90.5345 [+] Expand Test Data
Year Test Date MRL HRL Test Result
2014 2014-07-22 20 210 94.259
2014 2014-07-22 20 210 81.375
2014 2014-04-22 20 210 51.89
2014 2014-04-22 20 210 62.335
2014 2014-01-14 20 210 46.539
2014 2014-01-14 20 210 84.497
2013 2013-10-15 20 210 159.481
2013 2013-10-15 20 210 143.9
chloromethane 0.2 2.69 < 0.2 [+] Expand Test Data
Year Test Date MRL HRL Test Result
2014 2014-08-11 0.2 2.69 < 0.2
2014 2014-04-22 0.2 2.69 < 0.2
2014 2014-01-14 0.2 2.69 < 0.2
2013 2013-10-15 0.2 2.69 < 0.2
chromium 0.2 100 1.755 [+] Expand Test Data
Year Test Date MRL HRL Test Result
2014 2014-07-22 0.2 100 1.497
2014 2014-07-22 0.2 100 1.432
2014 2014-04-22 0.2 100 1.803
2014 2014-04-22 0.2 100 1.759
2014 2014-01-14 0.2 100 2.062
2014 2014-01-14 0.2 100 2.039
2013 2013-11-25 0.2 100 1.77
2013 2013-10-15 0.2 100 1.678
chromium-6 0.03 0 1.6261 [+] Expand Test Data
Year Test Date MRL HRL Test Result
2014 2014-07-22 0.03 0 1.513
2014 2014-07-22 0.03 0 1.459
2014 2014-04-22 0.03 0 1.669
2014 2014-04-22 0.03 0 1.65
2014 2014-01-14 0.03 0 1.895
2014 2014-01-14 0.03 0 1.886
2013 2013-10-15 0.03 0 1.548
2013 2013-10-15 0.03 0 1.389
cobalt 1 70 < 1 [+] Expand Test Data
Year Test Date MRL HRL Test Result
2014 2014-07-22 1 70 < 1
2014 2014-07-22 1 70 < 1
2014 2014-04-22 1 70 < 1
2014 2014-04-22 1 70 < 1
2014 2014-01-14 1 70 < 1
2014 2014-01-14 1 70 < 1
2013 2013-10-15 1 70 < 1
2013 2013-10-15 1 70 < 1
Halon 1011 0.06 90 < 0.06 [+] Expand Test Data
Year Test Date MRL HRL Test Result
2014 2014-08-11 0.06 90 < 0.06
2014 2014-04-22 0.06 90 < 0.06
2014 2014-01-14 0.06 90 < 0.06
2013 2013-10-15 0.06 90 < 0.06
HCFC-22 0.08 0 0.0203 [+] Expand Test Data
Year Test Date MRL HRL Test Result
2014 2014-08-11 0.08 0 < 0.08
2014 2014-04-22 0.08 0 < 0.08
2014 2014-01-14 0.08 0 0.081
2013 2013-10-15 0.08 0 < 0.08
molybdenum 1 40 < 1 [+] Expand Test Data
Year Test Date MRL HRL Test Result
2014 2014-07-22 1 40 < 1
2014 2014-07-22 1 40 < 1
2014 2014-04-22 1 40 < 1
2014 2014-04-22 1 40 < 1
2014 2014-01-14 1 40 < 1
2014 2014-01-14 1 40 < 1
2013 2013-10-15 1 40 < 1
2013 2013-10-15 1 40 < 1
PFBS 0.09 0 < 0.09 [+] Expand Test Data
Year Test Date MRL HRL Test Result
2014 2014-07-22 0.09 0 < 0.09
2014 2014-04-22 0.09 0 < 0.09
2014 2014-01-14 0.09 0 < 0.09
2013 2013-10-15 0.09 0 < 0.09
PFHpA 0.01 0 < 0.01 [+] Expand Test Data
Year Test Date MRL HRL Test Result
2014 2014-07-22 0.01 0 < 0.01
2014 2014-04-22 0.01 0 < 0.01
2014 2014-01-14 0.01 0 < 0.01
2013 2013-10-15 0.01 0 < 0.01
PFHxS 0.03 0 < 0.03 [+] Expand Test Data
Year Test Date MRL HRL Test Result
2014 2014-07-22 0.03 0 < 0.03
2014 2014-04-22 0.03 0 < 0.03
2014 2014-01-14 0.03 0 < 0.03
2013 2013-10-15 0.03 0 < 0.03
PFNA 0.02 0 < 0.02 [+] Expand Test Data
Year Test Date MRL HRL Test Result
2014 2014-07-22 0.02 0 < 0.02
2014 2014-04-22 0.02 0 < 0.02
2014 2014-01-14 0.02 0 < 0.02
2013 2013-10-15 0.02 0 < 0.02
PFOA 0.02 0.07 < 0.02 [+] Expand Test Data
Year Test Date MRL HRL Test Result
2014 2014-07-22 0.02 0.07 < 0.02
2014 2014-04-22 0.02 0.07 < 0.02
2014 2014-01-14 0.02 0.07 < 0.02
2013 2013-10-15 0.02 0.07 < 0.02
PFOS 0.04 0.07 < 0.04 [+] Expand Test Data
Year Test Date MRL HRL Test Result
2014 2014-07-22 0.04 0.07 < 0.04
2014 2014-04-22 0.04 0.07 < 0.04
2014 2014-01-14 0.04 0.07 < 0.04
2013 2013-10-15 0.04 0.07 < 0.04
strontium 0.3 1500 48.1331 [+] Expand Test Data
Year Test Date MRL HRL Test Result
2014 2014-07-22 0.3 1500 54.107
2014 2014-07-22 0.3 1500 52.576
2014 2014-04-22 0.3 1500 42.191
2014 2014-04-22 0.3 1500 49.076
2014 2014-01-14 0.3 1500 39.791
2014 2014-01-14 0.3 1500 42.653
2013 2013-10-15 0.3 1500 51.252
2013 2013-10-15 0.3 1500 53.419
vanadium 0.2 21 5.112 [+] Expand Test Data
Year Test Date MRL HRL Test Result
2014 2014-07-22 0.2 21 5.41
2014 2014-07-22 0.2 21 4.557
2014 2014-04-22 0.2 21 5.802
2014 2014-04-22 0.2 21 4.715
2014 2014-01-14 0.2 21 5.116
2014 2014-01-14 0.2 21 5.07
2013 2013-10-15 0.2 21 5.899
2013 2013-10-15 0.2 21 4.327

Lead and Copper Data


Lead and copper are recorded separately from other contaminants because of the Lead and Copper Rule. As with all other results, these are the findings at the water supply level. Lead and copper can be — and often are — deposited in drinking water in between the water facility and your tap.

Sample ID Contaminant Sampling Start Date Sampling End Date Result
65306980 lead 2018-06-01 2018-09-30 0.0061mg/L
61051162 lead 2017-06-01 2017-09-30 0.008mg/L
48210540 lead 2016-06-01 2016-09-30 0.011mg/L
45483196 lead 2015-07-01 2015-12-31 0.01mg/L
45483193 lead 2015-01-01 2015-06-30 0.0094mg/L
38699669 lead 2014-06-01 2014-09-30 0.018mg/L
33824425 lead 2012-06-01 2012-09-30 0.013mg/L
32260227 lead 2011-06-01 2011-09-30 0.0097mg/L
29342935 lead 2010-01-01 2010-06-30 0.0097mg/L
28088376 lead 2009-07-01 2009-12-31 0.012mg/L
28088373 lead 2009-01-01 2009-06-30 0.017mg/L
25634621 lead 2008-01-01 2008-12-31 0.033mg/L

Violations


Known violations of the Safe Drinking Water Act as recorded by the EPA.

Compliance Dates Rule Violation Type Contaminant Name Status
2013-07-01 - 2013-07-31 Total Coliform Rule Maximum Contaminant Level Violation, Monthly (TCR) Coliform (TCR) Returned to Compliance
2011-10-01 - 2011-12-31 Stage 1 Disinfectants and Disinfection Byproducts Rule Monitoring and Reporting (DBP) CARBON, TOTAL Returned to Compliance
2011-07-01 - 2011-09-30 Stage 1 Disinfectants and Disinfection Byproducts Rule Monitoring and Reporting (DBP) CARBON, TOTAL Returned to Compliance
2008-01-01 - 2008-12-31 Lead and Copper Rule Water Quality Parameter M/R Lead and Copper Rule Returned to Compliance
2007-06-01 - 2007-06-30 Total Coliform Rule Monitoring, Routine Minor (TCR) Coliform (TCR) Returned to Compliance
2007-04-01 - 2007-06-30 Stage 1 Disinfectants and Disinfection Byproducts Rule Monitoring and Reporting (DBP) Chloramine Returned to Compliance
2006-07-01 - 2006-12-31 Lead and Copper Rule Water Quality Parameter M/R Lead and Copper Rule Known
2007-01-01 - N/A Lead and Copper Rule OCCT/SOWT Study/Recommendation Lead and Copper Rule Open
2009-01-01 - N/A Lead and Copper Rule Public Education Lead and Copper Rule Returned to Compliance
2007-07-01 - N/A Public Notice Rule Public Notification Violation for NPDWR Violation Public Notice Open
2009-04-01 - N/A Public Notice Rule Public Notification Violation for NPDWR Violation Public Notice Open
2010-01-01 - N/A Public Notice Rule Public Notification Violation for NPDWR Violation Public Notice Open

Local Water Testing


Find a lab in your area so you can get your tap or well water tested. This list contains both governmental and private labs, all of which are EPA-certified for drinking water testing.

Unable to identify any nearby water testing labs near 54956.

Water Bill Information


Convenient information about your water service.

Unable to identify any billing information about Neenah Waterworks (WI4710348).

What My Water Data Means


Water data isn't always easy to interpret, but by following the links on this page you should be able to have most of your questions answered. By clicking the name of a water contaminant or secondary substance you can learn about that specific substance. Ultimately this page should give you some insight towards learning if your water is safe, what water filter you should buy (if any), and how well your local water compares against other sources.

Sources


The origin of MyTapWater.org's water data is explained on our Data Sources page.

Why Is My Water Data Not More Recent?


The recency of the data for your ZIP code depends on the last your water source was tested, by a federal, state, or local agency. More information about the timing can be determined by learning about the dataset in question and seeing how often the EPA (other another governing body) mandated testing.