Public Water System: Aqua Nj - Eastern Division

MyTapWater.org's tap water quality report is the compilation of data collected from federal, state, and local government agencies, most prominently the EPA. We strive to populate the report with the latest data concerning water contaminants, lead and copper levels, and water quality violations. We only collect drinking water data from public water systems.

PWS Service Information
PWS ID: NJ1505002
Type: Community water system
EPA Region: 02
Primary Service Area: Residential Area
Primary Source: Ground water
Population Served: 12,000
Contact Information
SUTO, RON
SUTO, RON
AQUA NJ CENTRAL DIVISION
10 BLACK FRST RD
HAMILTON, NJ 08691

This public water system services 3 zip codes in 1 municipality in 1 county.

Summary Results


A summary view of the the times a water contaminant was tested and found to exceed the level set by the EPA (the MCL).

Maximum Contaminant Levels Exceeded (by year):

2013   (1) 2014   (0) 2015   (0)
1,4-dioxane

Contaminant Detailed Results


This a view of violations of maximum contaminant levels. In the expanded view you can see each know test date for a given contaminant, the result of the test, the minimum level that can be recognized in a test (MRL), and upper limit that is considered healthy (HRL).

1,4-dioxane
Is this in your home's pipes?

Year Test Date MRL HRL Test Result
2013 2013-10-15 0.07 0.35 < 0.07
2013 2013-10-15 0.07 0.35 5.4
2013 2013-04-23 0.07 0.35 < 0.07
2013 2013-03-26 0.07 0.35 3.89

Other Water Contaminants Tested


The following contaminants were tested and within national EPA guidelines.

The last mile of pipe makes a big difference, learn more about testing your water.

Contaminant MRL HRL Avg Result
1,2,3-trichloropropane 0.03 0.0004 < 0.03 [+] Expand Test Data
Year Test Date MRL HRL Test Result
2013 2013-09-17 0.03 0.0004 < 0.03
2013 2013-09-17 0.03 0.0004 < 0.03
2013 2013-03-29 0.03 0.0004 < 0.03
2013 2013-03-21 0.03 0.0004 < 0.03
Halon 1011 0.06 90 < 0.06 [+] Expand Test Data
Year Test Date MRL HRL Test Result
2013 2013-09-17 0.06 90 < 0.06
2013 2013-09-17 0.06 90 < 0.06
2013 2013-03-29 0.06 90 < 0.06
2013 2013-03-21 0.06 90 < 0.06
1,3-butadiene 0.1 0.0103 < 0.1 [+] Expand Test Data
Year Test Date MRL HRL Test Result
2013 2013-09-17 0.1 0.0103 < 0.1
2013 2013-09-17 0.1 0.0103 < 0.1
2013 2013-03-29 0.1 0.0103 < 0.1
2013 2013-03-21 0.1 0.0103 < 0.1
bromomethane 0.2 140 < 0.2 [+] Expand Test Data
Year Test Date MRL HRL Test Result
2013 2013-09-17 0.2 140 < 0.2
2013 2013-09-17 0.2 140 < 0.2
2013 2013-03-29 0.2 140 < 0.2
2013 2013-03-21 0.2 140 < 0.2
chlorate 20 210 62.1667 [+] Expand Test Data
Year Test Date MRL HRL Test Result
2013 2013-09-24 20 210 53
2013 2013-09-17 20 210 120
2013 2013-09-17 20 210 67
2013 2013-03-29 20 210 66
2013 2013-03-21 20 210 23
2013 2013-03-19 20 210 44
1,1-dichloroethane 0.03 6.14 0.0198 [+] Expand Test Data
Year Test Date MRL HRL Test Result
2013 2013-09-17 0.03 6.14 0.079
2013 2013-09-17 0.03 6.14 < 0.03
2013 2013-03-29 0.03 6.14 < 0.03
2013 2013-03-21 0.03 6.14 < 0.03
chloromethane 0.2 2.69 < 0.2 [+] Expand Test Data
Year Test Date MRL HRL Test Result
2013 2013-09-17 0.2 2.69 < 0.2
2013 2013-09-17 0.2 2.69 < 0.2
2013 2013-03-29 0.2 2.69 < 0.2
2013 2013-03-21 0.2 2.69 < 0.2
chromium 0.2 100 0.0683 [+] Expand Test Data
Year Test Date MRL HRL Test Result
2013 2013-09-17 0.2 100 < 0.2
2013 2013-09-17 0.2 100 0.41
2013 2013-09-17 0.2 100 < 0.2
2013 2013-03-29 0.2 100 < 0.2
2013 2013-03-21 0.2 100 < 0.2
2013 2013-03-19 0.2 100 < 0.2
PFOS 0.04 0.07 < 0.04 [+] Expand Test Data
Year Test Date MRL HRL Test Result
2013 2013-10-15 0.04 0.07 < 0.04
2013 2013-10-15 0.04 0.07 < 0.04
2013 2013-03-26 0.04 0.07 < 0.04
2013 2013-03-19 0.04 0.07 < 0.04
chromium-6 0.03 0 0.085 [+] Expand Test Data
Year Test Date MRL HRL Test Result
2013 2013-09-17 0.03 0 < 0.03
2013 2013-09-17 0.03 0 0.28
2013 2013-09-17 0.03 0 < 0.03
2013 2013-03-29 0.03 0 0.04
2013 2013-03-21 0.03 0 < 0.03
2013 2013-03-19 0.03 0 0.19
vanadium 0.2 21 0.2017 [+] Expand Test Data
Year Test Date MRL HRL Test Result
2013 2013-10-22 0.2 21 < 0.2
2013 2013-09-17 0.2 21 0.42
2013 2013-09-17 0.2 21 < 0.2
2013 2013-03-29 0.2 21 0.28
2013 2013-03-21 0.2 21 0.21
2013 2013-03-19 0.2 21 0.3
cobalt 1 70 0.9667 [+] Expand Test Data
Year Test Date MRL HRL Test Result
2013 2013-10-22 1 70 2.5
2013 2013-09-17 1 70 < 1
2013 2013-09-17 1 70 1
2013 2013-03-29 1 70 2.3
2013 2013-03-21 1 70 < 1
2013 2013-03-19 1 70 < 1
strontium 0.3 1500 24.5 [+] Expand Test Data
Year Test Date MRL HRL Test Result
2013 2013-10-22 0.3 1500 14
2013 2013-09-17 0.3 1500 45
2013 2013-09-17 0.3 1500 20
2013 2013-03-29 0.3 1500 13
2013 2013-03-21 0.3 1500 21
2013 2013-03-19 0.3 1500 34
PFOA 0.02 0.07 < 0.02 [+] Expand Test Data
Year Test Date MRL HRL Test Result
2013 2013-10-15 0.02 0.07 < 0.02
2013 2013-10-15 0.02 0.07 < 0.02
2013 2013-03-26 0.02 0.07 < 0.02
2013 2013-03-19 0.02 0.07 < 0.02
PFHxS 0.03 0 < 0.03 [+] Expand Test Data
Year Test Date MRL HRL Test Result
2013 2013-10-15 0.03 0 < 0.03
2013 2013-10-15 0.03 0 < 0.03
2013 2013-03-26 0.03 0 < 0.03
2013 2013-03-19 0.03 0 < 0.03
molybdenum 1 40 < 1 [+] Expand Test Data
Year Test Date MRL HRL Test Result
2013 2013-09-17 1 40 < 1
2013 2013-09-17 1 40 < 1
2013 2013-09-17 1 40 < 1
2013 2013-03-29 1 40 < 1
2013 2013-03-21 1 40 < 1
2013 2013-03-19 1 40 < 1
PFHpA 0.01 0 < 0.01 [+] Expand Test Data
Year Test Date MRL HRL Test Result
2013 2013-10-15 0.01 0 < 0.01
2013 2013-10-15 0.01 0 < 0.01
2013 2013-03-26 0.01 0 < 0.01
2013 2013-03-19 0.01 0 < 0.01
HCFC-22 0.08 0 < 0.08 [+] Expand Test Data
Year Test Date MRL HRL Test Result
2013 2013-09-17 0.08 0 < 0.08
2013 2013-09-17 0.08 0 < 0.08
2013 2013-03-29 0.08 0 < 0.08
2013 2013-03-21 0.08 0 < 0.08
PFBS 0.09 0 < 0.09 [+] Expand Test Data
Year Test Date MRL HRL Test Result
2013 2013-10-15 0.09 0 < 0.09
2013 2013-10-15 0.09 0 < 0.09
2013 2013-03-26 0.09 0 < 0.09
2013 2013-03-19 0.09 0 < 0.09
PFNA 0.02 0 < 0.02 [+] Expand Test Data
Year Test Date MRL HRL Test Result
2013 2013-10-15 0.02 0 < 0.02
2013 2013-10-15 0.02 0 < 0.02
2013 2013-03-26 0.02 0 < 0.02
2013 2013-03-19 0.02 0 < 0.02

Lead and Copper Data


Lead and copper are recorded separately from other contaminants because of the Lead and Copper Rule. As with all other results, these are the findings at the water supply. Lead and copper can be — and often are — added to drinking water in between the water facility and a tap.

Sample ID Contaminant Sampling Start Date Sampling End Date Result
NJ141568 lead 2015-01-01 2017-12-31 0mg/L
NJ137316 lead 2012-01-01 2014-12-31 0mg/L
NJ137738 lead 2012-01-01 2014-12-31 0mg/L
NJ133278 lead 2009-01-01 2011-12-31 0mg/L
NJ123829 lead 2006-01-01 2008-12-31 0.0003mg/L

Violations


Known violations of the Safe Drinking Water Act as recorded by the EPA.

Compliance Dates Rule Violation Type Contaminant Name Status
2016-07-01 - 2016-09-30 Stage 2 Disinfectants and Disinfection Byproducts Rule Monitoring and Reporting (DBP) Total Haloacetic Acids (HAA5) Returned to Compliance
2014-04-01 - 2014-06-30 Volatile Organic Chemicals Monitoring, Regular 1,2,4-Trichlorobenzene Returned to Compliance
2014-04-01 - 2014-06-30 Volatile Organic Chemicals Monitoring, Regular cis-1,2-Dichloroethylene Returned to Compliance
2014-04-01 - 2014-06-30 Volatile Organic Chemicals Monitoring, Regular Xylenes, Total Returned to Compliance
2014-04-01 - 2014-06-30 Volatile Organic Chemicals Monitoring, Regular DICHLOROMETHANE Returned to Compliance
2014-04-01 - 2014-06-30 Volatile Organic Chemicals Monitoring, Regular o-Dichlorobenzene Returned to Compliance
2014-04-01 - 2014-06-30 Volatile Organic Chemicals Monitoring, Regular p-Dichlorobenzene Returned to Compliance
2014-04-01 - 2014-06-30 Volatile Organic Chemicals Monitoring, Regular Vinyl chloride Returned to Compliance
2014-04-01 - 2014-06-30 Volatile Organic Chemicals Monitoring, Regular 1,1-Dichloroethylene Returned to Compliance
2014-04-01 - 2014-06-30 Volatile Organic Chemicals Monitoring, Regular trans-1,2-Dichloroethylene Returned to Compliance
2014-04-01 - 2014-06-30 Volatile Organic Chemicals Monitoring, Regular 1,2-Dichloroethane Returned to Compliance
2014-04-01 - 2014-06-30 Volatile Organic Chemicals Monitoring, Regular 1,1,1-Trichloroethane Returned to Compliance
2014-04-01 - 2014-06-30 Volatile Organic Chemicals Monitoring, Regular Carbon tetrachloride Returned to Compliance
2014-04-01 - 2014-06-30 Volatile Organic Chemicals Monitoring, Regular 1,2-Dichloropropane Returned to Compliance
2014-04-01 - 2014-06-30 Volatile Organic Chemicals Monitoring, Regular Trichloroethylene Returned to Compliance
2014-04-01 - 2014-06-30 Volatile Organic Chemicals Monitoring, Regular 1,1,2-Trichloroethane Returned to Compliance
2014-04-01 - 2014-06-30 Volatile Organic Chemicals Monitoring, Regular Tetrachloroethylene Returned to Compliance
2014-04-01 - 2014-06-30 Volatile Organic Chemicals Monitoring, Regular CHLOROBENZENE Returned to Compliance
2014-04-01 - 2014-06-30 Volatile Organic Chemicals Monitoring, Regular Benzene Returned to Compliance
2014-04-01 - 2014-06-30 Volatile Organic Chemicals Monitoring, Regular Toluene Returned to Compliance
2014-04-01 - 2014-06-30 Volatile Organic Chemicals Monitoring, Regular Ethylbenzene Returned to Compliance
2014-04-01 - 2014-06-30 Volatile Organic Chemicals Monitoring, Regular Styrene Returned to Compliance
1980-07-01 - 1984-06-30 Radionuclides Monitoring, Regular Gross Alpha, Excl. Radon and U Known
1979-06-24 - 1982-06-23 Inorganic Chemicals Monitoring, Regular Selenium Known
1979-06-24 - 1982-06-23 Inorganic Chemicals Monitoring, Regular Mercury Known
1979-06-24 - 1982-06-23 Arsenic Monitoring, Regular Arsenic Known
1979-06-24 - 1982-06-23 Inorganic Chemicals Monitoring, Regular Barium Known
1979-06-24 - 1982-06-23 Inorganic Chemicals Monitoring, Regular Cadmium Known
1979-06-24 - 1982-06-23 Inorganic Chemicals Monitoring, Regular Fluoride Known
1979-06-24 - 1982-06-23 Inorganic Chemicals Monitoring, Regular Chromium Known

What My Water Data Means


Water data isn't always easy to interpret, but by following the links on this page you should be able to have most of your questions answered. By clicking the name of a water contaminant or secondary substance you can learn about that specific substance. Ultimately this page should give you some insight towards learning if your water is safe, what water filter you should buy (if any), and how well your local water compares against other sources.

Sources


The origin of MyTapWater.org's water data is explained on our Data Sources page.

Why Is My Water Data Not More Recent?


The recency of the data for your ZIP code depends on the last your water source was tested, by a federal, state, or local agency. More information about the timing can be determined by learning about the dataset in question and seeing how often the EPA (other another governing body) mandated testing.