Watertown Municipal Utilities Water System

MyTapWater.org's tap water quality report is the compilation of data collected from federal, state, and local government agencies, most prominently the EPA. We strive to populate the report with the latest data concerning water contaminants, lead and copper levels, and water quality violations. We only collect drinking water data from public water systems.

PWS Service Information
PWS ID: SD4600356
Type: Community water system
EPA Region: 08
Primary Service Area: Homeowners Association
Primary Source: Ground water
Population Served: 21,482
Contact Information
WATERTOWN MUNICIPAL UTILITIES
JEFF DEVILLE
901 FOURTH AVE SW
WATERTOWN, SD 57201
[email protected]

This public water system services 1 municipality in 1 county.

Summary Results


A summary view of tests in which a water contaminant found to exceed the Maximum Contaminant Level (MCL) set by the EPA.

Maximum Contaminant Levels Exceeded (by year):

Contaminant Detailed Results


This a view of violations of maximum contaminant levels. Use the expanded view see result data for a drinking water contaminant, the minimum level that can be recognized in a test (MRL), and upper limit that is considered healthy (HRL).

1-butanol

Year Test Date MRLMinimum Reporting Level HRLHealth Risk Limit Test Result
2018 2018-04-18 2 0.00 < 2

2-methoxyethanol

Year Test Date MRLMinimum Reporting Level HRLHealth Risk Limit Test Result
2018 2018-04-18 0.4 0.00 < 0.4

2-propen-1-ol

Year Test Date MRLMinimum Reporting Level HRLHealth Risk Limit Test Result
2018 2018-04-18 0.5 0.00 < 0.5

alpha-hexachlorocyclohexane

Year Test Date MRLMinimum Reporting Level HRLHealth Risk Limit Test Result
2018 2018-04-18 0.01 0.00 < 0.01

butylated hydroxyanisole

Year Test Date MRLMinimum Reporting Level HRLHealth Risk Limit Test Result
2018 2018-04-18 0.03 0.00 < 0.03

chlorpyrifos

Year Test Date MRLMinimum Reporting Level HRLHealth Risk Limit Test Result
2018 2018-04-18 0.03 0.00 < 0.03

dimethipin

Year Test Date MRLMinimum Reporting Level HRLHealth Risk Limit Test Result
2018 2018-04-18 0.2 0.00 < 0.2

ethoprop

Year Test Date MRLMinimum Reporting Level HRLHealth Risk Limit Test Result
2018 2018-04-18 0.03 0.00 < 0.03

germanium

Year Test Date MRLMinimum Reporting Level HRLHealth Risk Limit Test Result
2018 2018-04-18 0.3 0.00 < 0.3

manganese

Year Test Date MRLMinimum Reporting Level HRLHealth Risk Limit Test Result
2018 2018-04-18 0.4 0.00 4.647

o-toluidine

Year Test Date MRLMinimum Reporting Level HRLHealth Risk Limit Test Result
2018 2018-04-18 0.007 0.00 < 0.007

oxyfluorfen

Year Test Date MRLMinimum Reporting Level HRLHealth Risk Limit Test Result
2018 2018-04-18 0.05 0.00 < 0.05

profenofos

Year Test Date MRLMinimum Reporting Level HRLHealth Risk Limit Test Result
2018 2018-04-18 0.3 0.00 < 0.3

quinoline

Year Test Date MRLMinimum Reporting Level HRLHealth Risk Limit Test Result
2018 2018-04-18 0.02 0.00 < 0.02

tebuconazole

Year Test Date MRLMinimum Reporting Level HRLHealth Risk Limit Test Result
2018 2018-04-18 0.2 0.00 < 0.2

total permethrin

Year Test Date MRLMinimum Reporting Level HRLHealth Risk Limit Test Result
2018 2018-04-18 0.04 0.00 < 0.04

tribufos

Year Test Date MRLMinimum Reporting Level HRLHealth Risk Limit Test Result
2018 2018-04-18 0.07 0.00 < 0.07

HAA5

Year Test Date MRLMinimum Reporting Level HRLHealth Risk Limit Test Result
2018 2018-04-18 0 0.00 12.831
2018 2018-04-18 0 0.00 8.533
2018 2018-04-18 0 0.00 10.206
2018 2018-04-18 0 0.00 8.542

HAA6Br

Year Test Date MRLMinimum Reporting Level HRLHealth Risk Limit Test Result
2018 2018-04-18 0 0.00 16.761
2018 2018-04-18 0 0.00 12.703
2018 2018-04-18 0 0.00 14.613
2018 2018-04-18 0 0.00 12.62

HAA9

Year Test Date MRLMinimum Reporting Level HRLHealth Risk Limit Test Result
2018 2018-04-18 0 0.00 25.543
2018 2018-04-18 0 0.00 18.016
2018 2018-04-18 0 0.00 21.129
2018 2018-04-18 0 0.00 17.957

chlorate

Year Test Date MRLMinimum Reporting Level HRLHealth Risk Limit Test Result
2014 2014-11-12 20 210 176.585
2014 2014-11-12 20 210 166.169
2014 2014-05-05 20 210 221.339
2014 2014-05-05 20 210 240.302

Other Water Contaminants Tested


The following contaminants were tested and found to be within national EPA guidelines.

Contaminant MRLMinimum Reporting Level HRLHealth Risk Limit Avg Result
chromium 0.2 100 0.6168 [+] Expand Test Data
Year Test Date MRL HRL Test Result
2014 2014-11-12 0.2 100 0.841
2014 2014-11-12 0.2 100 0.959
2014 2014-05-05 0.2 100 0.364
2014 2014-05-05 0.2 100 0.303
chromium-6 0.03 0 0.5863 [+] Expand Test Data
Year Test Date MRL HRL Test Result
2014 2014-11-12 0.03 0 0.807
2014 2014-11-12 0.03 0 0.889
2014 2014-05-05 0.03 0 0.375
2014 2014-05-05 0.03 0 0.274
cobalt 1 70 < 1 [+] Expand Test Data
Year Test Date MRL HRL Test Result
2014 2014-11-12 1 70 < 1
2014 2014-11-12 1 70 < 1
2014 2014-05-05 1 70 < 1
2014 2014-05-05 1 70 < 1
molybdenum 1 40 3.2185 [+] Expand Test Data
Year Test Date MRL HRL Test Result
2014 2014-11-12 1 40 2.994
2014 2014-11-12 1 40 3.238
2014 2014-05-05 1 40 3.238
2014 2014-05-05 1 40 3.404
strontium 0.3 1500 152.6598 [+] Expand Test Data
Year Test Date MRL HRL Test Result
2014 2014-11-12 0.3 1500 149.31
2014 2014-11-12 0.3 1500 168.577
2014 2014-05-05 0.3 1500 144.606
2014 2014-05-05 0.3 1500 148.146
vanadium 0.2 21 2.7405 [+] Expand Test Data
Year Test Date MRL HRL Test Result
2014 2014-11-12 0.2 21 3.027
2014 2014-11-12 0.2 21 2.191
2014 2014-05-05 0.2 21 2.717
2014 2014-05-05 0.2 21 3.027
1,1-dichloroethane 0.03 6.14 < 0.03 [+] Expand Test Data
Year Test Date MRL HRL Test Result
2014 2014-11-12 0.03 6.14 < 0.03
2014 2014-05-05 0.03 6.14 < 0.03
1,2,3-trichloropropane 0.03 0.0004 < 0.03 [+] Expand Test Data
Year Test Date MRL HRL Test Result
2014 2014-11-12 0.03 0.0004 < 0.03
2014 2014-05-05 0.03 0.0004 < 0.03
1,3-butadiene 0.1 0.0103 < 0.1 [+] Expand Test Data
Year Test Date MRL HRL Test Result
2014 2014-11-12 0.1 0.0103 < 0.1
2014 2014-05-05 0.1 0.0103 < 0.1
1,4-dioxane 0.07 0.35 < 0.07 [+] Expand Test Data
Year Test Date MRL HRL Test Result
2014 2014-11-12 0.07 0.35 < 0.07
2014 2014-05-05 0.07 0.35 < 0.07
bromomethane 0.2 140 < 0.2 [+] Expand Test Data
Year Test Date MRL HRL Test Result
2014 2014-11-12 0.2 140 < 0.2
2014 2014-05-05 0.2 140 < 0.2
chloromethane 0.2 2.69 < 0.2 [+] Expand Test Data
Year Test Date MRL HRL Test Result
2014 2014-11-12 0.2 2.69 < 0.2
2014 2014-05-05 0.2 2.69 < 0.2
Halon 1011 0.06 90 < 0.06 [+] Expand Test Data
Year Test Date MRL HRL Test Result
2014 2014-11-12 0.06 90 < 0.06
2014 2014-05-05 0.06 90 < 0.06
HCFC-22 0.08 0 < 0.08 [+] Expand Test Data
Year Test Date MRL HRL Test Result
2014 2014-11-12 0.08 0 < 0.08
2014 2014-05-05 0.08 0 < 0.08
PFBS 0.09 0 < 0.09 [+] Expand Test Data
Year Test Date MRL HRL Test Result
2014 2014-11-12 0.09 0 < 0.09
2014 2014-05-05 0.09 0 < 0.09
PFHpA 0.01 0 < 0.01 [+] Expand Test Data
Year Test Date MRL HRL Test Result
2014 2014-11-12 0.01 0 < 0.01
2014 2014-05-05 0.01 0 < 0.01
PFHxS 0.03 0 < 0.03 [+] Expand Test Data
Year Test Date MRL HRL Test Result
2014 2014-11-12 0.03 0 < 0.03
2014 2014-05-05 0.03 0 < 0.03
PFNA 0.02 0 < 0.02 [+] Expand Test Data
Year Test Date MRL HRL Test Result
2014 2014-11-12 0.02 0 < 0.02
2014 2014-05-05 0.02 0 < 0.02
PFOA 0.02 0.07 < 0.02 [+] Expand Test Data
Year Test Date MRL HRL Test Result
2014 2014-11-12 0.02 0.07 < 0.02
2014 2014-05-05 0.02 0.07 < 0.02
PFOS 0.04 0.07 < 0.04 [+] Expand Test Data
Year Test Date MRL HRL Test Result
2014 2014-11-12 0.04 0.07 < 0.04
2014 2014-05-05 0.04 0.07 < 0.04

Lead and Copper Data


Lead and copper are recorded separately from other contaminants because of the Lead and Copper Rule. As with all other results, these are the findings at the water supply level. Lead and copper can be — and often are — deposited in drinking water in between the water facility and your tap.

Sample ID Contaminant Sampling Start Date Sampling End Date Result
10107 lead 2018-01-01 2018-12-31 0.001mg/L
10095 lead 2015-01-01 2015-12-31 0.001mg/L
10083 lead 2012-01-01 2012-12-31 0.002mg/L
10071 lead 2009-01-01 2009-12-31 0.002mg/L

Violations


Known violations of the Safe Drinking Water Act as recorded by the EPA.

Compliance Dates Rule Violation Type Contaminant Name Status
2016-07-01 - 2016-09-30 Stage 2 Disinfectants and Disinfection Byproducts Rule Maximum Contaminant Level Violation, Average TTHM Known
- N/A Synthetic Organic Chemicals Monitoring, Regular Atrazine Returned to Compliance
- N/A Radionuclides Monitoring, Regular Combined Radium (-226 and -228) Known
- N/A Radionuclides Monitoring, Regular Gross Alpha, Excl. Radon and U Known

Local Water Testing


Find a lab in your area so you can get your tap or well water tested. This list contains both governmental and private labs, all of which are EPA-certified for drinking water testing.

Unable to identify any nearby water testing labs near 57201.

Water Bill Information


Convenient information about your water service.

Unable to identify any billing information about Watertown Municipal Utilities (SD4600356).

What My Water Data Means


Water data isn't always easy to interpret, but by following the links on this page you should be able to have most of your questions answered. By clicking the name of a water contaminant or secondary substance you can learn about that specific substance. Ultimately this page should give you some insight towards learning if your water is safe, what water filter you should buy (if any), and how well your local water compares against other sources.

Sources


The origin of MyTapWater.org's water data is explained on our Data Sources page.

Why Is My Water Data Not More Recent?


The recency of the data for your ZIP code depends on the last your water source was tested, by a federal, state, or local agency. More information about the timing can be determined by learning about the dataset in question and seeing how often the EPA (other another governing body) mandated testing.