Lebanon City Water System

MyTapWater.org's tap water quality report is the compilation of data collected from federal, state, and local government agencies, most prominently the EPA. We strive to populate the report with the latest data concerning water contaminants, lead and copper levels, and water quality violations. We only collect drinking water data from public water systems.

PWS Service Information
PWS ID: OH8304112
Type: Community water system
EPA Region: 05
Primary Service Area: Residential Area
Primary Source: Surface water purchased
Population Served: 20,500
Contact Information
HABIG, JOHN
HABIG, JOHN
600 W. MAIN ST.
LEBANON, OH 45036
[email protected]

This public water system services 1 municipality in 1 county.

Summary Results


A summary view of tests in which a water contaminant found to exceed the Maximum Contaminant Level (MCL) set by the EPA.

Maximum Contaminant Levels Exceeded (by year):

2013   (0) 2014   (1) 2015   (0) 2016   (0) 2017   (0) 2018   (0)
1,4-dioxane

Contaminant Detailed Results


This a view of violations of maximum contaminant levels. Use the expanded view see result data for a drinking water contaminant, the minimum level that can be recognized in a test (MRL), and upper limit that is considered healthy (HRL).

1,4-dioxane

Year Test Date MRLMinimum Reporting Level HRLHealth Risk Limit Test Result
2015 2015-07-08 0.07 0.35 0.098
2015 2015-04-08 0.07 0.35 0.16
2015 2015-01-12 0.07 0.35 0.25
2014 2014-10-08 0.07 0.35 0.77

Other Water Contaminants Tested


The following contaminants were tested and found to be within national EPA guidelines.

Contaminant MRLMinimum Reporting Level HRLHealth Risk Limit Avg Result
1,1-dichloroethane 0.03 6.14 < 0.03 [+] Expand Test Data
Year Test Date MRL HRL Test Result
2015 2015-07-08 0.03 6.14 < 0.03
2015 2015-04-08 0.03 6.14 < 0.03
2015 2015-01-12 0.03 6.14 < 0.03
2014 2014-10-08 0.03 6.14 < 0.03
1,2,3-trichloropropane 0.03 0.0004 < 0.03 [+] Expand Test Data
Year Test Date MRL HRL Test Result
2015 2015-07-08 0.03 0.0004 < 0.03
2015 2015-04-08 0.03 0.0004 < 0.03
2015 2015-01-12 0.03 0.0004 < 0.03
2014 2014-10-08 0.03 0.0004 < 0.03
1,3-butadiene 0.1 0.0103 < 0.1 [+] Expand Test Data
Year Test Date MRL HRL Test Result
2015 2015-07-08 0.1 0.0103 < 0.1
2015 2015-04-08 0.1 0.0103 < 0.1
2015 2015-01-12 0.1 0.0103 < 0.1
2014 2014-10-08 0.1 0.0103 < 0.1
bromomethane 0.2 140 < 0.2 [+] Expand Test Data
Year Test Date MRL HRL Test Result
2015 2015-07-08 0.2 140 < 0.2
2015 2015-04-08 0.2 140 < 0.2
2015 2015-01-12 0.2 140 < 0.2
2014 2014-10-08 0.2 140 < 0.2
chlorate 20 210 19.0875 [+] Expand Test Data
Year Test Date MRL HRL Test Result
2015 2015-07-08 20 210 31.5
2015 2015-07-08 20 210 34.9
2015 2015-04-08 20 210 < 20
2015 2015-04-08 20 210 < 20
2015 2015-01-12 20 210 < 20
2015 2015-01-12 20 210 < 20
2014 2014-10-08 20 210 42.6
2014 2014-10-08 20 210 43.7
chloromethane 0.2 2.69 < 0.2 [+] Expand Test Data
Year Test Date MRL HRL Test Result
2015 2015-07-08 0.2 2.69 < 0.2
2015 2015-04-08 0.2 2.69 < 0.2
2015 2015-01-12 0.2 2.69 < 0.2
2014 2014-10-08 0.2 2.69 < 0.2
chromium 0.2 100 0.1788 [+] Expand Test Data
Year Test Date MRL HRL Test Result
2015 2015-07-08 0.2 100 < 0.2
2015 2015-07-08 0.2 100 0.23
2015 2015-04-08 0.2 100 0.26
2015 2015-04-08 0.2 100 < 0.2
2015 2015-01-12 0.2 100 0.28
2015 2015-01-12 0.2 100 0.21
2014 2014-10-08 0.2 100 0.24
2014 2014-10-08 0.2 100 0.21
chromium-6 0.03 0 0.0779 [+] Expand Test Data
Year Test Date MRL HRL Test Result
2015 2015-07-08 0.03 0 0.065
2015 2015-07-08 0.03 0 0.076
2015 2015-04-08 0.03 0 0.059
2015 2015-04-08 0.03 0 0.06
2015 2015-01-12 0.03 0 0.053
2015 2015-01-12 0.03 0 0.06
2014 2014-10-08 0.03 0 0.14
2014 2014-10-08 0.03 0 0.11
cobalt 1 70 < 1 [+] Expand Test Data
Year Test Date MRL HRL Test Result
2015 2015-07-08 1 70 < 1
2015 2015-07-08 1 70 < 1
2015 2015-04-08 1 70 < 1
2015 2015-04-08 1 70 < 1
2015 2015-01-12 1 70 < 1
2015 2015-01-12 1 70 < 1
2014 2014-10-08 1 70 < 1
2014 2014-10-08 1 70 < 1
Halon 1011 0.06 90 < 0.06 [+] Expand Test Data
Year Test Date MRL HRL Test Result
2015 2015-07-08 0.06 90 < 0.06
2015 2015-04-08 0.06 90 < 0.06
2015 2015-01-12 0.06 90 < 0.06
2014 2014-10-08 0.06 90 < 0.06
HCFC-22 0.08 0 < 0.08 [+] Expand Test Data
Year Test Date MRL HRL Test Result
2015 2015-07-08 0.08 0 < 0.08
2015 2015-04-08 0.08 0 < 0.08
2015 2015-01-12 0.08 0 < 0.08
2014 2014-10-08 0.08 0 < 0.08
molybdenum 1 40 1.4875 [+] Expand Test Data
Year Test Date MRL HRL Test Result
2015 2015-07-08 1 40 1.8
2015 2015-07-08 1 40 2.1
2015 2015-04-08 1 40 < 1
2015 2015-04-08 1 40 < 1
2015 2015-01-12 1 40 1.2
2015 2015-01-12 1 40 1.2
2014 2014-10-08 1 40 2.8
2014 2014-10-08 1 40 2.8
PFBS 0.09 0 < 0.09 [+] Expand Test Data
Year Test Date MRL HRL Test Result
2015 2015-07-08 0.09 0 < 0.09
2015 2015-04-08 0.09 0 < 0.09
2015 2015-01-12 0.09 0 < 0.09
2014 2014-10-08 0.09 0 < 0.09
PFHpA 0.01 0 < 0.01 [+] Expand Test Data
Year Test Date MRL HRL Test Result
2015 2015-07-08 0.01 0 < 0.01
2015 2015-04-08 0.01 0 < 0.01
2015 2015-01-12 0.01 0 < 0.01
2014 2014-10-08 0.01 0 < 0.01
PFHxS 0.03 0 < 0.03 [+] Expand Test Data
Year Test Date MRL HRL Test Result
2015 2015-07-08 0.03 0 < 0.03
2015 2015-04-08 0.03 0 < 0.03
2015 2015-01-12 0.03 0 < 0.03
2014 2014-10-08 0.03 0 < 0.03
PFNA 0.02 0 < 0.02 [+] Expand Test Data
Year Test Date MRL HRL Test Result
2015 2015-07-08 0.02 0 < 0.02
2015 2015-04-08 0.02 0 < 0.02
2015 2015-01-12 0.02 0 < 0.02
2014 2014-10-08 0.02 0 < 0.02
PFOA 0.02 0.07 < 0.02 [+] Expand Test Data
Year Test Date MRL HRL Test Result
2015 2015-07-08 0.02 0.07 < 0.02
2015 2015-04-08 0.02 0.07 < 0.02
2015 2015-01-12 0.02 0.07 < 0.02
2014 2014-10-08 0.02 0.07 < 0.02
PFOS 0.04 0.07 < 0.04 [+] Expand Test Data
Year Test Date MRL HRL Test Result
2015 2015-07-08 0.04 0.07 < 0.04
2015 2015-04-08 0.04 0.07 < 0.04
2015 2015-01-12 0.04 0.07 < 0.04
2014 2014-10-08 0.04 0.07 < 0.04
strontium 0.3 1500 224.125 [+] Expand Test Data
Year Test Date MRL HRL Test Result
2015 2015-07-08 0.3 1500 235
2015 2015-07-08 0.3 1500 264
2015 2015-04-08 0.3 1500 196
2015 2015-04-08 0.3 1500 178
2015 2015-01-12 0.3 1500 225
2015 2015-01-12 0.3 1500 204
2014 2014-10-08 0.3 1500 256
2014 2014-10-08 0.3 1500 235
vanadium 0.2 21 0.1888 [+] Expand Test Data
Year Test Date MRL HRL Test Result
2015 2015-07-08 0.2 21 0.37
2015 2015-07-08 0.2 21 0.41
2015 2015-04-08 0.2 21 < 0.2
2015 2015-04-08 0.2 21 < 0.2
2015 2015-01-12 0.2 21 < 0.2
2015 2015-01-12 0.2 21 < 0.2
2014 2014-10-08 0.2 21 0.23
2014 2014-10-08 0.2 21 0.5

Lead and Copper Data


Lead and copper are recorded separately from other contaminants because of the Lead and Copper Rule. As with all other results, these are the findings at the water supply level. Lead and copper can be — and often are — deposited in drinking water in between the water facility and your tap.

Sample ID Contaminant Sampling Start Date Sampling End Date Result
OH69919 lead 2019-01-01 2019-12-31 0.00076mg/L
OH66457 lead 2018-01-01 2018-12-31 0.00141mg/L
OH62987 lead 2014-01-01 2016-12-31 0mg/L
OH58426 lead 2013-07-01 2013-12-31 0mg/L
OH58014 lead 2013-01-01 2013-06-30 0.00303mg/L
OH56447 lead 2010-01-01 2012-12-31 0.00351mg/L
OH52558 lead 2008-01-01 2010-12-31 0.0075mg/L

Violations


Known violations of the Safe Drinking Water Act as recorded by the EPA.

Compliance Dates Rule Violation Type Contaminant Name Status
2008-01-01 - 2008-12-31 Nitrates Monitoring, Regular Nitrate Returned to Compliance
2008-05-01 - 2008-05-31 Total Coliform Rule Monitoring, Routine Minor (TCR) Coliform (TCR) Returned to Compliance
2006-04-01 - 2006-06-30 Synthetic Organic Chemicals Monitoring, Regular Total Polychlorinated Biphenyls (PCB) Returned to Compliance
2006-04-01 - 2006-06-30 Synthetic Organic Chemicals Monitoring, Regular Methoxychlor Returned to Compliance
2006-04-01 - 2006-06-30 Synthetic Organic Chemicals Monitoring, Regular BHC-GAMMA Returned to Compliance
2004-04-01 - 2004-06-30 Stage 1 Disinfectants and Disinfection Byproducts Rule Monitoring and Reporting (DBP) Total Haloacetic Acids (HAA5) Returned to Compliance
2004-04-01 - 2004-06-30 Stage 1 Disinfectants and Disinfection Byproducts Rule Monitoring and Reporting (DBP) TTHM Known
2004-04-01 - 2004-04-30 Total Coliform Rule Maximum Contaminant Level Violation, Monthly (TCR) Coliform (TCR) Returned to Compliance
- N/A Arsenic Monitoring, Regular Arsenic Returned to Compliance
- N/A Inorganic Chemicals Monitoring, Regular Thallium, Total Returned to Compliance
- N/A Nitrates Monitoring, Regular Nitrate Returned to Compliance
- N/A Inorganic Chemicals Monitoring, Regular Nickel Returned to Compliance
- N/A Inorganic Chemicals Monitoring, Regular Beryllium, Total Returned to Compliance
- N/A Total Coliform Rule Maximum Contaminant Level Violation, Acute (TCR) Coliform (TCR) Returned to Compliance
- N/A Inorganic Chemicals Monitoring, Regular Antimony, Total Returned to Compliance
- N/A Total Coliform Rule Maximum Contaminant Level Violation, Monthly (TCR) Coliform (TCR) Returned to Compliance
- N/A Total Coliform Rule Maximum Contaminant Level Violation, Monthly (TCR) Coliform (TCR) Returned to Compliance
- N/A Total Coliform Rule Maximum Contaminant Level Violation, Acute (TCR) Coliform (TCR) Returned to Compliance

Local Water Testing


Find a lab in your area so you can get your tap or well water tested. This list contains both governmental and private labs, all of which are EPA-certified for drinking water testing.

Unable to identify any nearby water testing labs near 45036.

Water Bill Information


Convenient information about your water service.

Unable to identify any billing information about Lebanon City (OH8304112).

What My Water Data Means


Water data isn't always easy to interpret, but by following the links on this page you should be able to have most of your questions answered. By clicking the name of a water contaminant or secondary substance you can learn about that specific substance. Ultimately this page should give you some insight towards learning if your water is safe, what water filter you should buy (if any), and how well your local water compares against other sources.

Sources


The origin of MyTapWater.org's water data is explained on our Data Sources page.

Why Is My Water Data Not More Recent?


The recency of the data for your ZIP code depends on the last your water source was tested, by a federal, state, or local agency. More information about the timing can be determined by learning about the dataset in question and seeing how often the EPA (other another governing body) mandated testing.