Public Water System: Joint Powers Water Board

MyTapWater.org's tap water quality report is the compilation of data collected from federal, state, and local government agencies, most prominently the EPA. We strive to populate the report with the latest data concerning water contaminants, lead and copper levels, and water quality violations. We only collect drinking water data from public water systems.

PWS Service Information
PWS ID: MN1860024
Type: Community water system
EPA Region: 05
Primary Service Area: Municipality
Primary Source: Ground water
Population Served: 22,072
Contact Information
Joint Powers Water Board
11100 50th Street NE
Albertville, MN 55301

This public water system services 3 zip codes in 1 municipality in 1 county.

Summary Results


A summary view of the the times a water contaminant was tested and found to exceed the level set by the EPA (the MCL).

Maximum Contaminant Levels Exceeded (by year):

2013   (0) 2014   (1) 2015   (0)
chlorate

Contaminant Detailed Results


This a view of violations of maximum contaminant levels. In the expanded view you can see each know test date for a given contaminant, the result of the test, the minimum level that can be recognized in a test (MRL), and upper limit that is considered healthy (HRL).

chlorate
Is this in your home's pipes?

Year Test Date MRL HRL Test Result
2014 2014-07-07 20 210 262
2014 2014-07-07 20 210 177
2014 2014-01-23 20 210 120
2014 2014-01-23 20 210 120

Other Water Contaminants Tested


The following contaminants were tested and within national EPA guidelines.

The last mile of pipe makes a big difference, learn more about testing your water.

Contaminant MRL HRL Avg Result
estriol 0.0008 0.35 < 0.0008 [+] Expand Test Data
Year Test Date MRL HRL Test Result
2014 2014-07-07 0.0008 0.35 < 0.0008
2014 2014-01-23 0.0008 0.35 < 0.0008
4-androstene-3,17-dione 0.0003 0 < 0.0003 [+] Expand Test Data
Year Test Date MRL HRL Test Result
2014 2014-07-07 0.0003 0 < 0.0003
2014 2014-01-23 0.0003 0 < 0.0003
testosterone 0.0001 0 < 0.0001 [+] Expand Test Data
Year Test Date MRL HRL Test Result
2014 2014-07-07 0.0001 0 < 0.0001
2014 2014-01-23 0.0001 0 < 0.0001
estrone 0.002 0.35 < 0.002 [+] Expand Test Data
Year Test Date MRL HRL Test Result
2014 2014-07-07 0.002 0.35 < 0.002
2014 2014-01-23 0.002 0.35 < 0.002
equilin 0.004 0.35 < 0.004 [+] Expand Test Data
Year Test Date MRL HRL Test Result
2014 2014-07-07 0.004 0.35 < 0.004
2014 2014-01-23 0.004 0.35 < 0.004
PFOA 0.02 0.07 < 0.02 [+] Expand Test Data
Year Test Date MRL HRL Test Result
2014 2014-07-07 0.02 0.07 < 0.02
2014 2014-01-23 0.02 0.07 < 0.02
chromium-6 0.03 0 0.0075 [+] Expand Test Data
Year Test Date MRL HRL Test Result
2014 2014-07-07 0.03 0 < 0.03
2014 2014-07-07 0.03 0 < 0.03
2014 2014-01-23 0.03 0 0.03
2014 2014-01-23 0.03 0 < 0.03
1,4-dioxane 0.07 0.35 < 0.07 [+] Expand Test Data
Year Test Date MRL HRL Test Result
2014 2014-07-07 0.07 0.35 < 0.07
2014 2014-03-06 0.07 0.35 < 0.07
17-beta-estradiol 0.0004 0.0009 < 0.0004 [+] Expand Test Data
Year Test Date MRL HRL Test Result
2014 2014-07-07 0.0004 0.0009 < 0.0004
2014 2014-01-23 0.0004 0.0009 < 0.0004
17-alpha-ethynylestradiol 0.0009 0.035 < 0.0009 [+] Expand Test Data
Year Test Date MRL HRL Test Result
2014 2014-07-07 0.0009 0.035 < 0.0009
2014 2014-01-23 0.0009 0.035 < 0.0009
1,3-butadiene 0.1 0.0103 < 0.1 [+] Expand Test Data
Year Test Date MRL HRL Test Result
2014 2014-07-07 0.1 0.0103 < 0.1
2014 2014-01-23 0.1 0.0103 < 0.1
molybdenum 1 40 2.25 [+] Expand Test Data
Year Test Date MRL HRL Test Result
2014 2014-07-07 1 40 2.3
2014 2014-07-07 1 40 2.2
2014 2014-01-23 1 40 2.3
2014 2014-01-23 1 40 2.2
strontium 0.3 1500 307 [+] Expand Test Data
Year Test Date MRL HRL Test Result
2014 2014-07-07 0.3 1500 321
2014 2014-07-07 0.3 1500 299
2014 2014-01-23 0.3 1500 305
2014 2014-01-23 0.3 1500 303
cobalt 1 70 < 1 [+] Expand Test Data
Year Test Date MRL HRL Test Result
2014 2014-07-07 1 70 < 1
2014 2014-07-07 1 70 < 1
2014 2014-01-23 1 70 < 1
2014 2014-01-23 1 70 < 1
PFOS 0.04 0.07 < 0.04 [+] Expand Test Data
Year Test Date MRL HRL Test Result
2014 2014-07-07 0.04 0.07 < 0.04
2014 2014-01-23 0.04 0.07 < 0.04
chromium 0.2 100 0.1175 [+] Expand Test Data
Year Test Date MRL HRL Test Result
2014 2014-07-07 0.2 100 0.22
2014 2014-07-07 0.2 100 0.25
2014 2014-01-23 0.2 100 < 0.2
2014 2014-01-23 0.2 100 < 0.2
vanadium 0.2 21 < 0.2 [+] Expand Test Data
Year Test Date MRL HRL Test Result
2014 2014-07-07 0.2 21 < 0.2
2014 2014-07-07 0.2 21 < 0.2
2014 2014-01-23 0.2 21 < 0.2
2014 2014-01-23 0.2 21 < 0.2
PFBS 0.09 0 < 0.09 [+] Expand Test Data
Year Test Date MRL HRL Test Result
2014 2014-07-07 0.09 0 < 0.09
2014 2014-01-23 0.09 0 < 0.09
PFHpA 0.01 0 < 0.01 [+] Expand Test Data
Year Test Date MRL HRL Test Result
2014 2014-07-07 0.01 0 < 0.01
2014 2014-01-23 0.01 0 < 0.01
PFNA 0.02 0 < 0.02 [+] Expand Test Data
Year Test Date MRL HRL Test Result
2014 2014-07-07 0.02 0 < 0.02
2014 2014-01-23 0.02 0 < 0.02
bromomethane 0.2 140 < 0.2 [+] Expand Test Data
Year Test Date MRL HRL Test Result
2014 2014-07-07 0.2 140 < 0.2
2014 2014-01-23 0.2 140 < 0.2
1,2,3-trichloropropane 0.03 0.0004 < 0.03 [+] Expand Test Data
Year Test Date MRL HRL Test Result
2014 2014-07-07 0.03 0.0004 < 0.03
2014 2014-01-23 0.03 0.0004 < 0.03
HCFC-22 0.08 0 < 0.08 [+] Expand Test Data
Year Test Date MRL HRL Test Result
2014 2014-07-07 0.08 0 < 0.08
2014 2014-01-23 0.08 0 < 0.08
chloromethane 0.2 2.69 < 0.2 [+] Expand Test Data
Year Test Date MRL HRL Test Result
2014 2014-07-07 0.2 2.69 < 0.2
2014 2014-01-23 0.2 2.69 < 0.2
1,1-dichloroethane 0.03 6.14 < 0.03 [+] Expand Test Data
Year Test Date MRL HRL Test Result
2014 2014-07-07 0.03 6.14 < 0.03
2014 2014-01-23 0.03 6.14 < 0.03
Halon 1011 0.06 90 < 0.06 [+] Expand Test Data
Year Test Date MRL HRL Test Result
2014 2014-07-07 0.06 90 < 0.06
2014 2014-01-23 0.06 90 < 0.06
PFHxS 0.03 0 < 0.03 [+] Expand Test Data
Year Test Date MRL HRL Test Result
2014 2014-07-07 0.03 0 < 0.03
2014 2014-01-23 0.03 0 < 0.03

Lead and Copper Data


Lead and copper are recorded separately from other contaminants because of the Lead and Copper Rule. As with all other results, these are the findings at the water supply. Lead and copper can be — and often are — added to drinking water in between the water facility and a tap.

Sample ID Contaminant Sampling Start Date Sampling End Date Result
1134597 lead 2014-01-01 2016-12-31 0.001mg/L
1074190 lead 2013-01-01 2013-12-31 0.001mg/L
956255 lead 2012-01-01 2012-12-31 0.001mg/L
956256 lead 2011-01-01 2011-12-31 0.001mg/L
720381 copper 2008-01-01 2010-12-31 1.37mg/L

Violations


Known violations of the Safe Drinking Water Act as recorded by the EPA.

No violations found for Joint Powers Water Board.


What My Water Data Means


Water data isn't always easy to interpret, but by following the links on this page you should be able to have most of your questions answered. By clicking the name of a water contaminant or secondary substance you can learn about that specific substance. Ultimately this page should give you some insight towards learning if your water is safe, what water filter you should buy (if any), and how well your local water compares against other sources.

Sources


The origin of MyTapWater.org's water data is explained on our Data Sources page.

Why Is My Water Data Not More Recent?


The recency of the data for your ZIP code depends on the last your water source was tested, by a federal, state, or local agency. More information about the timing can be determined by learning about the dataset in question and seeing how often the EPA (other another governing body) mandated testing.