Springfield Water Works Water System

MyTapWater.org's tap water quality report is the compilation of data collected from federal, state, and local government agencies, most prominently the EPA. We strive to populate the report with the latest data concerning water contaminants, lead and copper levels, and water quality violations. We only collect drinking water data from public water systems.

PWS Service Information
PWS ID: KY1150415
Type: Community water system
EPA Region: 04
Primary Service Area: Residential Area
Primary Source: Surface water
Population Served: 13,205
Contact Information
BARTLEY, DAVID
BARTLEY, DAVID
PO BOX 307
SPRINGFIELD, KY 40069
[email protected]

This public water system services 1 municipality in 1 county.

Summary Results


A summary view of tests in which a water contaminant found to exceed the Maximum Contaminant Level (MCL) set by the EPA.

We couldn't find any records of contaminants exceeding the regulated limits in your water.

Other Water Contaminants Tested


The following contaminants were tested and found to be within national EPA guidelines.

We couldn't find any records of contaminants in your water.

Lead and Copper Data


Lead and copper are recorded separately from other contaminants because of the Lead and Copper Rule. As with all other results, these are the findings at the water supply level. Lead and copper can be — and often are — deposited in drinking water in between the water facility and your tap.

Sample ID Contaminant Sampling Start Date Sampling End Date Result
KY11022 lead 2014-01-01 2016-12-31 0.007mg/L
KY9272 lead 2011-01-01 2013-12-31 0.005mg/L
KY7414 lead 2008-01-01 2010-12-31 0.003mg/L

Violations


Known violations of the Safe Drinking Water Act as recorded by the EPA.

Compliance Dates Rule Violation Type Contaminant Name Status
2007-07-01 - 2007-09-30 Stage 1 Disinfectants and Disinfection Byproducts Rule Monitoring and Reporting (DBP) TTHM Returned to Compliance
2007-07-01 - 2007-09-30 Stage 1 Disinfectants and Disinfection Byproducts Rule Monitoring and Reporting (DBP) Total Haloacetic Acids (HAA5) Returned to Compliance
2005-04-01 - 2005-06-30 Stage 1 Disinfectants and Disinfection Byproducts Rule Maximum Contaminant Level Violation, Average Total Haloacetic Acids (HAA5) Returned to Compliance
2005-01-01 - 2005-03-31 Stage 1 Disinfectants and Disinfection Byproducts Rule Maximum Contaminant Level Violation, Average Total Haloacetic Acids (HAA5) Returned to Compliance
2005-01-01 - 2005-03-31 Stage 1 Disinfectants and Disinfection Byproducts Rule Maximum Contaminant Level Violation, Average TTHM Returned to Compliance
2004-10-01 - 2004-12-31 Stage 1 Disinfectants and Disinfection Byproducts Rule Maximum Contaminant Level Violation, Average TTHM Returned to Compliance
2004-10-01 - 2004-12-31 Stage 1 Disinfectants and Disinfection Byproducts Rule Maximum Contaminant Level Violation, Average Total Haloacetic Acids (HAA5) Returned to Compliance
2003-04-01 - 2003-04-30 Total Coliform Rule Monitoring, Routine Minor (TCR) Coliform (TCR) Returned to Compliance
2001-07-01 - 2001-07-31 Surface Water Treatment Rule Monitoring of Treatment (SWTR-Filter) Surface Water Treatment Rule Returned to Compliance
- N/A Surface Water Treatment Rule Treatment Technique (SWTR and GWR) Surface Water Treatment Rule Returned to Compliance
- N/A Surface Water Treatment Rule Monitoring of Treatment (SWTR-Filter) Surface Water Treatment Rule Returned to Compliance
- N/A Inorganic Chemicals Monitoring, Regular Selenium Known
- N/A Nitrates Monitoring, Regular Nitrate Returned to Compliance
- N/A Nitrates Monitoring, Regular Nitrate Known
- N/A Inorganic Chemicals Monitoring, Regular Mercury Known
- N/A Inorganic Chemicals Monitoring, Regular Chromium Known
- N/A Inorganic Chemicals Monitoring, Regular Cadmium Known
- N/A Inorganic Chemicals Monitoring, Regular Barium Known
- N/A Arsenic Monitoring, Regular Arsenic Known

Local Water Testing


Find a lab in your area so you can get your tap or well water tested. This list contains both governmental and private labs, all of which are EPA-certified for drinking water testing.

Unable to identify any nearby water testing labs near 40069.

Water Bill Information


Convenient information about your water service.

Unable to identify any billing information about Springfield Water Works (KY1150415).

What My Water Data Means


Water data isn't always easy to interpret, but by following the links on this page you should be able to have most of your questions answered. By clicking the name of a water contaminant or secondary substance you can learn about that specific substance. Ultimately this page should give you some insight towards learning if your water is safe, what water filter you should buy (if any), and how well your local water compares against other sources.

Sources


The origin of MyTapWater.org's water data is explained on our Data Sources page.

Why Is My Water Data Not More Recent?


The recency of the data for your ZIP code depends on the last your water source was tested, by a federal, state, or local agency. More information about the timing can be determined by learning about the dataset in question and seeing how often the EPA (other another governing body) mandated testing.