Harrisonburg, City Of Water System

MyTapWater.org's tap water quality report is the compilation of data collected from federal, state, and local government agencies, most prominently the EPA. We strive to populate the report with the latest data concerning water contaminants, lead and copper levels, and water quality violations. We only collect drinking water data from public water systems.

PWS Service Information
PWS ID: VA2660345
Type: Community water system
EPA Region: 03
Primary Service Area: Residential Area
Primary Source: Surface water
Population Served: 48,914
Contact Information
COLLINS, A. MICHAEL
COLLINS, A. MICHAEL
2155 Beery Road
HARRISONBURG, VA 22801
[email protected]

This public water system services 1 municipality in 1 county.

Summary Results


A summary view of tests in which a water contaminant found to exceed the Maximum Contaminant Level (MCL) set by the EPA.

Maximum Contaminant Levels Exceeded (by year):

2013   (0) 2014   (1) 2015   (0) 2016   (0) 2017   (0) 2018   (0)
chlorate

Contaminant Detailed Results


This a view of violations of maximum contaminant levels. Use the expanded view see result data for a drinking water contaminant, the minimum level that can be recognized in a test (MRL), and upper limit that is considered healthy (HRL).

chlorate

Year Test Date MRLMinimum Reporting Level HRLHealth Risk Limit Test Result
2014 2014-09-08 20 210 312
2014 2014-09-08 20 210 519
2014 2014-06-16 20 210 469
2014 2014-06-16 20 210 320
2014 2014-03-18 20 210 121
2014 2014-03-18 20 210 129
2013 2013-12-04 20 210 154
2013 2013-12-04 20 210 163

Other Water Contaminants Tested


The following contaminants were tested and found to be within national EPA guidelines.

Contaminant MRLMinimum Reporting Level HRLHealth Risk Limit Avg Result
1,1-dichloroethane 0.03 6.14 < 0.03 [+] Expand Test Data
Year Test Date MRL HRL Test Result
2014 2014-09-08 0.03 6.14 < 0.03
2014 2014-06-16 0.03 6.14 < 0.03
2014 2014-03-18 0.03 6.14 < 0.03
2013 2013-12-04 0.03 6.14 < 0.03
1,2,3-trichloropropane 0.03 0.0004 < 0.03 [+] Expand Test Data
Year Test Date MRL HRL Test Result
2014 2014-09-08 0.03 0.0004 < 0.03
2014 2014-06-16 0.03 0.0004 < 0.03
2014 2014-03-18 0.03 0.0004 < 0.03
2013 2013-12-04 0.03 0.0004 < 0.03
1,3-butadiene 0.1 0.0103 < 0.1 [+] Expand Test Data
Year Test Date MRL HRL Test Result
2014 2014-09-08 0.1 0.0103 < 0.1
2014 2014-06-16 0.1 0.0103 < 0.1
2014 2014-03-18 0.1 0.0103 < 0.1
2013 2013-12-04 0.1 0.0103 < 0.1
1,4-dioxane 0.07 0.35 < 0.07 [+] Expand Test Data
Year Test Date MRL HRL Test Result
2014 2014-09-08 0.07 0.35 < 0.07
2014 2014-06-16 0.07 0.35 < 0.07
2014 2014-03-18 0.07 0.35 < 0.07
2013 2013-12-04 0.07 0.35 < 0.07
bromomethane 0.2 140 < 0.2 [+] Expand Test Data
Year Test Date MRL HRL Test Result
2014 2014-09-08 0.2 140 < 0.2
2014 2014-06-16 0.2 140 < 0.2
2014 2014-03-18 0.2 140 < 0.2
2013 2013-12-04 0.2 140 < 0.2
chloromethane 0.2 2.69 < 0.2 [+] Expand Test Data
Year Test Date MRL HRL Test Result
2014 2014-09-08 0.2 2.69 < 0.2
2014 2014-06-16 0.2 2.69 < 0.2
2014 2014-03-18 0.2 2.69 < 0.2
2013 2013-12-04 0.2 2.69 < 0.2
chromium 0.2 100 0.3013 [+] Expand Test Data
Year Test Date MRL HRL Test Result
2014 2014-09-08 0.2 100 0.41
2014 2014-09-08 0.2 100 0.4
2014 2014-06-16 0.2 100 0.26
2014 2014-06-16 0.2 100 0.29
2014 2014-03-18 0.2 100 0.28
2014 2014-03-18 0.2 100 0.25
2013 2013-12-04 0.2 100 0.25
2013 2013-12-04 0.2 100 0.27
chromium-6 0.03 0 0.1086 [+] Expand Test Data
Year Test Date MRL HRL Test Result
2014 2014-09-08 0.03 0 0.1
2014 2014-09-08 0.03 0 0.14
2014 2014-06-16 0.03 0 0.13
2014 2014-06-16 0.03 0 0.14
2014 2014-03-18 0.03 0 0.059
2014 2014-03-18 0.03 0 0.08
2013 2013-12-04 0.03 0 0.1
2013 2013-12-04 0.03 0 0.12
cobalt 1 70 < 1 [+] Expand Test Data
Year Test Date MRL HRL Test Result
2014 2014-09-08 1 70 < 1
2014 2014-09-08 1 70 < 1
2014 2014-06-16 1 70 < 1
2014 2014-06-16 1 70 < 1
2014 2014-03-18 1 70 < 1
2014 2014-03-18 1 70 < 1
2013 2013-12-04 1 70 < 1
2013 2013-12-04 1 70 < 1
Halon 1011 0.06 90 < 0.06 [+] Expand Test Data
Year Test Date MRL HRL Test Result
2014 2014-09-08 0.06 90 < 0.06
2014 2014-06-16 0.06 90 < 0.06
2014 2014-03-18 0.06 90 < 0.06
2013 2013-12-04 0.06 90 < 0.06
HCFC-22 0.08 0 < 0.08 [+] Expand Test Data
Year Test Date MRL HRL Test Result
2014 2014-09-08 0.08 0 < 0.08
2014 2014-06-16 0.08 0 < 0.08
2014 2014-03-18 0.08 0 < 0.08
2013 2013-12-04 0.08 0 < 0.08
molybdenum 1 40 < 1 [+] Expand Test Data
Year Test Date MRL HRL Test Result
2014 2014-09-08 1 40 < 1
2014 2014-09-08 1 40 < 1
2014 2014-06-16 1 40 < 1
2014 2014-06-16 1 40 < 1
2014 2014-03-18 1 40 < 1
2014 2014-03-18 1 40 < 1
2013 2013-12-04 1 40 < 1
2013 2013-12-04 1 40 < 1
PFBS 0.09 0 < 0.09 [+] Expand Test Data
Year Test Date MRL HRL Test Result
2014 2014-09-08 0.09 0 < 0.09
2014 2014-06-16 0.09 0 < 0.09
2014 2014-03-18 0.09 0 < 0.09
2013 2013-12-04 0.09 0 < 0.09
PFHpA 0.01 0 < 0.01 [+] Expand Test Data
Year Test Date MRL HRL Test Result
2014 2014-09-08 0.01 0 < 0.01
2014 2014-06-16 0.01 0 < 0.01
2014 2014-03-18 0.01 0 < 0.01
2013 2013-12-04 0.01 0 < 0.01
PFHxS 0.03 0 < 0.03 [+] Expand Test Data
Year Test Date MRL HRL Test Result
2014 2014-09-08 0.03 0 < 0.03
2014 2014-06-16 0.03 0 < 0.03
2014 2014-03-18 0.03 0 < 0.03
2013 2013-12-04 0.03 0 < 0.03
PFNA 0.02 0 < 0.02 [+] Expand Test Data
Year Test Date MRL HRL Test Result
2014 2014-09-08 0.02 0 < 0.02
2014 2014-06-16 0.02 0 < 0.02
2014 2014-03-18 0.02 0 < 0.02
2013 2013-12-04 0.02 0 < 0.02
PFOA 0.02 0.07 < 0.02 [+] Expand Test Data
Year Test Date MRL HRL Test Result
2014 2014-09-08 0.02 0.07 < 0.02
2014 2014-06-16 0.02 0.07 < 0.02
2014 2014-03-18 0.02 0.07 < 0.02
2013 2013-12-04 0.02 0.07 < 0.02
PFOS 0.04 0.07 < 0.04 [+] Expand Test Data
Year Test Date MRL HRL Test Result
2014 2014-09-08 0.04 0.07 < 0.04
2014 2014-06-16 0.04 0.07 < 0.04
2014 2014-03-18 0.04 0.07 < 0.04
2013 2013-12-04 0.04 0.07 < 0.04
strontium 0.3 1500 75.3375 [+] Expand Test Data
Year Test Date MRL HRL Test Result
2014 2014-09-08 0.3 1500 58.4
2014 2014-09-08 0.3 1500 66.4
2014 2014-06-16 0.3 1500 43.4
2014 2014-06-16 0.3 1500 82.8
2014 2014-03-18 0.3 1500 250
2014 2014-03-18 0.3 1500 25.4
2013 2013-12-04 0.3 1500 35.3
2013 2013-12-04 0.3 1500 41
vanadium 0.2 21 0.3338 [+] Expand Test Data
Year Test Date MRL HRL Test Result
2014 2014-09-08 0.2 21 0.6
2014 2014-09-08 0.2 21 0.62
2014 2014-06-16 0.2 21 0.31
2014 2014-06-16 0.2 21 0.3
2014 2014-03-18 0.2 21 < 0.2
2014 2014-03-18 0.2 21 0.22
2013 2013-12-04 0.2 21 0.3
2013 2013-12-04 0.2 21 0.32

Lead and Copper Data


Lead and copper are recorded separately from other contaminants because of the Lead and Copper Rule. As with all other results, these are the findings at the water supply level. Lead and copper can be — and often are — deposited in drinking water in between the water facility and your tap.

Sample ID Contaminant Sampling Start Date Sampling End Date Result
VA28450 lead 2017-01-01 2019-12-31 0.0036mg/L
VA24698 lead 2014-01-01 2016-12-31 0.001mg/L
VA20012 lead 2011-01-01 2013-12-31 0.001mg/L
VA16178 lead 2008-01-01 2010-12-31 0.001mg/L

Violations


Known violations of the Safe Drinking Water Act as recorded by the EPA.

Compliance Dates Rule Violation Type Contaminant Name Status
2003-10-01 - 2003-10-31 Long Term 1 Enhanced Surface Water Treatment Rule Monitoring, Turbidity (Enhanced SWTR) Interim Enhanced Surfsce Water Treatment Rule Returned to Compliance
2003-03-01 - 2003-03-31 Total Coliform Rule Monitoring, Routine Minor (TCR) Coliform (TCR) Returned to Compliance
2002-02-01 - 2002-02-28 Total Coliform Rule Monitoring, Repeat Minor (TCR) Coliform (TCR) Returned to Compliance
- N/A Inorganic Chemicals Monitoring, Regular Fluoride Known
- N/A Lead and Copper Rule Initial Tap Sampling for Pb and Cu Lead and Copper Rule Returned to Compliance
- N/A Inorganic Chemicals Monitoring, Regular Fluoride Known
- N/A Inorganic Chemicals Monitoring, Regular Mercury Known
- N/A Inorganic Chemicals Monitoring, Regular Mercury Known
- N/A Synthetic Organic Chemicals Monitoring, Regular Methoxychlor Known
- N/A Synthetic Organic Chemicals Monitoring, Regular Methoxychlor Known
- N/A Nitrates Monitoring, Regular Nitrate Known
- N/A Nitrates Monitoring, Regular Nitrate Known
- N/A Inorganic Chemicals Monitoring, Regular Selenium Known
- N/A Inorganic Chemicals Monitoring, Regular Selenium Known
- N/A Synthetic Organic Chemicals Monitoring, Regular Toxaphene Known
- N/A Synthetic Organic Chemicals Monitoring, Regular Toxaphene Known
2008-01-01 - N/A Long Term 2 Enhanced Surface Water Treatment Rule Monitoring, Source Water (LT2) Long Term 2 Enhanced Surface Water Treatment Rule Returned to Compliance
- N/A Synthetic Organic Chemicals Monitoring, Regular Endrin Known
- N/A Synthetic Organic Chemicals Monitoring, Regular Endrin Known
- N/A Inorganic Chemicals Monitoring, Regular Chromium Known
- N/A Inorganic Chemicals Monitoring, Regular Chromium Known
- N/A Inorganic Chemicals Monitoring, Regular Cadmium Known
- N/A Inorganic Chemicals Monitoring, Regular Cadmium Known
- N/A Synthetic Organic Chemicals Monitoring, Regular BHC-GAMMA Known
- N/A Synthetic Organic Chemicals Monitoring, Regular BHC-GAMMA Known
- N/A Inorganic Chemicals Monitoring, Regular Barium Known
- N/A Inorganic Chemicals Monitoring, Regular Barium Known
- N/A Arsenic Monitoring, Regular Arsenic Known
- N/A Arsenic Monitoring, Regular Arsenic Known
- N/A Synthetic Organic Chemicals Monitoring, Regular 2,4,5-TP Known
- N/A Synthetic Organic Chemicals Monitoring, Regular 2,4,5-TP Known
- N/A Synthetic Organic Chemicals Monitoring, Regular 2,4-D Known
- N/A Synthetic Organic Chemicals Monitoring, Regular 2,4-D Known

Local Water Testing


Find a lab in your area so you can get your tap or well water tested. This list contains both governmental and private labs, all of which are EPA-certified for drinking water testing.

Unable to identify any nearby water testing labs near 22801.

Water Bill Information


Convenient information about your water service.

Unable to identify any billing information about Harrisonburg, City Of (VA2660345).

What My Water Data Means


Water data isn't always easy to interpret, but by following the links on this page you should be able to have most of your questions answered. By clicking the name of a water contaminant or secondary substance you can learn about that specific substance. Ultimately this page should give you some insight towards learning if your water is safe, what water filter you should buy (if any), and how well your local water compares against other sources.

Sources


The origin of MyTapWater.org's water data is explained on our Data Sources page.

Why Is My Water Data Not More Recent?


The recency of the data for your ZIP code depends on the last your water source was tested, by a federal, state, or local agency. More information about the timing can be determined by learning about the dataset in question and seeing how often the EPA (other another governing body) mandated testing.