ZAPATA COUNTY WATERWORKS SWTP Water System

MyTapWater.org's tap water quality report is the compilation of data collected from federal, state, and local government agencies, most prominently the EPA. We strive to populate the report with the latest data concerning water contaminants, lead and copper levels, and water quality violations. We only collect drinking water data from public water systems.

PWS Service Information
PWS ID: TX2530002
Type: Community water system
EPA Region: 06
Primary Service Area: Residential Area
Primary Source: Surface water
Population Served: 12,060
Contact Information
RATHMELL, JOSEPH
RATHMELL, JOSEPH
200 E 7TH AVE STE 115
ZAPATA, TX 78076-2944

This public water system services 1 municipality in 1 county.

Summary Results


A summary view of tests in which a water contaminant found to exceed the Maximum Contaminant Level (MCL) set by the EPA.

Maximum Contaminant Levels Exceeded (by year):

2013   (0) 2014   (2) 2015   (2) 2016   (0) 2017   (0) 2018   (0)
chlorate
strontium
chlorate
strontium

Contaminant Detailed Results


This a view of violations of maximum contaminant levels. Use the expanded view see result data for a drinking water contaminant, the minimum level that can be recognized in a test (MRL), and upper limit that is considered healthy (HRL).

chlorate

Year Test Date MRLMinimum Reporting Level HRLHealth Risk Limit Test Result
2015 2015-09-16 20 210 209
2015 2015-09-16 20 210 202
2015 2015-06-08 20 210 236
2015 2015-06-08 20 210 325
2015 2015-03-10 20 210 722
2015 2015-03-10 20 210 718
2014 2014-12-10 20 210 265
2014 2014-12-10 20 210 281

strontium

Year Test Date MRLMinimum Reporting Level HRLHealth Risk Limit Test Result
2015 2015-09-16 0.3 1500 1290
2015 2015-09-16 0.3 1500 1300
2015 2015-06-08 0.3 1500 1030
2015 2015-06-08 0.3 1500 1060
2015 2015-03-10 0.3 1500 1500
2015 2015-03-10 0.3 1500 1590
2014 2014-12-10 0.3 1500 1440
2014 2014-12-10 0.3 1500 1550

Other Water Contaminants Tested


The following contaminants were tested and found to be within national EPA guidelines.

Contaminant MRLMinimum Reporting Level HRLHealth Risk Limit Avg Result
chromium 0.2 100 0.1106 [+] Expand Test Data
Year Test Date MRL HRL Test Result
2015 2015-09-16 0.2 100 < 0.2
2015 2015-09-16 0.2 100 < 0.2
2015 2015-06-08 0.2 100 < 0.2
2015 2015-06-08 0.2 100 < 0.2
2015 2015-03-10 0.2 100 0.429
2015 2015-03-10 0.2 100 0.456
2014 2014-12-10 0.2 100 < 0.2
2014 2014-12-10 0.2 100 < 0.2
chromium-6 0.03 0 0.0658 [+] Expand Test Data
Year Test Date MRL HRL Test Result
2015 2015-09-16 0.03 0 < 0.03
2015 2015-09-16 0.03 0 < 0.03
2015 2015-06-08 0.03 0 < 0.03
2015 2015-06-08 0.03 0 < 0.03
2015 2015-03-10 0.03 0 0.255
2015 2015-03-10 0.03 0 0.271
2014 2014-12-10 0.03 0 < 0.03
2014 2014-12-10 0.03 0 < 0.03
cobalt 1 70 < 1 [+] Expand Test Data
Year Test Date MRL HRL Test Result
2015 2015-09-16 1 70 < 1
2015 2015-09-16 1 70 < 1
2015 2015-06-08 1 70 < 1
2015 2015-06-08 1 70 < 1
2015 2015-03-10 1 70 < 1
2015 2015-03-10 1 70 < 1
2014 2014-12-10 1 70 < 1
2014 2014-12-10 1 70 < 1
molybdenum 1 40 4.6563 [+] Expand Test Data
Year Test Date MRL HRL Test Result
2015 2015-09-16 1 40 5.18
2015 2015-09-16 1 40 5.29
2015 2015-06-08 1 40 3.22
2015 2015-06-08 1 40 3.44
2015 2015-03-10 1 40 5.32
2015 2015-03-10 1 40 5.41
2014 2014-12-10 1 40 4.73
2014 2014-12-10 1 40 4.66
vanadium 0.2 21 3.8288 [+] Expand Test Data
Year Test Date MRL HRL Test Result
2015 2015-09-16 0.2 21 3.68
2015 2015-09-16 0.2 21 3.67
2015 2015-06-08 0.2 21 4.61
2015 2015-06-08 0.2 21 4.58
2015 2015-03-10 0.2 21 2.8
2015 2015-03-10 0.2 21 2.95
2014 2014-12-10 0.2 21 4.18
2014 2014-12-10 0.2 21 4.16
1,1-dichloroethane 0.03 6.14 < 0.03 [+] Expand Test Data
Year Test Date MRL HRL Test Result
2015 2015-09-16 0.03 6.14 < 0.03
2015 2015-06-08 0.03 6.14 < 0.03
2015 2015-03-10 0.03 6.14 < 0.03
2014 2014-12-10 0.03 6.14 < 0.03
1,2,3-trichloropropane 0.03 0.0004 < 0.03 [+] Expand Test Data
Year Test Date MRL HRL Test Result
2015 2015-09-16 0.03 0.0004 < 0.03
2015 2015-06-08 0.03 0.0004 < 0.03
2015 2015-03-10 0.03 0.0004 < 0.03
2014 2014-12-10 0.03 0.0004 < 0.03
1,3-butadiene 0.1 0.0103 < 0.1 [+] Expand Test Data
Year Test Date MRL HRL Test Result
2015 2015-09-16 0.1 0.0103 < 0.1
2015 2015-06-08 0.1 0.0103 < 0.1
2015 2015-03-10 0.1 0.0103 < 0.1
2014 2014-12-10 0.1 0.0103 < 0.1
1,4-dioxane 0.07 0.35 < 0.07 [+] Expand Test Data
Year Test Date MRL HRL Test Result
2015 2015-09-16 0.07 0.35 < 0.07
2015 2015-06-08 0.07 0.35 < 0.07
2015 2015-03-10 0.07 0.35 < 0.07
2014 2014-12-10 0.07 0.35 < 0.07
bromomethane 0.2 140 < 0.2 [+] Expand Test Data
Year Test Date MRL HRL Test Result
2015 2015-09-16 0.2 140 < 0.2
2015 2015-06-08 0.2 140 < 0.2
2015 2015-03-10 0.2 140 < 0.2
2014 2014-12-10 0.2 140 < 0.2
chloromethane 0.2 2.69 < 0.2 [+] Expand Test Data
Year Test Date MRL HRL Test Result
2015 2015-09-16 0.2 2.69 < 0.2
2015 2015-06-08 0.2 2.69 < 0.2
2015 2015-03-10 0.2 2.69 < 0.2
2014 2014-12-10 0.2 2.69 < 0.2
Halon 1011 0.06 90 < 0.06 [+] Expand Test Data
Year Test Date MRL HRL Test Result
2015 2015-09-16 0.06 90 < 0.06
2015 2015-06-08 0.06 90 < 0.06
2015 2015-03-10 0.06 90 < 0.06
2014 2014-12-10 0.06 90 < 0.06
HCFC-22 0.08 0 < 0.08 [+] Expand Test Data
Year Test Date MRL HRL Test Result
2015 2015-09-16 0.08 0 < 0.08
2015 2015-06-08 0.08 0 < 0.08
2015 2015-03-10 0.08 0 < 0.08
2014 2014-12-10 0.08 0 < 0.08
PFBS 0.09 0 < 0.09 [+] Expand Test Data
Year Test Date MRL HRL Test Result
2015 2015-09-16 0.09 0 < 0.09
2015 2015-06-08 0.09 0 < 0.09
2015 2015-03-10 0.09 0 < 0.09
2014 2014-12-10 0.09 0 < 0.09
PFHpA 0.01 0 < 0.01 [+] Expand Test Data
Year Test Date MRL HRL Test Result
2015 2015-09-16 0.01 0 < 0.01
2015 2015-06-08 0.01 0 < 0.01
2015 2015-03-10 0.01 0 < 0.01
2014 2014-12-10 0.01 0 < 0.01
PFHxS 0.03 0 < 0.03 [+] Expand Test Data
Year Test Date MRL HRL Test Result
2015 2015-09-16 0.03 0 < 0.03
2015 2015-06-08 0.03 0 < 0.03
2015 2015-03-10 0.03 0 < 0.03
2014 2014-12-10 0.03 0 < 0.03
PFNA 0.02 0 < 0.02 [+] Expand Test Data
Year Test Date MRL HRL Test Result
2015 2015-09-16 0.02 0 < 0.02
2015 2015-06-08 0.02 0 < 0.02
2015 2015-03-10 0.02 0 < 0.02
2014 2014-12-10 0.02 0 < 0.02
PFOA 0.02 0.07 < 0.02 [+] Expand Test Data
Year Test Date MRL HRL Test Result
2015 2015-09-16 0.02 0.07 < 0.02
2015 2015-06-08 0.02 0.07 < 0.02
2015 2015-03-10 0.02 0.07 < 0.02
2014 2014-12-10 0.02 0.07 < 0.02
PFOS 0.04 0.07 < 0.04 [+] Expand Test Data
Year Test Date MRL HRL Test Result
2015 2015-09-16 0.04 0.07 < 0.04
2015 2015-06-08 0.04 0.07 < 0.04
2015 2015-03-10 0.04 0.07 < 0.04
2014 2014-12-10 0.04 0.07 < 0.04

Lead and Copper Data


Lead and copper are recorded separately from other contaminants because of the Lead and Copper Rule. As with all other results, these are the findings at the water supply level. Lead and copper can be — and often are — deposited in drinking water in between the water facility and your tap.

Sample ID Contaminant Sampling Start Date Sampling End Date Result
TX100330 lead 2014-01-01 2016-12-31 0.0012mg/L
TX80623 lead 2011-01-01 2013-12-31 0.0025mg/L
TX54420 lead 2008-01-01 2010-12-31 0.00297mg/L
TX77180 lead 2008-01-01 2010-12-31 0.00297mg/L

Violations


Known violations of the Safe Drinking Water Act as recorded by the EPA.

Compliance Dates Rule Violation Type Contaminant Name Status
2010-08-01 - 2010-08-31 Long Term 1 Enhanced Surface Water Treatment Rule Monthly Turbidity Exceed (Enhanced SWTR) Interim Enhanced Surfsce Water Treatment Rule Returned to Compliance
2010-08-01 - 2010-08-31 Long Term 1 Enhanced Surface Water Treatment Rule Single Turbidity Exceed (Enhanced SWTR) Interim Enhanced Surfsce Water Treatment Rule Returned to Compliance
2006-01-01 - 2006-03-31 Stage 1 Disinfectants and Disinfection Byproducts Rule Maximum Contaminant Level Violation, Average TTHM Returned to Compliance
2005-10-01 - 2005-12-31 Stage 1 Disinfectants and Disinfection Byproducts Rule Maximum Contaminant Level Violation, Average Total Haloacetic Acids (HAA5) Returned to Compliance
2005-10-01 - 2005-12-31 Stage 1 Disinfectants and Disinfection Byproducts Rule Maximum Contaminant Level Violation, Average TTHM Returned to Compliance
2005-07-01 - 2005-09-30 Stage 1 Disinfectants and Disinfection Byproducts Rule Maximum Contaminant Level Violation, Average Total Haloacetic Acids (HAA5) Returned to Compliance
2005-07-01 - 2005-09-30 Stage 1 Disinfectants and Disinfection Byproducts Rule Maximum Contaminant Level Violation, Average TTHM Returned to Compliance
2005-04-01 - 2005-06-30 Stage 1 Disinfectants and Disinfection Byproducts Rule Maximum Contaminant Level Violation, Average Total Haloacetic Acids (HAA5) Returned to Compliance
2005-04-01 - 2005-06-30 Stage 1 Disinfectants and Disinfection Byproducts Rule Maximum Contaminant Level Violation, Average TTHM Returned to Compliance
2005-01-01 - 2005-03-31 Stage 1 Disinfectants and Disinfection Byproducts Rule Maximum Contaminant Level Violation, Average Total Haloacetic Acids (HAA5) Returned to Compliance
2005-01-01 - 2005-03-31 Stage 1 Disinfectants and Disinfection Byproducts Rule Maximum Contaminant Level Violation, Average TTHM Returned to Compliance
2004-10-01 - 2004-12-31 Stage 1 Disinfectants and Disinfection Byproducts Rule Maximum Contaminant Level Violation, Average Total Haloacetic Acids (HAA5) Returned to Compliance
2004-10-01 - 2004-12-31 Stage 1 Disinfectants and Disinfection Byproducts Rule Maximum Contaminant Level Violation, Average TTHM Returned to Compliance
2004-07-01 - 2004-09-30 Stage 1 Disinfectants and Disinfection Byproducts Rule Maximum Contaminant Level Violation, Average Total Haloacetic Acids (HAA5) Returned to Compliance
2004-07-01 - 2004-09-30 Stage 1 Disinfectants and Disinfection Byproducts Rule Maximum Contaminant Level Violation, Average TTHM Returned to Compliance
2004-04-01 - 2004-06-30 Stage 1 Disinfectants and Disinfection Byproducts Rule Maximum Contaminant Level Violation, Average TTHM Returned to Compliance
2004-04-01 - 2004-06-30 Stage 1 Disinfectants and Disinfection Byproducts Rule Maximum Contaminant Level Violation, Average Total Haloacetic Acids (HAA5) Returned to Compliance
2003-05-01 - 2003-05-31 Surface Water Treatment Rule Monitoring of Treatment (SWTR-Filter) Surface Water Treatment Rule Returned to Compliance
- N/A Lead and Copper Rule Initial Tap Sampling for Pb and Cu Lead and Copper Rule Returned to Compliance

Local Water Testing


Find a lab in your area so you can get your tap or well water tested. This list contains both governmental and private labs, all of which are EPA-certified for drinking water testing.

Lab Location Zip Code
City of Laredo Health Department Lab Laredo, TX 78040
City of Kerrville Laboratory Kerrville, TX 78028
Guadalupe – Blanco River Authority Regional Laboratory Seguin, TX 78155

Water Bill Information


Convenient information about your water service.

Unable to identify any billing information about ZAPATA COUNTY WATERWORKS SWTP (TX2530002).

What My Water Data Means


Water data isn't always easy to interpret, but by following the links on this page you should be able to have most of your questions answered. By clicking the name of a water contaminant or secondary substance you can learn about that specific substance. Ultimately this page should give you some insight towards learning if your water is safe, what water filter you should buy (if any), and how well your local water compares against other sources.

Sources


The origin of MyTapWater.org's water data is explained on our Data Sources page.

Why Is My Water Data Not More Recent?


The recency of the data for your ZIP code depends on the last your water source was tested, by a federal, state, or local agency. More information about the timing can be determined by learning about the dataset in question and seeing how often the EPA (other another governing body) mandated testing.