Tallmadge City Pws Water System

MyTapWater.org's tap water quality report is the compilation of data collected from federal, state, and local government agencies, most prominently the EPA. We strive to populate the report with the latest data concerning water contaminants, lead and copper levels, and water quality violations. We only collect drinking water data from public water systems.

PWS Service Information
PWS ID: OH7704703
Type: Community water system
EPA Region: 05
Primary Service Area: Residential Area
Primary Source: Surface water purchased
Population Served: 17,512
Contact Information
GOODRIDGE, JOSH
GOODRIDGE, JOSH
210 OSCEOLA AVE
TALLMADGE, OH 44278
[email protected]

This public water system services 1 municipality in 1 county.

Summary Results


A summary view of tests in which a water contaminant found to exceed the Maximum Contaminant Level (MCL) set by the EPA.

Maximum Contaminant Levels Exceeded (by year):

2013   (1) 2014   (0) 2015   (0) 2016   (0) 2017   (0) 2018   (0)
chlorate

Contaminant Detailed Results


This a view of violations of maximum contaminant levels. Use the expanded view see result data for a drinking water contaminant, the minimum level that can be recognized in a test (MRL), and upper limit that is considered healthy (HRL).

chlorate

Year Test Date MRLMinimum Reporting Level HRLHealth Risk Limit Test Result
2013 2013-11-11 20 210 462
2013 2013-11-11 20 210 596
2013 2013-08-13 20 210 759
2013 2013-08-13 20 210 757
2013 2013-05-13 20 210 451
2013 2013-05-13 20 210 565
2013 2013-02-11 20 210 226
2013 2013-02-11 20 210 299

Other Water Contaminants Tested


The following contaminants were tested and found to be within national EPA guidelines.

Contaminant MRLMinimum Reporting Level HRLHealth Risk Limit Avg Result
1,1-dichloroethane 0.03 6.14 < 0.03 [+] Expand Test Data
Year Test Date MRL HRL Test Result
2013 2013-11-11 0.03 6.14 < 0.03
2013 2013-08-13 0.03 6.14 < 0.03
2013 2013-05-13 0.03 6.14 < 0.03
2013 2013-02-11 0.03 6.14 < 0.03
1,2,3-trichloropropane 0.03 0.0004 < 0.03 [+] Expand Test Data
Year Test Date MRL HRL Test Result
2013 2013-11-11 0.03 0.0004 < 0.03
2013 2013-08-13 0.03 0.0004 < 0.03
2013 2013-05-13 0.03 0.0004 < 0.03
2013 2013-02-11 0.03 0.0004 < 0.03
1,3-butadiene 0.1 0.0103 < 0.1 [+] Expand Test Data
Year Test Date MRL HRL Test Result
2013 2013-11-11 0.1 0.0103 < 0.1
2013 2013-08-13 0.1 0.0103 < 0.1
2013 2013-05-13 0.1 0.0103 < 0.1
2013 2013-02-11 0.1 0.0103 < 0.1
1,4-dioxane 0.07 0.35 < 0.07 [+] Expand Test Data
Year Test Date MRL HRL Test Result
2013 2013-11-11 0.07 0.35 < 0.07
2013 2013-08-13 0.07 0.35 < 0.07
2013 2013-05-13 0.07 0.35 < 0.07
2013 2013-02-11 0.07 0.35 < 0.07
bromomethane 0.2 140 < 0.2 [+] Expand Test Data
Year Test Date MRL HRL Test Result
2013 2013-11-11 0.2 140 < 0.2
2013 2013-08-13 0.2 140 < 0.2
2013 2013-05-13 0.2 140 < 0.2
2013 2013-02-11 0.2 140 < 0.2
chloromethane 0.2 2.69 < 0.2 [+] Expand Test Data
Year Test Date MRL HRL Test Result
2013 2013-11-11 0.2 2.69 < 0.2
2013 2013-08-13 0.2 2.69 < 0.2
2013 2013-05-13 0.2 2.69 < 0.2
2013 2013-02-11 0.2 2.69 < 0.2
chromium 0.2 100 0.2075 [+] Expand Test Data
Year Test Date MRL HRL Test Result
2013 2013-11-11 0.2 100 0.33
2013 2013-11-11 0.2 100 0.35
2013 2013-08-13 0.2 100 0.26
2013 2013-08-13 0.2 100 0.24
2013 2013-06-18 0.2 100 0.24
2013 2013-06-18 0.2 100 0.24
2013 2013-02-11 0.2 100 < 0.2
2013 2013-02-11 0.2 100 < 0.2
chromium-6 0.03 0 0.08 [+] Expand Test Data
Year Test Date MRL HRL Test Result
2013 2013-11-11 0.03 0 0.041
2013 2013-11-11 0.03 0 0.064
2013 2013-08-13 0.03 0 0.077
2013 2013-08-13 0.03 0 0.061
2013 2013-05-13 0.03 0 0.14
2013 2013-05-13 0.03 0 0.16
2013 2013-02-11 0.03 0 0.034
2013 2013-02-11 0.03 0 0.063
cobalt 1 70 < 1 [+] Expand Test Data
Year Test Date MRL HRL Test Result
2013 2013-11-11 1 70 < 1
2013 2013-11-11 1 70 < 1
2013 2013-08-13 1 70 < 1
2013 2013-08-13 1 70 < 1
2013 2013-06-18 1 70 < 1
2013 2013-06-18 1 70 < 1
2013 2013-02-11 1 70 < 1
2013 2013-02-11 1 70 < 1
Halon 1011 0.06 90 < 0.06 [+] Expand Test Data
Year Test Date MRL HRL Test Result
2013 2013-11-11 0.06 90 < 0.06
2013 2013-08-13 0.06 90 < 0.06
2013 2013-05-13 0.06 90 < 0.06
2013 2013-02-11 0.06 90 < 0.06
HCFC-22 0.08 0 < 0.08 [+] Expand Test Data
Year Test Date MRL HRL Test Result
2013 2013-11-11 0.08 0 < 0.08
2013 2013-08-13 0.08 0 < 0.08
2013 2013-05-13 0.08 0 < 0.08
2013 2013-02-11 0.08 0 < 0.08
molybdenum 1 40 < 1 [+] Expand Test Data
Year Test Date MRL HRL Test Result
2013 2013-11-11 1 40 < 1
2013 2013-11-11 1 40 < 1
2013 2013-08-13 1 40 < 1
2013 2013-08-13 1 40 < 1
2013 2013-06-18 1 40 < 1
2013 2013-06-18 1 40 < 1
2013 2013-02-11 1 40 < 1
2013 2013-02-11 1 40 < 1
PFBS 0.09 0 < 0.09 [+] Expand Test Data
Year Test Date MRL HRL Test Result
2013 2013-11-11 0.09 0 < 0.09
2013 2013-08-13 0.09 0 < 0.09
2013 2013-05-13 0.09 0 < 0.09
2013 2013-02-11 0.09 0 < 0.09
PFHpA 0.01 0 < 0.01 [+] Expand Test Data
Year Test Date MRL HRL Test Result
2013 2013-11-11 0.01 0 < 0.01
2013 2013-08-13 0.01 0 < 0.01
2013 2013-05-13 0.01 0 < 0.01
2013 2013-02-11 0.01 0 < 0.01
PFHxS 0.03 0 < 0.03 [+] Expand Test Data
Year Test Date MRL HRL Test Result
2013 2013-11-11 0.03 0 < 0.03
2013 2013-08-13 0.03 0 < 0.03
2013 2013-05-13 0.03 0 < 0.03
2013 2013-02-11 0.03 0 < 0.03
PFNA 0.02 0 < 0.02 [+] Expand Test Data
Year Test Date MRL HRL Test Result
2013 2013-11-11 0.02 0 < 0.02
2013 2013-08-13 0.02 0 < 0.02
2013 2013-05-13 0.02 0 < 0.02
2013 2013-02-11 0.02 0 < 0.02
PFOA 0.02 0.07 < 0.02 [+] Expand Test Data
Year Test Date MRL HRL Test Result
2013 2013-11-11 0.02 0.07 < 0.02
2013 2013-08-13 0.02 0.07 < 0.02
2013 2013-05-13 0.02 0.07 < 0.02
2013 2013-02-11 0.02 0.07 < 0.02
PFOS 0.04 0.07 < 0.04 [+] Expand Test Data
Year Test Date MRL HRL Test Result
2013 2013-11-11 0.04 0.07 < 0.04
2013 2013-08-13 0.04 0.07 < 0.04
2013 2013-05-13 0.04 0.07 < 0.04
2013 2013-02-11 0.04 0.07 < 0.04
strontium 0.3 1500 84.1 [+] Expand Test Data
Year Test Date MRL HRL Test Result
2013 2013-11-11 0.3 1500 82.6
2013 2013-11-11 0.3 1500 82.4
2013 2013-08-13 0.3 1500 98.8
2013 2013-08-13 0.3 1500 103
2013 2013-06-18 0.3 1500 80.6
2013 2013-06-18 0.3 1500 92.9
2013 2013-02-11 0.3 1500 69.6
2013 2013-02-11 0.3 1500 62.9
vanadium 0.2 21 0.9788 [+] Expand Test Data
Year Test Date MRL HRL Test Result
2013 2013-11-11 0.2 21 0.83
2013 2013-11-11 0.2 21 0.82
2013 2013-08-13 0.2 21 1.2
2013 2013-08-13 0.2 21 1.2
2013 2013-06-18 0.2 21 1.3
2013 2013-06-18 0.2 21 1.4
2013 2013-02-11 0.2 21 0.54
2013 2013-02-11 0.2 21 0.54

Lead and Copper Data


Lead and copper are recorded separately from other contaminants because of the Lead and Copper Rule. As with all other results, these are the findings at the water supply level. Lead and copper can be — and often are — deposited in drinking water in between the water facility and your tap.

Sample ID Contaminant Sampling Start Date Sampling End Date Result
OH70319 lead 2019-01-01 2019-12-31 0mg/L
OH68169 lead 2018-01-01 2018-12-31 0.0017mg/L
OH65000 lead 2015-01-01 2017-12-31 0mg/L
OH60033 lead 2012-01-01 2014-12-31 0mg/L
OH54851 lead 2009-01-01 2011-12-31 0.00955mg/L
OH46008 lead 2008-01-01 2010-12-31 0mg/L

Violations


Known violations of the Safe Drinking Water Act as recorded by the EPA.

Compliance Dates Rule Violation Type Contaminant Name Status
2003-04-01 - 2003-06-30 Stage 1 Disinfectants and Disinfection Byproducts Rule Monitoring and Reporting (DBP) Total Haloacetic Acids (HAA5) Returned to Compliance
- N/A Total Coliform Rule Maximum Contaminant Level Violation, Acute (TCR) Coliform (TCR) Returned to Compliance
- N/A Total Coliform Rule Monitoring, Repeat Major (TCR) Coliform (TCR) Returned to Compliance

Local Water Testing


Find a lab in your area so you can get your tap or well water tested. This list contains both governmental and private labs, all of which are EPA-certified for drinking water testing.

Lab Location Zip Code
Adams Water Lab, Inc. Akron, OH 44310
Akron WTP Laboratory Akron, OH 44240
Eastern Laboratory Services, LTD. Medina, OH 44256

Water Bill Information


Convenient information about your water service.

Unable to identify any billing information about Tallmadge City Pws (OH7704703).

What My Water Data Means


Water data isn't always easy to interpret, but by following the links on this page you should be able to have most of your questions answered. By clicking the name of a water contaminant or secondary substance you can learn about that specific substance. Ultimately this page should give you some insight towards learning if your water is safe, what water filter you should buy (if any), and how well your local water compares against other sources.

Sources


The origin of MyTapWater.org's water data is explained on our Data Sources page.

Why Is My Water Data Not More Recent?


The recency of the data for your ZIP code depends on the last your water source was tested, by a federal, state, or local agency. More information about the timing can be determined by learning about the dataset in question and seeing how often the EPA (other another governing body) mandated testing.