Westland Water System

MyTapWater.org's tap water quality report is the compilation of data collected from federal, state, and local government agencies, most prominently the EPA. We strive to populate the report with the latest data concerning water contaminants, lead and copper levels, and water quality violations. We only collect drinking water data from public water systems.

PWS Service Information
PWS ID: MI0007040
Type: Community water system
EPA Region: 05
Primary Service Area: Residential Area
Primary Source: Surface water purchased
Population Served: 84,094
Contact Information
MCCUSKER, BENNY
MCCUSKER, BENNY
37173 MARQUETTE
WESTLAND, MI 48185
[email protected]

This public water system services 1 municipality in 1 county.

Summary Results


A summary view of tests in which a water contaminant found to exceed the Maximum Contaminant Level (MCL) set by the EPA.

Maximum Contaminant Levels Exceeded (by year):

2013   (0) 2014   (0) 2015   (0) 2016   (0) 2017   (0) 2018   (3)
anatoxin-a
cylindrospermopsin
total microcystin

Contaminant Detailed Results


This a view of violations of maximum contaminant levels. Use the expanded view see result data for a drinking water contaminant, the minimum level that can be recognized in a test (MRL), and upper limit that is considered healthy (HRL).

anatoxin-a

Year Test Date MRLMinimum Reporting Level HRLHealth Risk Limit Test Result
2018 2018-04-20 0.03 0.00 < 0.03
2018 2018-04-04 0.03 0.00 < 0.03

cylindrospermopsin

Year Test Date MRLMinimum Reporting Level HRLHealth Risk Limit Test Result
2018 2018-04-20 0.09 0.00 < 0.09
2018 2018-04-04 0.09 0.00 < 0.09

total microcystin

Year Test Date MRLMinimum Reporting Level HRLHealth Risk Limit Test Result
2018 2018-04-20 0.3 0.00 < 0.3
2018 2018-04-04 0.3 0.00 < 0.3

Other Water Contaminants Tested


The following contaminants were tested and found to be within national EPA guidelines.

Contaminant MRLMinimum Reporting Level HRLHealth Risk Limit Avg Result
chlorate 20 210 < 20 [+] Expand Test Data
Year Test Date MRL HRL Test Result
2015 2015-10-21 20 210 < 20
2015 2015-10-21 20 210 < 20
2015 2015-07-28 20 210 < 20
2015 2015-07-28 20 210 < 20
2015 2015-04-21 20 210 < 20
2015 2015-04-21 20 210 < 20
2015 2015-01-20 20 210 < 20
2015 2015-01-20 20 210 < 20
chromium 0.2 100 0.1561 [+] Expand Test Data
Year Test Date MRL HRL Test Result
2015 2015-10-21 0.2 100 0.304
2015 2015-10-21 0.2 100 0.358
2015 2015-07-28 0.2 100 0.258
2015 2015-07-28 0.2 100 0.329
2015 2015-04-21 0.2 100 < 0.2
2015 2015-04-21 0.2 100 < 0.2
2015 2015-01-20 0.2 100 < 0.2
2015 2015-01-20 0.2 100 < 0.2
chromium-6 0.03 0 0.1661 [+] Expand Test Data
Year Test Date MRL HRL Test Result
2015 2015-10-21 0.03 0 0.235
2015 2015-10-21 0.03 0 0.245
2015 2015-07-28 0.03 0 0.21
2015 2015-07-28 0.03 0 0.241
2015 2015-04-21 0.03 0 0.115
2015 2015-04-21 0.03 0 0.107
2015 2015-01-20 0.03 0 0.1
2015 2015-01-20 0.03 0 0.076
cobalt 1 70 < 1 [+] Expand Test Data
Year Test Date MRL HRL Test Result
2015 2015-10-21 1 70 < 1
2015 2015-10-21 1 70 < 1
2015 2015-07-28 1 70 < 1
2015 2015-07-28 1 70 < 1
2015 2015-04-21 1 70 < 1
2015 2015-04-21 1 70 < 1
2015 2015-01-20 1 70 < 1
2015 2015-01-20 1 70 < 1
molybdenum 1 40 < 1 [+] Expand Test Data
Year Test Date MRL HRL Test Result
2015 2015-10-21 1 40 < 1
2015 2015-10-21 1 40 < 1
2015 2015-07-28 1 40 < 1
2015 2015-07-28 1 40 < 1
2015 2015-04-21 1 40 < 1
2015 2015-04-21 1 40 < 1
2015 2015-01-20 1 40 < 1
2015 2015-01-20 1 40 < 1
strontium 0.3 1500 102.544 [+] Expand Test Data
Year Test Date MRL HRL Test Result
2015 2015-10-21 0.3 1500 99.729
2015 2015-10-21 0.3 1500 103.314
2015 2015-07-28 0.3 1500 103.781
2015 2015-07-28 0.3 1500 106.141
2015 2015-04-21 0.3 1500 103.518
2015 2015-04-21 0.3 1500 96.467
2015 2015-01-20 0.3 1500 105.298
2015 2015-01-20 0.3 1500 102.104
vanadium 0.2 21 0.3363 [+] Expand Test Data
Year Test Date MRL HRL Test Result
2015 2015-10-21 0.2 21 0.617
2015 2015-10-21 0.2 21 0.599
2015 2015-07-28 0.2 21 0.612
2015 2015-07-28 0.2 21 0.63
2015 2015-04-21 0.2 21 0.232
2015 2015-04-21 0.2 21 < 0.2
2015 2015-01-20 0.2 21 < 0.2
2015 2015-01-20 0.2 21 < 0.2
1,1-dichloroethane 0.03 6.14 < 0.03 [+] Expand Test Data
Year Test Date MRL HRL Test Result
2015 2015-10-21 0.03 6.14 < 0.03
2015 2015-07-28 0.03 6.14 < 0.03
2015 2015-04-21 0.03 6.14 < 0.03
2015 2015-01-20 0.03 6.14 < 0.03
1,2,3-trichloropropane 0.03 0.0004 < 0.03 [+] Expand Test Data
Year Test Date MRL HRL Test Result
2015 2015-10-21 0.03 0.0004 < 0.03
2015 2015-07-28 0.03 0.0004 < 0.03
2015 2015-04-21 0.03 0.0004 < 0.03
2015 2015-01-20 0.03 0.0004 < 0.03
1,3-butadiene 0.1 0.0103 < 0.1 [+] Expand Test Data
Year Test Date MRL HRL Test Result
2015 2015-10-21 0.1 0.0103 < 0.1
2015 2015-07-28 0.1 0.0103 < 0.1
2015 2015-04-21 0.1 0.0103 < 0.1
2015 2015-01-20 0.1 0.0103 < 0.1
1,4-dioxane 0.07 0.35 < 0.07 [+] Expand Test Data
Year Test Date MRL HRL Test Result
2015 2015-10-21 0.07 0.35 < 0.07
2015 2015-07-28 0.07 0.35 < 0.07
2015 2015-04-21 0.07 0.35 < 0.07
2015 2015-01-20 0.07 0.35 < 0.07
bromomethane 0.2 140 < 0.2 [+] Expand Test Data
Year Test Date MRL HRL Test Result
2015 2015-10-21 0.2 140 < 0.2
2015 2015-07-28 0.2 140 < 0.2
2015 2015-04-21 0.2 140 < 0.2
2015 2015-01-20 0.2 140 < 0.2
chloromethane 0.2 2.69 < 0.2 [+] Expand Test Data
Year Test Date MRL HRL Test Result
2015 2015-10-21 0.2 2.69 < 0.2
2015 2015-07-28 0.2 2.69 < 0.2
2015 2015-04-21 0.2 2.69 < 0.2
2015 2015-01-20 0.2 2.69 < 0.2
Halon 1011 0.06 90 < 0.06 [+] Expand Test Data
Year Test Date MRL HRL Test Result
2015 2015-10-21 0.06 90 < 0.06
2015 2015-07-28 0.06 90 < 0.06
2015 2015-04-21 0.06 90 < 0.06
2015 2015-01-20 0.06 90 < 0.06
HCFC-22 0.08 0 < 0.08 [+] Expand Test Data
Year Test Date MRL HRL Test Result
2015 2015-10-21 0.08 0 < 0.08
2015 2015-07-28 0.08 0 < 0.08
2015 2015-04-21 0.08 0 < 0.08
2015 2015-01-20 0.08 0 < 0.08
PFBS 0.09 0 < 0.09 [+] Expand Test Data
Year Test Date MRL HRL Test Result
2015 2015-10-21 0.09 0 < 0.09
2015 2015-07-28 0.09 0 < 0.09
2015 2015-04-21 0.09 0 < 0.09
2015 2015-01-20 0.09 0 < 0.09
PFHpA 0.01 0 < 0.01 [+] Expand Test Data
Year Test Date MRL HRL Test Result
2015 2015-10-21 0.01 0 < 0.01
2015 2015-07-28 0.01 0 < 0.01
2015 2015-04-21 0.01 0 < 0.01
2015 2015-01-20 0.01 0 < 0.01
PFHxS 0.03 0 < 0.03 [+] Expand Test Data
Year Test Date MRL HRL Test Result
2015 2015-10-21 0.03 0 < 0.03
2015 2015-07-28 0.03 0 < 0.03
2015 2015-04-21 0.03 0 < 0.03
2015 2015-01-20 0.03 0 < 0.03
PFNA 0.02 0 < 0.02 [+] Expand Test Data
Year Test Date MRL HRL Test Result
2015 2015-10-21 0.02 0 < 0.02
2015 2015-07-28 0.02 0 < 0.02
2015 2015-04-21 0.02 0 < 0.02
2015 2015-01-20 0.02 0 < 0.02
PFOA 0.02 0.07 < 0.02 [+] Expand Test Data
Year Test Date MRL HRL Test Result
2015 2015-10-21 0.02 0.07 < 0.02
2015 2015-07-28 0.02 0.07 < 0.02
2015 2015-04-21 0.02 0.07 < 0.02
2015 2015-01-20 0.02 0.07 < 0.02
PFOS 0.04 0.07 < 0.04 [+] Expand Test Data
Year Test Date MRL HRL Test Result
2015 2015-10-21 0.04 0.07 < 0.04
2015 2015-07-28 0.04 0.07 < 0.04
2015 2015-04-21 0.04 0.07 < 0.04
2015 2015-01-20 0.04 0.07 < 0.04

Lead and Copper Data


Lead and copper are recorded separately from other contaminants because of the Lead and Copper Rule. As with all other results, these are the findings at the water supply level. Lead and copper can be — and often are — deposited in drinking water in between the water facility and your tap.

Sample ID Contaminant Sampling Start Date Sampling End Date Result
MI226416 lead 2015-01-01 2017-12-31 0.00231mg/L
MI174632 lead 2012-01-01 2014-12-31 0.0028mg/L
MI118760 lead 2009-01-01 2011-12-31 0.0012mg/L
MI68079 lead 2006-01-01 2008-12-31 0.003mg/L

Violations


Known violations of the Safe Drinking Water Act as recorded by the EPA.

Compliance Dates Rule Violation Type Contaminant Name Status
2010-08-01 - 2010-08-31 Total Coliform Rule Monitoring, Routine Minor (TCR) Coliform (TCR) Returned to Compliance
2001-07-01 - N/A Consumer Confidence Rule Consumer Confidence Report Complete Failure to Report Consumer Confidence Rule Returned to Compliance

Local Water Testing


Find a lab in your area so you can get your tap or well water tested. This list contains both governmental and private labs, all of which are EPA-certified for drinking water testing.

Lab Location Zip Code
National Testing Laboratories, Ltd. Ypsilanti, MI 48197
NSF International – MI Ann Arbor, MI 48105
National Testing Laboratories, Ltd. Ypsilanti, MI 48197

Water Bill Information


Convenient information about your water service.

Unable to identify any billing information about Westland (MI0007040).

What My Water Data Means


Water data isn't always easy to interpret, but by following the links on this page you should be able to have most of your questions answered. By clicking the name of a water contaminant or secondary substance you can learn about that specific substance. Ultimately this page should give you some insight towards learning if your water is safe, what water filter you should buy (if any), and how well your local water compares against other sources.

Sources


The origin of MyTapWater.org's water data is explained on our Data Sources page.

Why Is My Water Data Not More Recent?


The recency of the data for your ZIP code depends on the last your water source was tested, by a federal, state, or local agency. More information about the timing can be determined by learning about the dataset in question and seeing how often the EPA (other another governing body) mandated testing.