Thomaston Water System

MyTapWater.org's tap water quality report is the compilation of data collected from federal, state, and local government agencies, most prominently the EPA. We strive to populate the report with the latest data concerning water contaminants, lead and copper levels, and water quality violations. We only collect drinking water data from public water systems.

PWS Service Information
PWS ID: GA2930000
Type: Community water system
EPA Region: 04
Primary Service Area: Municipality
Primary Source: Surface water
Population Served: 12,482
Contact Information
THOMPSON, RUSSELL
THOMPSON, RUSSELL
P.O. BOX 672
THOMASTON, GA 30286

This public water system services 1 municipality in 1 county.

Summary Results


A summary view of tests in which a water contaminant found to exceed the Maximum Contaminant Level (MCL) set by the EPA.

Maximum Contaminant Levels Exceeded (by year):

2013   (0) 2014   (0) 2015   (0) 2016   (0) 2017   (0) 2018   (2)
germanium
manganese

Contaminant Detailed Results


This a view of violations of maximum contaminant levels. Use the expanded view see result data for a drinking water contaminant, the minimum level that can be recognized in a test (MRL), and upper limit that is considered healthy (HRL).

germanium

Year Test Date MRLMinimum Reporting Level HRLHealth Risk Limit Test Result
2018 2018-05-10 0.3 0.00 < 0.3
2018 2018-02-20 0.3 0.00 < 0.3

manganese

Year Test Date MRLMinimum Reporting Level HRLHealth Risk Limit Test Result
2018 2018-05-10 0.4 0.00 3.6
2018 2018-02-20 0.4 0.00 8.2

Other Water Contaminants Tested


The following contaminants were tested and found to be within national EPA guidelines.

Contaminant MRLMinimum Reporting Level HRLHealth Risk Limit Avg Result
chlorate 20 210 < 20 [+] Expand Test Data
Year Test Date MRL HRL Test Result
2014 2014-11-19 20 210 < 20
2014 2014-11-19 20 210 < 20
2014 2014-08-27 20 210 < 20
2014 2014-08-27 20 210 < 20
2014 2014-05-21 20 210 < 20
2014 2014-05-21 20 210 < 20
2014 2014-02-18 20 210 < 20
2014 2014-02-18 20 210 < 20
chromium 0.2 100 0.025 [+] Expand Test Data
Year Test Date MRL HRL Test Result
2014 2014-11-19 0.2 100 < 0.2
2014 2014-11-19 0.2 100 < 0.2
2014 2014-08-27 0.2 100 0.2
2014 2014-08-27 0.2 100 < 0.2
2014 2014-05-21 0.2 100 < 0.2
2014 2014-05-21 0.2 100 < 0.2
2014 2014-02-18 0.2 100 < 0.2
2014 2014-02-18 0.2 100 < 0.2
chromium-6 0.03 0 0.0788 [+] Expand Test Data
Year Test Date MRL HRL Test Result
2014 2014-11-19 0.03 0 0.12
2014 2014-11-19 0.03 0 < 0.03
2014 2014-08-27 0.03 0 0.21
2014 2014-08-27 0.03 0 < 0.03
2014 2014-05-21 0.03 0 0.15
2014 2014-05-21 0.03 0 0.06
2014 2014-02-18 0.03 0 0.09
2014 2014-02-18 0.03 0 < 0.03
cobalt 1 70 < 1 [+] Expand Test Data
Year Test Date MRL HRL Test Result
2014 2014-11-19 1 70 < 1
2014 2014-11-19 1 70 < 1
2014 2014-08-27 1 70 < 1
2014 2014-08-27 1 70 < 1
2014 2014-05-21 1 70 < 1
2014 2014-05-21 1 70 < 1
2014 2014-02-18 1 70 < 1
2014 2014-02-18 1 70 < 1
molybdenum 1 40 < 1 [+] Expand Test Data
Year Test Date MRL HRL Test Result
2014 2014-11-19 1 40 < 1
2014 2014-11-19 1 40 < 1
2014 2014-08-27 1 40 < 1
2014 2014-08-27 1 40 < 1
2014 2014-05-21 1 40 < 1
2014 2014-05-21 1 40 < 1
2014 2014-02-18 1 40 < 1
2014 2014-02-18 1 40 < 1
strontium 0.3 1500 21.625 [+] Expand Test Data
Year Test Date MRL HRL Test Result
2014 2014-11-19 0.3 1500 27
2014 2014-11-19 0.3 1500 20
2014 2014-08-27 0.3 1500 31
2014 2014-08-27 0.3 1500 21
2014 2014-05-21 0.3 1500 21
2014 2014-05-21 0.3 1500 16
2014 2014-02-18 0.3 1500 22
2014 2014-02-18 0.3 1500 15
vanadium 0.2 21 0.025 [+] Expand Test Data
Year Test Date MRL HRL Test Result
2014 2014-11-19 0.2 21 < 0.2
2014 2014-11-19 0.2 21 < 0.2
2014 2014-08-27 0.2 21 0.2
2014 2014-08-27 0.2 21 < 0.2
2014 2014-05-21 0.2 21 < 0.2
2014 2014-05-21 0.2 21 < 0.2
2014 2014-02-18 0.2 21 < 0.2
2014 2014-02-18 0.2 21 < 0.2
1,1-dichloroethane 0.03 6.14 < 0.03 [+] Expand Test Data
Year Test Date MRL HRL Test Result
2014 2014-11-19 0.03 6.14 < 0.03
2014 2014-08-27 0.03 6.14 < 0.03
2014 2014-05-21 0.03 6.14 < 0.03
2014 2014-02-18 0.03 6.14 < 0.03
1,2,3-trichloropropane 0.03 0.0004 < 0.03 [+] Expand Test Data
Year Test Date MRL HRL Test Result
2014 2014-11-19 0.03 0.0004 < 0.03
2014 2014-08-27 0.03 0.0004 < 0.03
2014 2014-05-21 0.03 0.0004 < 0.03
2014 2014-02-18 0.03 0.0004 < 0.03
1,3-butadiene 0.1 0.0103 < 0.1 [+] Expand Test Data
Year Test Date MRL HRL Test Result
2014 2014-11-19 0.1 0.0103 < 0.1
2014 2014-08-27 0.1 0.0103 < 0.1
2014 2014-05-21 0.1 0.0103 < 0.1
2014 2014-02-18 0.1 0.0103 < 0.1
1,4-dioxane 0.07 0.35 < 0.07 [+] Expand Test Data
Year Test Date MRL HRL Test Result
2014 2014-11-19 0.07 0.35 < 0.07
2014 2014-08-27 0.07 0.35 < 0.07
2014 2014-05-21 0.07 0.35 < 0.07
2014 2014-02-18 0.07 0.35 < 0.07
bromomethane 0.2 140 < 0.2 [+] Expand Test Data
Year Test Date MRL HRL Test Result
2014 2014-11-19 0.2 140 < 0.2
2014 2014-08-27 0.2 140 < 0.2
2014 2014-05-21 0.2 140 < 0.2
2014 2014-02-18 0.2 140 < 0.2
chloromethane 0.2 2.69 < 0.2 [+] Expand Test Data
Year Test Date MRL HRL Test Result
2014 2014-11-19 0.2 2.69 < 0.2
2014 2014-08-27 0.2 2.69 < 0.2
2014 2014-05-21 0.2 2.69 < 0.2
2014 2014-02-18 0.2 2.69 < 0.2
Halon 1011 0.06 90 < 0.06 [+] Expand Test Data
Year Test Date MRL HRL Test Result
2014 2014-11-19 0.06 90 < 0.06
2014 2014-08-27 0.06 90 < 0.06
2014 2014-05-21 0.06 90 < 0.06
2014 2014-02-18 0.06 90 < 0.06
HCFC-22 0.08 0 < 0.08 [+] Expand Test Data
Year Test Date MRL HRL Test Result
2014 2014-11-19 0.08 0 < 0.08
2014 2014-08-27 0.08 0 < 0.08
2014 2014-05-21 0.08 0 < 0.08
2014 2014-02-18 0.08 0 < 0.08
PFBS 0.09 0 < 0.09 [+] Expand Test Data
Year Test Date MRL HRL Test Result
2014 2014-11-19 0.09 0 < 0.09
2014 2014-08-27 0.09 0 < 0.09
2014 2014-05-21 0.09 0 < 0.09
2014 2014-02-18 0.09 0 < 0.09
PFHpA 0.01 0 < 0.01 [+] Expand Test Data
Year Test Date MRL HRL Test Result
2014 2014-11-19 0.01 0 < 0.01
2014 2014-08-27 0.01 0 < 0.01
2014 2014-05-21 0.01 0 < 0.01
2014 2014-02-18 0.01 0 < 0.01
PFHxS 0.03 0 < 0.03 [+] Expand Test Data
Year Test Date MRL HRL Test Result
2014 2014-11-19 0.03 0 < 0.03
2014 2014-08-27 0.03 0 < 0.03
2014 2014-05-21 0.03 0 < 0.03
2014 2014-02-18 0.03 0 < 0.03
PFNA 0.02 0 < 0.02 [+] Expand Test Data
Year Test Date MRL HRL Test Result
2014 2014-11-19 0.02 0 < 0.02
2014 2014-08-27 0.02 0 < 0.02
2014 2014-05-21 0.02 0 < 0.02
2014 2014-02-18 0.02 0 < 0.02
PFOA 0.02 0.07 < 0.02 [+] Expand Test Data
Year Test Date MRL HRL Test Result
2014 2014-11-19 0.02 0.07 < 0.02
2014 2014-08-27 0.02 0.07 < 0.02
2014 2014-05-21 0.02 0.07 < 0.02
2014 2014-02-18 0.02 0.07 < 0.02
PFOS 0.04 0.07 < 0.04 [+] Expand Test Data
Year Test Date MRL HRL Test Result
2014 2014-11-19 0.04 0.07 < 0.04
2014 2014-08-27 0.04 0.07 < 0.04
2014 2014-05-21 0.04 0.07 < 0.04
2014 2014-02-18 0.04 0.07 < 0.04

Lead and Copper Data


Lead and copper are recorded separately from other contaminants because of the Lead and Copper Rule. As with all other results, these are the findings at the water supply level. Lead and copper can be — and often are — deposited in drinking water in between the water facility and your tap.

Sample ID Contaminant Sampling Start Date Sampling End Date Result
GA62612 lead 2016-01-01 2018-12-31 0.00054mg/L
GA52284 lead 2015-01-01 2017-12-31 0mg/L
GA39054 lead 2011-01-01 2013-12-31 0mg/L
GA29744 lead 2008-01-01 2010-12-31 0mg/L

Violations


Known violations of the Safe Drinking Water Act as recorded by the EPA.

Compliance Dates Rule Violation Type Contaminant Name Status
2015-01-01 - 2015-03-31 Stage 2 Disinfectants and Disinfection Byproducts Rule Maximum Contaminant Level Violation, Average TTHM Returned to Compliance
2014-10-01 - 2014-12-31 Stage 2 Disinfectants and Disinfection Byproducts Rule Maximum Contaminant Level Violation, Average TTHM Returned to Compliance
2014-07-01 - 2014-09-30 Stage 2 Disinfectants and Disinfection Byproducts Rule Maximum Contaminant Level Violation, Average TTHM Known
2014-07-01 - 2014-09-30 Stage 2 Disinfectants and Disinfection Byproducts Rule Maximum Contaminant Level Violation, Average TTHM Returned to Compliance
2012-11-01 - 2012-11-30 Total Coliform Rule Monitoring, Routine Major (TCR) Coliform (TCR) Known
2012-10-01 - 2012-10-31 Total Coliform Rule Monitoring, Routine Major (TCR) Coliform (TCR) Known
2012-09-01 - 2012-09-30 Total Coliform Rule Monitoring, Routine Major (TCR) Coliform (TCR) Known
2010-02-01 - 2010-02-28 Long Term 1 Enhanced Surface Water Treatment Rule Single Turbidity Exceed (Enhanced SWTR) Interim Enhanced Surfsce Water Treatment Rule Returned to Compliance
2010-02-01 - 2010-02-28 Long Term 1 Enhanced Surface Water Treatment Rule Monitoring, Turbidity (Enhanced SWTR) Interim Enhanced Surfsce Water Treatment Rule Returned to Compliance
2009-12-01 - 2009-12-31 Long Term 1 Enhanced Surface Water Treatment Rule Monitoring, Turbidity (Enhanced SWTR) Interim Enhanced Surfsce Water Treatment Rule Returned to Compliance
2009-09-01 - 2009-09-30 Long Term 1 Enhanced Surface Water Treatment Rule Monitoring, Turbidity (Enhanced SWTR) Interim Enhanced Surfsce Water Treatment Rule Returned to Compliance
2002-10-01 - 2002-12-31 Stage 1 Disinfectants and Disinfection Byproducts Rule Maximum Contaminant Level Violation, Average Total Haloacetic Acids (HAA5) Returned to Compliance
2002-07-01 - 2002-07-08 Consumer Confidence Rule Consumer Confidence Report Complete Failure to Report Consumer Confidence Rule Returned to Compliance
- N/A Lead and Copper Rule Follow-up Or Routine LCR Tap M/R Lead and Copper Rule Open
2007-07-01 - N/A Consumer Confidence Rule Consumer Confidence Report Complete Failure to Report Consumer Confidence Rule Returned to Compliance
2010-07-01 - N/A Consumer Confidence Rule Consumer Confidence Report Complete Failure to Report Consumer Confidence Rule Returned to Compliance
2015-07-01 - N/A Consumer Confidence Rule Consumer Confidence Report Complete Failure to Report Consumer Confidence Rule Returned to Compliance

Local Water Testing


Find a lab in your area so you can get your tap or well water tested. This list contains both governmental and private labs, all of which are EPA-certified for drinking water testing.

Lab Location Zip Code
Analytical Environmental Services, Inc. Atlanta, GA 30340
City of Atlanta, Department of Watershed Management, Wastewater Laboratory Atlanta, GA 30336
Georgia Power Environmental Laboratory Atlanta, GA 30339

Water Bill Information


Convenient information about your water service.

Unable to identify any billing information about Thomaston (GA2930000).

What My Water Data Means


Water data isn't always easy to interpret, but by following the links on this page you should be able to have most of your questions answered. By clicking the name of a water contaminant or secondary substance you can learn about that specific substance. Ultimately this page should give you some insight towards learning if your water is safe, what water filter you should buy (if any), and how well your local water compares against other sources.

Sources


The origin of MyTapWater.org's water data is explained on our Data Sources page.

Why Is My Water Data Not More Recent?


The recency of the data for your ZIP code depends on the last your water source was tested, by a federal, state, or local agency. More information about the timing can be determined by learning about the dataset in question and seeing how often the EPA (other another governing body) mandated testing.