Public Water System: City Of Salisbury

MyTapWater.org's tap water quality report is the compilation of data collected from federal, state, and local government agencies, most prominently the EPA. We strive to populate the report with the latest data concerning water contaminants, lead and copper levels, and water quality violations. We only collect drinking water data from public water systems.

PWS Service Information
PWS ID: MD0220004
Type: Community water system
EPA Region: 03
Primary Service Area: Residential Area
Primary Source: Ground water
Population Served: 30,343
Contact Information
CAMERON, CORRINE
CAMERON, CORRINE
2322 SCENIC DRIVE
SALISBURY, MD 21801

This public water system services 1 zip code in 1 municipality in 1 county.

Summary Results


A summary view of the the times a water contaminant was tested and found to exceed the level set by the EPA (the MCL).

Maximum Contaminant Levels Exceeded (by year):

2013   (1) 2014   (1) 2015   (0)
1,2,3-trichloropropane 1,2,3-trichloropropane

Contaminant Detailed Results


This a view of violations of maximum contaminant levels. In the expanded view you can see each know test date for a given contaminant, the result of the test, the minimum level that can be recognized in a test (MRL), and upper limit that is considered healthy (HRL).

1,2,3-trichloropropane
Is this in your home's pipes?

Year Test Date MRL HRL Test Result
2014 2014-01-15 0.03 0.0004 < 0.03
2014 2014-01-15 0.03 0.0004 0.073
2013 2013-07-09 0.03 0.0004 0.073
2013 2013-07-09 0.03 0.0004 < 0.03

Other Water Contaminants Tested


The following contaminants were tested and within national EPA guidelines.

The last mile of pipe makes a big difference, learn more about testing your water.

Contaminant MRL HRL Avg Result
chlorate 20 210 < 20 [+] Expand Test Data
Year Test Date MRL HRL Test Result
2014 2014-01-15 20 210 < 20
2014 2014-01-15 20 210 < 20
2014 2014-01-15 20 210 < 20
2014 2014-01-15 20 210 < 20
2013 2013-07-09 20 210 < 20
2013 2013-07-09 20 210 < 20
2013 2013-07-09 20 210 < 20
2013 2013-07-09 20 210 < 20
bromomethane 0.2 140 < 0.2 [+] Expand Test Data
Year Test Date MRL HRL Test Result
2014 2014-01-15 0.2 140 < 0.2
2014 2014-01-15 0.2 140 < 0.2
2013 2013-07-09 0.2 140 < 0.2
2013 2013-07-09 0.2 140 < 0.2
PFNA 0.02 0 < 0.02 [+] Expand Test Data
Year Test Date MRL HRL Test Result
2014 2014-01-15 0.02 0 < 0.02
2014 2014-01-15 0.02 0 < 0.02
2013 2013-07-24 0.02 0 < 0.02
2013 2013-07-24 0.02 0 < 0.02
PFHxS 0.03 0 < 0.03 [+] Expand Test Data
Year Test Date MRL HRL Test Result
2014 2014-01-15 0.03 0 < 0.03
2014 2014-01-15 0.03 0 < 0.03
2013 2013-07-24 0.03 0 < 0.03
2013 2013-07-24 0.03 0 < 0.03
PFHpA 0.01 0 < 0.01 [+] Expand Test Data
Year Test Date MRL HRL Test Result
2014 2014-01-15 0.01 0 < 0.01
2014 2014-01-15 0.01 0 < 0.01
2013 2013-07-24 0.01 0 < 0.01
2013 2013-07-24 0.01 0 < 0.01
PFOA 0.02 0.07 < 0.02 [+] Expand Test Data
Year Test Date MRL HRL Test Result
2014 2014-01-15 0.02 0.07 < 0.02
2014 2014-01-15 0.02 0.07 < 0.02
2013 2013-07-24 0.02 0.07 < 0.02
2013 2013-07-24 0.02 0.07 < 0.02
PFOS 0.04 0.07 < 0.04 [+] Expand Test Data
Year Test Date MRL HRL Test Result
2014 2014-01-15 0.04 0.07 < 0.04
2014 2014-01-15 0.04 0.07 < 0.04
2013 2013-07-24 0.04 0.07 < 0.04
2013 2013-07-24 0.04 0.07 < 0.04
PFBS 0.09 0 < 0.09 [+] Expand Test Data
Year Test Date MRL HRL Test Result
2014 2014-01-15 0.09 0 < 0.09
2014 2014-01-15 0.09 0 < 0.09
2013 2013-07-24 0.09 0 < 0.09
2013 2013-07-24 0.09 0 < 0.09
chromium 0.2 100 0.365 [+] Expand Test Data
Year Test Date MRL HRL Test Result
2014 2014-01-15 0.2 100 0.3
2014 2014-01-15 0.2 100 0.35
2014 2014-01-15 0.2 100 0.44
2014 2014-01-15 0.2 100 0.29
2013 2013-07-09 0.2 100 0.34
2013 2013-07-09 0.2 100 0.31
2013 2013-07-09 0.2 100 0.44
2013 2013-07-09 0.2 100 0.45
strontium 0.3 1500 186.1375 [+] Expand Test Data
Year Test Date MRL HRL Test Result
2014 2014-01-15 0.3 1500 123
2014 2014-01-15 0.3 1500 122
2014 2014-01-15 0.3 1500 349
2014 2014-01-15 0.3 1500 99.1
2013 2013-07-09 0.3 1500 153
2013 2013-07-09 0.3 1500 128
2013 2013-07-09 0.3 1500 262
2013 2013-07-09 0.3 1500 253
chromium-6 0.03 0 0.2113 [+] Expand Test Data
Year Test Date MRL HRL Test Result
2014 2014-01-15 0.03 0 0.14
2014 2014-01-15 0.03 0 0.14
2014 2014-01-15 0.03 0 0.25
2014 2014-01-15 0.03 0 0.13
2013 2013-07-09 0.03 0 0.19
2013 2013-07-09 0.03 0 0.19
2013 2013-07-09 0.03 0 0.32
2013 2013-07-09 0.03 0 0.33
cobalt 1 70 < 1 [+] Expand Test Data
Year Test Date MRL HRL Test Result
2014 2014-01-15 1 70 < 1
2014 2014-01-15 1 70 < 1
2014 2014-01-15 1 70 < 1
2014 2014-01-15 1 70 < 1
2013 2013-07-09 1 70 < 1
2013 2013-07-09 1 70 < 1
2013 2013-07-09 1 70 < 1
2013 2013-07-09 1 70 < 1
molybdenum 1 40 < 1 [+] Expand Test Data
Year Test Date MRL HRL Test Result
2014 2014-01-15 1 40 < 1
2014 2014-01-15 1 40 < 1
2014 2014-01-15 1 40 < 1
2014 2014-01-15 1 40 < 1
2013 2013-07-09 1 40 < 1
2013 2013-07-09 1 40 < 1
2013 2013-07-09 1 40 < 1
2013 2013-07-09 1 40 < 1
1,4-dioxane 0.07 0.35 0.0405 [+] Expand Test Data
Year Test Date MRL HRL Test Result
2014 2014-01-15 0.07 0.35 0.078
2014 2014-01-15 0.07 0.35 0.084
2013 2013-07-09 0.07 0.35 < 0.07
2013 2013-07-09 0.07 0.35 < 0.07
chloromethane 0.2 2.69 < 0.2 [+] Expand Test Data
Year Test Date MRL HRL Test Result
2014 2014-01-15 0.2 2.69 < 0.2
2014 2014-01-15 0.2 2.69 < 0.2
2013 2013-07-09 0.2 2.69 < 0.2
2013 2013-07-09 0.2 2.69 < 0.2
Halon 1011 0.06 90 < 0.06 [+] Expand Test Data
Year Test Date MRL HRL Test Result
2014 2014-01-15 0.06 90 < 0.06
2014 2014-01-15 0.06 90 < 0.06
2013 2013-07-09 0.06 90 < 0.06
2013 2013-07-09 0.06 90 < 0.06
1,3-butadiene 0.1 0.0103 < 0.1 [+] Expand Test Data
Year Test Date MRL HRL Test Result
2014 2014-01-15 0.1 0.0103 < 0.1
2014 2014-01-15 0.1 0.0103 < 0.1
2013 2013-07-09 0.1 0.0103 < 0.1
2013 2013-07-09 0.1 0.0103 < 0.1
HCFC-22 0.08 0 < 0.08 [+] Expand Test Data
Year Test Date MRL HRL Test Result
2014 2014-01-15 0.08 0 < 0.08
2014 2014-01-15 0.08 0 < 0.08
2013 2013-07-09 0.08 0 < 0.08
2013 2013-07-09 0.08 0 < 0.08
1,1-dichloroethane 0.03 6.14 0.022 [+] Expand Test Data
Year Test Date MRL HRL Test Result
2014 2014-01-15 0.03 6.14 < 0.03
2014 2014-01-15 0.03 6.14 0.046
2013 2013-07-09 0.03 6.14 0.042
2013 2013-07-09 0.03 6.14 < 0.03
vanadium 0.2 21 < 0.2 [+] Expand Test Data
Year Test Date MRL HRL Test Result
2014 2014-01-15 0.2 21 < 0.2
2014 2014-01-15 0.2 21 < 0.2
2014 2014-01-15 0.2 21 < 0.2
2014 2014-01-15 0.2 21 < 0.2
2013 2013-07-09 0.2 21 < 0.2
2013 2013-07-09 0.2 21 < 0.2
2013 2013-07-09 0.2 21 < 0.2
2013 2013-07-09 0.2 21 < 0.2

Lead and Copper Data


Lead and copper are recorded separately from other contaminants because of the Lead and Copper Rule. As with all other results, these are the findings at the water supply. Lead and copper can be — and often are — added to drinking water in between the water facility and a tap.

Sample ID Contaminant Sampling Start Date Sampling End Date Result
MD81212 lead 2013-01-01 2015-12-31 0mg/L
MD28060 lead 2010-01-01 2012-12-31 0mg/L
MD30810 lead 2007-01-01 2009-12-31 0.003mg/L

Violations


Known violations of the Safe Drinking Water Act as recorded by the EPA.

Compliance Dates Rule Violation Type Contaminant Name Status
2004-07-01 - 2004-09-30 Stage 1 Disinfectants and Disinfection Byproducts Rule Monitoring and Reporting (DBP) TTHM Returned to Compliance
2004-07-01 - 2004-09-30 Stage 1 Disinfectants and Disinfection Byproducts Rule Monitoring and Reporting (DBP) Total Haloacetic Acids (HAA5) Returned to Compliance
1998-01-01 - 1998-12-31 Nitrates Monitoring, Regular Nitrate Returned to Compliance
2013-07-01 - N/A Consumer Confidence Rule Consumer Confidence Report Inadequate Reporting Consumer Confidence Rule Returned to Compliance
2013-01-01 - N/A Lead and Copper Rule Lead Consumer Notice Lead and Copper Rule Returned to Compliance

What My Water Data Means


Water data isn't always easy to interpret, but by following the links on this page you should be able to have most of your questions answered. By clicking the name of a water contaminant or secondary substance you can learn about that specific substance. Ultimately this page should give you some insight towards learning if your water is safe, what water filter you should buy (if any), and how well your local water compares against other sources.

Sources


The origin of MyTapWater.org's water data is explained on our Data Sources page.

Why Is My Water Data Not More Recent?


The recency of the data for your ZIP code depends on the last your water source was tested, by a federal, state, or local agency. More information about the timing can be determined by learning about the dataset in question and seeing how often the EPA (other another governing body) mandated testing.