South Jordan City Water System

MyTapWater.org's tap water quality report is the compilation of data collected from federal, state, and local government agencies, most prominently the EPA. We strive to populate the report with the latest data concerning water contaminants, lead and copper levels, and water quality violations. We only collect drinking water data from public water systems.

PWS Service Information
PWS ID: UTAH18023
Type: Community water system
EPA Region: 08
Primary Service Area: Residential Area
Primary Source: Surface water purchased
Population Served: 57,067
Contact Information
GARRISON, RAYMOND HAROLD
GARRISON, RAYMOND HAROLD
4737 W COBBLEFIELD DR
HERRIMAN, UT 84096
[email protected]

This public water system services 1 municipality in 1 county.

Summary Results


A summary view of tests in which a water contaminant found to exceed the Maximum Contaminant Level (MCL) set by the EPA.

Maximum Contaminant Levels Exceeded (by year):

2013   (0) 2014   (0) 2015   (0) 2016   (0) 2017   (0) 2018   (2)
anatoxin-a
cylindrospermopsin

Contaminant Detailed Results


This a view of violations of maximum contaminant levels. Use the expanded view see result data for a drinking water contaminant, the minimum level that can be recognized in a test (MRL), and upper limit that is considered healthy (HRL).

anatoxin-a

Year Test Date MRLMinimum Reporting Level HRLHealth Risk Limit Test Result
2018 2018-07-05 0.03 0.00 < 0.03

cylindrospermopsin

Year Test Date MRLMinimum Reporting Level HRLHealth Risk Limit Test Result
2018 2018-07-05 0.09 0.00 < 0.09

Other Water Contaminants Tested


The following contaminants were tested and found to be within national EPA guidelines.

Contaminant MRLMinimum Reporting Level HRLHealth Risk Limit Avg Result
1,4-dioxane 0.07 0.35 < 0.07 [+] Expand Test Data
Year Test Date MRL HRL Test Result
2015 2015-12-08 0.07 0.35 < 0.07
2013 2013-09-16 0.07 0.35 < 0.07
2013 2013-06-10 0.07 0.35 < 0.07
2013 2013-03-11 0.07 0.35 < 0.07
chromium-6 0.03 0 0.2503 [+] Expand Test Data
Year Test Date MRL HRL Test Result
2015 2015-12-10 0.03 0 0.0964
2015 2015-12-08 0.03 0 0.165
2013 2013-09-16 0.03 0 0.406
2013 2013-09-16 0.03 0 0.812
2013 2013-06-10 0.03 0 0.0951
2013 2013-06-10 0.03 0 0.0858
2013 2013-03-11 0.03 0 0.185
2013 2013-03-11 0.03 0 0.157
PFBS 0.09 0 < 0.09 [+] Expand Test Data
Year Test Date MRL HRL Test Result
2015 2015-12-08 0.09 0 < 0.09
2015 2015-09-30 0.09 0 < 0.09
2015 2015-07-06 0.09 0 < 0.09
2013 2013-03-11 0.09 0 < 0.09
PFHpA 0.01 0 < 0.01 [+] Expand Test Data
Year Test Date MRL HRL Test Result
2015 2015-12-08 0.01 0 < 0.01
2015 2015-09-30 0.01 0 < 0.01
2015 2015-07-06 0.01 0 < 0.01
2013 2013-03-11 0.01 0 < 0.01
PFHxS 0.03 0 < 0.03 [+] Expand Test Data
Year Test Date MRL HRL Test Result
2015 2015-12-08 0.03 0 < 0.03
2015 2015-09-30 0.03 0 < 0.03
2015 2015-07-06 0.03 0 < 0.03
2013 2013-03-11 0.03 0 < 0.03
PFNA 0.02 0 < 0.02 [+] Expand Test Data
Year Test Date MRL HRL Test Result
2015 2015-12-08 0.02 0 < 0.02
2015 2015-09-30 0.02 0 < 0.02
2015 2015-07-06 0.02 0 < 0.02
2013 2013-03-11 0.02 0 < 0.02
PFOA 0.02 0.07 < 0.02 [+] Expand Test Data
Year Test Date MRL HRL Test Result
2015 2015-12-08 0.02 0.07 < 0.02
2015 2015-09-30 0.02 0.07 < 0.02
2015 2015-07-06 0.02 0.07 < 0.02
2013 2013-03-11 0.02 0.07 < 0.02
PFOS 0.04 0.07 < 0.04 [+] Expand Test Data
Year Test Date MRL HRL Test Result
2015 2015-12-08 0.04 0.07 < 0.04
2015 2015-09-30 0.04 0.07 < 0.04
2015 2015-07-06 0.04 0.07 < 0.04
2013 2013-03-11 0.04 0.07 < 0.04
cobalt 1 70 < 1 [+] Expand Test Data
Year Test Date MRL HRL Test Result
2013 2013-12-30 1 70 < 1
2013 2013-12-30 1 70 < 1
2013 2013-09-16 1 70 < 1
2013 2013-09-16 1 70 < 1
2013 2013-06-10 1 70 < 1
2013 2013-06-10 1 70 < 1
2013 2013-04-02 1 70 < 1
2013 2013-04-02 1 70 < 1
molybdenum 1 40 1.5269 [+] Expand Test Data
Year Test Date MRL HRL Test Result
2013 2013-12-30 1 40 1.347
2013 2013-12-30 1 40 1.836
2013 2013-09-16 1 40 1.526
2013 2013-09-16 1 40 2.971
2013 2013-06-10 1 40 1.153
2013 2013-06-10 1 40 1.358
2013 2013-04-02 1 40 1
2013 2013-04-02 1 40 1.024
strontium 0.3 1500 352.3875 [+] Expand Test Data
Year Test Date MRL HRL Test Result
2013 2013-12-30 0.3 1500 299
2013 2013-12-30 0.3 1500 420.2
2013 2013-09-16 0.3 1500 352
2013 2013-09-16 0.3 1500 329
2013 2013-06-10 0.3 1500 348.2
2013 2013-06-10 0.3 1500 332.7
2013 2013-04-02 0.3 1500 366
2013 2013-04-02 0.3 1500 372
vanadium 0.2 21 0.6946 [+] Expand Test Data
Year Test Date MRL HRL Test Result
2013 2013-12-30 0.2 21 0.616
2013 2013-12-30 0.2 21 0.739
2013 2013-09-16 0.2 21 0.864
2013 2013-09-16 0.2 21 0.64
2013 2013-06-10 0.2 21 0.712
2013 2013-06-10 0.2 21 0.641
2013 2013-04-02 0.2 21 0.695
2013 2013-04-02 0.2 21 0.65
1,1-dichloroethane 0.03 6.14 < 0.03 [+] Expand Test Data
Year Test Date MRL HRL Test Result
2015 2015-12-08 0.03 6.14 < 0.03
2015 2015-09-30 0.03 6.14 < 0.03
2015 2015-03-30 0.03 6.14 < 0.03
2013 2013-06-10 0.03 6.14 < 0.03
1,2,3-trichloropropane 0.03 0.0004 < 0.03 [+] Expand Test Data
Year Test Date MRL HRL Test Result
2015 2015-12-08 0.03 0.0004 < 0.03
2015 2015-09-30 0.03 0.0004 < 0.03
2015 2015-03-30 0.03 0.0004 < 0.03
2013 2013-06-10 0.03 0.0004 < 0.03
1,3-butadiene 0.1 0.0103 < 0.1 [+] Expand Test Data
Year Test Date MRL HRL Test Result
2015 2015-12-08 0.1 0.0103 < 0.1
2015 2015-09-30 0.1 0.0103 < 0.1
2015 2015-03-30 0.1 0.0103 < 0.1
2013 2013-06-10 0.1 0.0103 < 0.1
bromomethane 0.2 140 < 0.2 [+] Expand Test Data
Year Test Date MRL HRL Test Result
2015 2015-12-08 0.2 140 < 0.2
2015 2015-09-30 0.2 140 < 0.2
2015 2015-03-30 0.2 140 < 0.2
2013 2013-06-10 0.2 140 < 0.2
chlorate 20 210 73.125 [+] Expand Test Data
Year Test Date MRL HRL Test Result
2015 2015-12-09 20 210 90.7
2015 2015-12-08 20 210 64.4
2015 2015-03-30 20 210 105.5
2015 2015-03-30 20 210 103.1
2013 2013-09-16 20 210 95.2
2013 2013-09-16 20 210 < 20
2013 2013-06-10 20 210 61.3
2013 2013-06-10 20 210 64.8
chloromethane 0.2 2.69 < 0.2 [+] Expand Test Data
Year Test Date MRL HRL Test Result
2015 2015-12-08 0.2 2.69 < 0.2
2015 2015-09-30 0.2 2.69 < 0.2
2015 2015-03-30 0.2 2.69 < 0.2
2013 2013-06-10 0.2 2.69 < 0.2
chromium 0.2 100 0.304 [+] Expand Test Data
Year Test Date MRL HRL Test Result
2013 2013-12-30 0.2 100 0.434
2013 2013-12-30 0.2 100 0.46
2013 2013-09-16 0.2 100 0.392
2013 2013-09-16 0.2 100 0.842
2013 2013-06-10 0.2 100 < 0.2
2013 2013-06-10 0.2 100 < 0.2
2013 2013-04-02 0.2 100 < 0.2
Halon 1011 0.06 90 < 0.06 [+] Expand Test Data
Year Test Date MRL HRL Test Result
2015 2015-12-08 0.06 90 < 0.06
2015 2015-09-30 0.06 90 < 0.06
2015 2015-03-30 0.06 90 < 0.06
2013 2013-06-10 0.06 90 < 0.06
HCFC-22 0.08 0 < 0.08 [+] Expand Test Data
Year Test Date MRL HRL Test Result
2015 2015-12-08 0.08 0 < 0.08
2015 2015-09-30 0.08 0 < 0.08
2015 2015-03-30 0.08 0 < 0.08
2013 2013-06-10 0.08 0 < 0.08

Lead and Copper Data


Lead and copper are recorded separately from other contaminants because of the Lead and Copper Rule. As with all other results, these are the findings at the water supply level. Lead and copper can be — and often are — deposited in drinking water in between the water facility and your tap.

Sample ID Contaminant Sampling Start Date Sampling End Date Result
UT32452 lead 2015-01-01 2017-12-31 0.005mg/L
UT29253 lead 2012-01-01 2014-12-31 0.0021mg/L
UT27270 lead 2011-01-01 2013-12-31 0.0017mg/L
UT22106 lead 2008-01-01 2010-12-31 0.003mg/L

Violations


Known violations of the Safe Drinking Water Act as recorded by the EPA.

Compliance Dates Rule Violation Type Contaminant Name Status
2017-09-01 - 2017-09-30 Revised Total Coliform Rule Monitoring, Routine (RTCR) Revised Total Coliform Rule Returned to Compliance
2004-09-01 - 2004-09-30 Total Coliform Rule Maximum Contaminant Level Violation, Monthly (TCR) Coliform (TCR) Returned to Compliance
2003-09-01 - 2003-09-30 Total Coliform Rule Maximum Contaminant Level Violation, Monthly (TCR) Coliform (TCR) Returned to Compliance
- N/A Inorganic Chemicals Monitoring, Regular Mercury Known
- N/A Inorganic Chemicals Monitoring, Regular Fluoride Known
- N/A Inorganic Chemicals Monitoring, Regular Mercury Known
- N/A Inorganic Chemicals Monitoring, Regular Mercury Known
- N/A Inorganic Chemicals Monitoring, Regular Mercury Known
- N/A Inorganic Chemicals Monitoring, Regular Mercury Known
- N/A Inorganic Chemicals Monitoring, Regular Mercury Known
- N/A Inorganic Chemicals Monitoring, Regular Mercury Known
- N/A Radionuclides Monitoring, Regular Gross Alpha, Excl. Radon and U Known
- N/A Radionuclides Monitoring, Regular Gross Alpha, Excl. Radon and U Known
- N/A Radionuclides Monitoring, Regular Gross Alpha, Excl. Radon and U Known
- N/A Radionuclides Monitoring, Regular Gross Alpha, Excl. Radon and U Known
- N/A Inorganic Chemicals Monitoring, Regular Fluoride Known
- N/A Inorganic Chemicals Monitoring, Regular Fluoride Known
- N/A Inorganic Chemicals Monitoring, Regular Fluoride Known
- N/A Inorganic Chemicals Monitoring, Regular Fluoride Known
- N/A Inorganic Chemicals Monitoring, Regular Fluoride Known
- N/A Nitrates Monitoring, Regular Nitrate Known
- N/A Inorganic Chemicals Monitoring, Regular Selenium Known
- N/A Inorganic Chemicals Monitoring, Regular Selenium Known
- N/A Inorganic Chemicals Monitoring, Regular Selenium Known
- N/A Inorganic Chemicals Monitoring, Regular Selenium Known
- N/A Inorganic Chemicals Monitoring, Regular Selenium Known
- N/A Inorganic Chemicals Monitoring, Regular Selenium Known
- N/A Inorganic Chemicals Monitoring, Regular Selenium Known
- N/A Inorganic Chemicals Monitoring, Regular Selenium Known
- N/A Inorganic Chemicals Monitoring, Regular Mercury Known
- N/A Nitrates Monitoring, Regular Nitrate Known
- N/A Nitrates Monitoring, Regular Nitrate Known
- N/A Nitrates Monitoring, Regular Nitrate Known
- N/A Nitrates Monitoring, Regular Nitrate Known
- N/A Nitrates Monitoring, Regular Nitrate Known
- N/A Nitrates Monitoring, Regular Nitrate Known
- N/A Nitrates Monitoring, Regular Nitrate Known
- N/A Inorganic Chemicals Monitoring, Regular Barium Known
- N/A Inorganic Chemicals Monitoring, Regular Cadmium Known
- N/A Inorganic Chemicals Monitoring, Regular Barium Known
- N/A Inorganic Chemicals Monitoring, Regular Barium Known
- N/A Inorganic Chemicals Monitoring, Regular Barium Known
- N/A Inorganic Chemicals Monitoring, Regular Barium Known
- N/A Inorganic Chemicals Monitoring, Regular Barium Known
- N/A Inorganic Chemicals Monitoring, Regular Barium Known
- N/A Inorganic Chemicals Monitoring, Regular Barium Known
- N/A Inorganic Chemicals Monitoring, Regular Cadmium Known
- N/A Arsenic Monitoring, Regular Arsenic Known
- N/A Arsenic Monitoring, Regular Arsenic Known
- N/A Arsenic Monitoring, Regular Arsenic Known
- N/A Arsenic Monitoring, Regular Arsenic Known
- N/A Arsenic Monitoring, Regular Arsenic Known
- N/A Arsenic Monitoring, Regular Arsenic Known
- N/A Arsenic Monitoring, Regular Arsenic Known
- N/A Inorganic Chemicals Monitoring, Regular Chromium Known
- N/A Inorganic Chemicals Monitoring, Regular Fluoride Known
- N/A Inorganic Chemicals Monitoring, Regular Fluoride Known
- N/A Inorganic Chemicals Monitoring, Regular Chromium Known
- N/A Inorganic Chemicals Monitoring, Regular Chromium Known
- N/A Inorganic Chemicals Monitoring, Regular Chromium Known
- N/A Inorganic Chemicals Monitoring, Regular Chromium Known
- N/A Inorganic Chemicals Monitoring, Regular Chromium Known
- N/A Inorganic Chemicals Monitoring, Regular Chromium Known
- N/A Arsenic Monitoring, Regular Arsenic Known
- N/A Inorganic Chemicals Monitoring, Regular Chromium Known
- N/A Inorganic Chemicals Monitoring, Regular Cadmium Known
- N/A Inorganic Chemicals Monitoring, Regular Cadmium Known
- N/A Inorganic Chemicals Monitoring, Regular Cadmium Known
- N/A Inorganic Chemicals Monitoring, Regular Cadmium Known
- N/A Inorganic Chemicals Monitoring, Regular Cadmium Known
- N/A Inorganic Chemicals Monitoring, Regular Cadmium Known

Local Water Testing


Find a lab in your area so you can get your tap or well water tested. This list contains both governmental and private labs, all of which are EPA-certified for drinking water testing.

Lab Location Zip Code
American West Analytical Lab Salt Lake City, UT 84119

Water Bill Information


Convenient information about your water service.

Unable to identify any billing information about South Jordan City (UTAH18023).

What My Water Data Means


Water data isn't always easy to interpret, but by following the links on this page you should be able to have most of your questions answered. By clicking the name of a water contaminant or secondary substance you can learn about that specific substance. Ultimately this page should give you some insight towards learning if your water is safe, what water filter you should buy (if any), and how well your local water compares against other sources.

Sources


The origin of MyTapWater.org's water data is explained on our Data Sources page.

Why Is My Water Data Not More Recent?


The recency of the data for your ZIP code depends on the last your water source was tested, by a federal, state, or local agency. More information about the timing can be determined by learning about the dataset in question and seeing how often the EPA (other another governing body) mandated testing.