Whitewood Water System

MyTapWater.org's tap water quality report is the compilation of data collected from federal, state, and local government agencies, most prominently the EPA. We strive to populate the report with the latest data concerning water contaminants, lead and copper levels, and water quality violations. We only collect drinking water data from public water systems.

PWS Service Information
PWS ID: SD4600368
Type: Community water system
EPA Region: 08
Primary Service Area: Municipality
Primary Source: Ground water
Population Served: 927
Contact Information
WHITEWOOD
DAVID WERLINGER
1025 MEADE STREET
WHITEWOOD, SD 57793
[email protected]

This public water system services 1 municipality in 1 county.

We could not find test result data for Whitewood.
However, this area is serviced by 4 or more other public water systems. Check your water bill to see which specific system applies. Here is a list of related systems:

Summary Results


A summary view of tests in which a water contaminant found to exceed the Maximum Contaminant Level (MCL) set by the EPA.

We couldn't find any records of contaminants exceeding the regulated limits in your water.

Other Water Contaminants Tested


The following contaminants were tested and found to be within national EPA guidelines.

We couldn't find any records of contaminants in your water.

Lead and Copper Data


Lead and copper are recorded separately from other contaminants because of the Lead and Copper Rule. As with all other results, these are the findings at the water supply level. Lead and copper can be — and often are — deposited in drinking water in between the water facility and your tap.

Sample ID Contaminant Sampling Start Date Sampling End Date Result
10107 lead 2018-01-01 2018-12-31 0.002mg/L
10095 lead 2015-01-01 2015-12-31 0.003mg/L
10083 lead 2012-01-01 2012-12-31 0.002mg/L
10071 lead 2009-01-01 2009-12-31 0.007mg/L

Violations


Known violations of the Safe Drinking Water Act as recorded by the EPA.

Compliance Dates Rule Violation Type Contaminant Name Status
- N/A Nitrates Monitoring, Regular Nitrate Returned to Compliance
- N/A Synthetic Organic Chemicals Monitoring, Regular ETHYLENE DIBROMIDE Known
- N/A Inorganic Chemicals Monitoring, Regular Fluoride Returned to Compliance
- N/A Synthetic Organic Chemicals Monitoring, Regular Glyphosate Known
- N/A Radionuclides Monitoring, Regular Gross Alpha, Excl. Radon and U Known
- N/A Synthetic Organic Chemicals Monitoring, Regular Heptachlor Known
- N/A Synthetic Organic Chemicals Monitoring, Regular Heptachlor epoxide Known
- N/A Synthetic Organic Chemicals Monitoring, Regular HEXACHLOROBENZENE Known
- N/A Synthetic Organic Chemicals Monitoring, Regular Hexachlorocyclopentadiene Known
- N/A Synthetic Organic Chemicals Monitoring, Regular LASSO Known
- N/A Inorganic Chemicals Monitoring, Regular Mercury Returned to Compliance
- N/A Synthetic Organic Chemicals Monitoring, Regular Methoxychlor Known
- N/A Synthetic Organic Chemicals Monitoring, Regular Endrin Known
- N/A Synthetic Organic Chemicals Monitoring, Regular OXAMYL Known
- N/A Synthetic Organic Chemicals Monitoring, Regular Pentachlorophenol Known
- N/A Synthetic Organic Chemicals Monitoring, Regular Picloram Known
- N/A Inorganic Chemicals Monitoring, Regular Selenium Returned to Compliance
- N/A Synthetic Organic Chemicals Monitoring, Regular Simazine Known
- N/A Synthetic Organic Chemicals Monitoring, Regular Total Polychlorinated Biphenyls (PCB) Known
- N/A Synthetic Organic Chemicals Monitoring, Regular Toxaphene Known
- N/A Miscellaneous Notification, Public - Known
- N/A Lead and Copper Rule Initial Tap Sampling for Pb and Cu Lead and Copper Rule Returned to Compliance
- N/A Lead and Copper Rule Follow-up Or Routine LCR Tap M/R Lead and Copper Rule Returned to Compliance
- N/A Inorganic Chemicals Monitoring, Regular Cadmium Returned to Compliance
- N/A Synthetic Organic Chemicals Monitoring, Regular 2,4-D Known
- N/A Synthetic Organic Chemicals Monitoring, Regular 2,4,5-TP Known
- N/A Synthetic Organic Chemicals Monitoring, Regular Aldicarb Known
- N/A Synthetic Organic Chemicals Monitoring, Regular Aldicarb sulfone Known
- N/A Synthetic Organic Chemicals Monitoring, Regular Aldicarb sulfoxide Known
- N/A Arsenic Monitoring, Regular Arsenic Returned to Compliance
- N/A Synthetic Organic Chemicals Monitoring, Regular Atrazine Known
- N/A Inorganic Chemicals Monitoring, Regular Barium Returned to Compliance
- N/A Synthetic Organic Chemicals Monitoring, Regular Benzo(a)pyrene Known
- N/A Synthetic Organic Chemicals Monitoring, Regular BHC-GAMMA Known
- N/A Synthetic Organic Chemicals Monitoring, Regular 1,2-DIBROMO-3-CHLOROPROPANE Known
- N/A Synthetic Organic Chemicals Monitoring, Regular Carbofuran Known
- N/A Synthetic Organic Chemicals Monitoring, Regular Chlordane Known
- N/A Inorganic Chemicals Monitoring, Regular Chromium Returned to Compliance
- N/A Radionuclides Monitoring, Regular Combined Radium (-226 and -228) Known
- N/A Synthetic Organic Chemicals Monitoring, Regular Dalapon Known
- N/A Synthetic Organic Chemicals Monitoring, Regular Di(2-ethylhexyl) adipate Known
- N/A Synthetic Organic Chemicals Monitoring, Regular Di(2-ethylhexyl) phthalate Known
- N/A Synthetic Organic Chemicals Monitoring, Regular Dinoseb Known
- N/A Synthetic Organic Chemicals Monitoring, Regular Diquat Known
- N/A Synthetic Organic Chemicals Monitoring, Regular Endothall Known

Local Water Testing


Find a lab in your area so you can get your tap or well water tested. This list contains both governmental and private labs, all of which are EPA-certified for drinking water testing.

Unable to identify any nearby water testing labs near 57793.

Water Bill Information


Convenient information about your water service.

Unable to identify any billing information about Whitewood (SD4600368).

What My Water Data Means


Water data isn't always easy to interpret, but by following the links on this page you should be able to have most of your questions answered. By clicking the name of a water contaminant or secondary substance you can learn about that specific substance. Ultimately this page should give you some insight towards learning if your water is safe, what water filter you should buy (if any), and how well your local water compares against other sources.

Sources


The origin of MyTapWater.org's water data is explained on our Data Sources page.

Why Is My Water Data Not More Recent?


The recency of the data for your ZIP code depends on the last your water source was tested, by a federal, state, or local agency. More information about the timing can be determined by learning about the dataset in question and seeing how often the EPA (other another governing body) mandated testing.