Public Water System: Fillmore Water Dept

MyTapWater.org's tap water quality report is the compilation of data collected from federal, state, and local government agencies, most prominently the EPA. We strive to populate the report with the latest data concerning water contaminants, lead and copper levels, and water quality violations. We only collect drinking water data from public water systems.

PWS Service Information
PWS ID: CA5610002
Type: Community water system
EPA Region: 09
Primary Service Area: Residential Area
Primary Source: Ground water
Population Served: 15,222
Contact Information
SMALLWOOD, DAVID
SMALLWOOD, DAVID
250 Central Avenue Central Park Plaza
FILLMORE, CA 93015

This public water system services 1 zip code in 1 municipality in 1 county.

Summary Results


A summary view of the the times a water contaminant was tested and found to exceed the level set by the EPA (the MCL).

Maximum Contaminant Levels Exceeded (by year):

2013   (0) 2014   (0) 2015   (2)
strontium
chlorate

Contaminant Detailed Results


This a view of violations of maximum contaminant levels. In the expanded view you can see each know test date for a given contaminant, the result of the test, the minimum level that can be recognized in a test (MRL), and upper limit that is considered healthy (HRL).

strontium
Is this in your home's pipes?

Year Test Date MRL HRL Test Result
2016 2016-06-07 0.3 1500 2100
2016 2016-06-07 0.3 1500 2100
2016 2016-06-07 0.3 1500 1700
2016 2016-06-07 0.3 1500 1700
2016 2016-06-07 0.3 1500 1700
2016 2016-06-07 0.3 1500 1900
2015 2015-12-28 0.3 1500 2000
2015 2015-12-28 0.3 1500 1800
2015 2015-12-28 0.3 1500 1800
2015 2015-12-28 0.3 1500 1900
2015 2015-12-28 0.3 1500 2100
2015 2015-12-28 0.3 1500 1900

molybdenum
Is this in your home's pipes?

Year Test Date MRL HRL Test Result
2016 2016-06-07 1 40 61
2016 2016-06-07 1 40 53
2016 2016-06-07 1 40 13
2016 2016-06-07 1 40 21
2016 2016-06-07 1 40 13
2016 2016-06-07 1 40 19
2015 2015-12-28 1 40 37
2015 2015-12-28 1 40 24
2015 2015-12-28 1 40 36
2015 2015-12-28 1 40 18
2015 2015-12-28 1 40 27
2015 2015-12-28 1 40 18

chlorate
Is this in your home's pipes?

Year Test Date MRL HRL Test Result
2016 2016-06-07 20 210 25
2016 2016-06-07 20 210 150
2016 2016-06-07 20 210 560
2016 2016-06-07 20 210 390
2016 2016-06-07 20 210 < 20
2016 2016-06-07 20 210 < 20
2015 2015-12-28 20 210 200
2015 2015-12-28 20 210 170
2015 2015-12-28 20 210 220
2015 2015-12-28 20 210 260
2015 2015-12-28 20 210 150
2015 2015-12-28 20 210 220

Other Water Contaminants Tested


The following contaminants were tested and within national EPA guidelines.

The last mile of pipe makes a big difference, learn more about testing your water.

Contaminant MRL HRL Avg Result
1,2,3-trichloropropane 0.03 0.0004 < 0.03 [+] Expand Test Data
Year Test Date MRL HRL Test Result
2016 2016-06-07 0.03 0.0004 < 0.03
2016 2016-06-07 0.03 0.0004 < 0.03
2016 2016-06-07 0.03 0.0004 < 0.03
2016 2016-01-21 0.03 0.0004 < 0.03
2016 2016-01-21 0.03 0.0004 < 0.03
2016 2016-01-21 0.03 0.0004 < 0.03
bromomethane 0.2 140 < 0.2 [+] Expand Test Data
Year Test Date MRL HRL Test Result
2016 2016-06-07 0.2 140 < 0.2
2016 2016-06-07 0.2 140 < 0.2
2016 2016-06-07 0.2 140 < 0.2
2016 2016-01-21 0.2 140 < 0.2
2016 2016-01-21 0.2 140 < 0.2
2016 2016-01-21 0.2 140 < 0.2
PFOA 0.02 0.07 < 0.02 [+] Expand Test Data
Year Test Date MRL HRL Test Result
2016 2016-06-07 0.02 0.07 < 0.02
2016 2016-06-07 0.02 0.07 < 0.02
2016 2016-06-07 0.02 0.07 < 0.02
2015 2015-12-28 0.02 0.07 < 0.02
2015 2015-12-28 0.02 0.07 < 0.02
2015 2015-12-28 0.02 0.07 < 0.02
HCFC-22 0.08 0 < 0.08 [+] Expand Test Data
Year Test Date MRL HRL Test Result
2016 2016-06-07 0.08 0 < 0.08
2016 2016-06-07 0.08 0 < 0.08
2016 2016-06-07 0.08 0 < 0.08
2016 2016-01-21 0.08 0 < 0.08
2016 2016-01-21 0.08 0 < 0.08
2016 2016-01-21 0.08 0 < 0.08
vanadium 0.2 21 1.05 [+] Expand Test Data
Year Test Date MRL HRL Test Result
2016 2016-06-07 0.2 21 1.2
2016 2016-06-07 0.2 21 1.2
2016 2016-06-07 0.2 21 1
2016 2016-06-07 0.2 21 1
2016 2016-06-07 0.2 21 1.1
2016 2016-06-07 0.2 21 1.1
2015 2015-12-28 0.2 21 1.1
2015 2015-12-28 0.2 21 0.86
2015 2015-12-28 0.2 21 0.96
2015 2015-12-28 0.2 21 0.98
2015 2015-12-28 0.2 21 1
2015 2015-12-28 0.2 21 1.1
Halon 1011 0.06 90 < 0.06 [+] Expand Test Data
Year Test Date MRL HRL Test Result
2016 2016-06-07 0.06 90 < 0.06
2016 2016-06-07 0.06 90 < 0.06
2016 2016-06-07 0.06 90 < 0.06
2016 2016-01-21 0.06 90 < 0.06
2016 2016-01-21 0.06 90 < 0.06
2016 2016-01-21 0.06 90 < 0.06
chloromethane 0.2 2.69 < 0.2 [+] Expand Test Data
Year Test Date MRL HRL Test Result
2016 2016-06-07 0.2 2.69 < 0.2
2016 2016-06-07 0.2 2.69 < 0.2
2016 2016-06-07 0.2 2.69 < 0.2
2016 2016-01-21 0.2 2.69 < 0.2
2016 2016-01-21 0.2 2.69 < 0.2
2016 2016-01-21 0.2 2.69 < 0.2
chromium 0.2 100 0.1425 [+] Expand Test Data
Year Test Date MRL HRL Test Result
2016 2016-06-07 0.2 100 < 0.2
2016 2016-06-07 0.2 100 0.6
2016 2016-06-07 0.2 100 < 0.2
2016 2016-06-07 0.2 100 0.42
2016 2016-06-07 0.2 100 0.48
2016 2016-06-07 0.2 100 0.21
2015 2015-12-28 0.2 100 < 0.2
2015 2015-12-28 0.2 100 < 0.2
2015 2015-12-28 0.2 100 < 0.2
2015 2015-12-28 0.2 100 < 0.2
2015 2015-12-28 0.2 100 < 0.2
2015 2015-12-28 0.2 100 < 0.2
chromium-6 0.03 0 0.1002 [+] Expand Test Data
Year Test Date MRL HRL Test Result
2016 2016-06-28 0.03 0 0.055
2016 2016-06-07 0.03 0 0.062
2016 2016-06-07 0.03 0 0.18
2016 2016-06-07 0.03 0 0.18
2016 2016-06-07 0.03 0 0.1
2016 2016-06-07 0.03 0 0.087
2015 2015-12-28 0.03 0 0.06
2015 2015-12-28 0.03 0 0.06
2015 2015-12-28 0.03 0 0.14
2015 2015-12-28 0.03 0 0.064
2015 2015-12-28 0.03 0 0.14
2015 2015-12-28 0.03 0 0.074
cobalt 1 70 < 1 [+] Expand Test Data
Year Test Date MRL HRL Test Result
2016 2016-06-07 1 70 < 1
2016 2016-06-07 1 70 < 1
2016 2016-06-07 1 70 < 1
2016 2016-06-07 1 70 < 1
2016 2016-06-07 1 70 < 1
2016 2016-06-07 1 70 < 1
2015 2015-12-28 1 70 < 1
2015 2015-12-28 1 70 < 1
2015 2015-12-28 1 70 < 1
2015 2015-12-28 1 70 < 1
2015 2015-12-28 1 70 < 1
2015 2015-12-28 1 70 < 1
PFBS 0.09 0 < 0.09 [+] Expand Test Data
Year Test Date MRL HRL Test Result
2016 2016-06-07 0.09 0 < 0.09
2016 2016-06-07 0.09 0 < 0.09
2016 2016-06-07 0.09 0 < 0.09
2015 2015-12-28 0.09 0 < 0.09
2015 2015-12-28 0.09 0 < 0.09
2015 2015-12-28 0.09 0 < 0.09
PFHpA 0.01 0 < 0.01 [+] Expand Test Data
Year Test Date MRL HRL Test Result
2016 2016-06-07 0.01 0 < 0.01
2016 2016-06-07 0.01 0 < 0.01
2016 2016-06-07 0.01 0 < 0.01
2015 2015-12-28 0.01 0 < 0.01
2015 2015-12-28 0.01 0 < 0.01
2015 2015-12-28 0.01 0 < 0.01
1,3-butadiene 0.1 0.0103 < 0.1 [+] Expand Test Data
Year Test Date MRL HRL Test Result
2016 2016-06-07 0.1 0.0103 < 0.1
2016 2016-06-07 0.1 0.0103 < 0.1
2016 2016-06-07 0.1 0.0103 < 0.1
2016 2016-01-21 0.1 0.0103 < 0.1
2016 2016-01-21 0.1 0.0103 < 0.1
2016 2016-01-21 0.1 0.0103 < 0.1
PFNA 0.02 0 < 0.02 [+] Expand Test Data
Year Test Date MRL HRL Test Result
2016 2016-06-07 0.02 0 < 0.02
2016 2016-06-07 0.02 0 < 0.02
2016 2016-06-07 0.02 0 < 0.02
2015 2015-12-28 0.02 0 < 0.02
2015 2015-12-28 0.02 0 < 0.02
2015 2015-12-28 0.02 0 < 0.02
1,4-dioxane 0.07 0.35 < 0.07 [+] Expand Test Data
Year Test Date MRL HRL Test Result
2016 2016-06-07 0.07 0.35 < 0.07
2016 2016-06-07 0.07 0.35 < 0.07
2016 2016-06-07 0.07 0.35 < 0.07
2015 2015-12-28 0.07 0.35 < 0.07
2015 2015-12-28 0.07 0.35 < 0.07
2015 2015-12-28 0.07 0.35 < 0.07
1,1-dichloroethane 0.03 6.14 < 0.03 [+] Expand Test Data
Year Test Date MRL HRL Test Result
2016 2016-06-07 0.03 6.14 < 0.03
2016 2016-06-07 0.03 6.14 < 0.03
2016 2016-06-07 0.03 6.14 < 0.03
2016 2016-01-21 0.03 6.14 < 0.03
2016 2016-01-21 0.03 6.14 < 0.03
2016 2016-01-21 0.03 6.14 < 0.03
PFOS 0.04 0.07 < 0.04 [+] Expand Test Data
Year Test Date MRL HRL Test Result
2016 2016-06-07 0.04 0.07 < 0.04
2016 2016-06-07 0.04 0.07 < 0.04
2016 2016-06-07 0.04 0.07 < 0.04
2015 2015-12-28 0.04 0.07 < 0.04
2015 2015-12-28 0.04 0.07 < 0.04
2015 2015-12-28 0.04 0.07 < 0.04
PFHxS 0.03 0 < 0.03 [+] Expand Test Data
Year Test Date MRL HRL Test Result
2016 2016-06-07 0.03 0 < 0.03
2016 2016-06-07 0.03 0 < 0.03
2016 2016-06-07 0.03 0 < 0.03
2015 2015-12-28 0.03 0 < 0.03
2015 2015-12-28 0.03 0 < 0.03
2015 2015-12-28 0.03 0 < 0.03

Lead and Copper Data


Lead and copper are recorded separately from other contaminants because of the Lead and Copper Rule. As with all other results, these are the findings at the water supply. Lead and copper can be — and often are — added to drinking water in between the water facility and a tap.

Sample ID Contaminant Sampling Start Date Sampling End Date Result
CA48972 lead 2013-01-01 2015-12-31 0.0027mg/L
CA37484 lead 2010-01-01 2012-12-31 0.0033mg/L
CA37501 lead 2012-01-01 2012-12-31 0mg/L
561000212229L lead 2012-01-01 2012-12-31 0.0033mg/L
561000209191L lead 2009-01-01 2009-12-31 0.0018mg/L
561000209191LT4 lead 2009-01-01 2009-12-31 0.0018mg/L

Violations


Known violations of the Safe Drinking Water Act as recorded by the EPA.

Compliance Dates Rule Violation Type Contaminant Name Status
2017-04-01 - 2017-04-30 Revised Total Coliform Rule Monitoring, Routine (RTCR) Revised Total Coliform Rule Known
2006-09-01 - 2006-09-30 Total Coliform Rule Maximum Contaminant Level Violation, Monthly (TCR) Coliform (TCR) Known
2004-03-01 - 2004-03-31 Total Coliform Rule Monitoring, Routine Minor (TCR) Coliform (TCR) Known
1998-07-01 - 1998-07-31 Total Coliform Rule Maximum Contaminant Level Violation, Monthly (TCR) Coliform (TCR) Returned to Compliance
2009-07-01 - N/A Consumer Confidence Rule Consumer Confidence Report Complete Failure to Report Consumer Confidence Rule Open

What My Water Data Means


Water data isn't always easy to interpret, but by following the links on this page you should be able to have most of your questions answered. By clicking the name of a water contaminant or secondary substance you can learn about that specific substance. Ultimately this page should give you some insight towards learning if your water is safe, what water filter you should buy (if any), and how well your local water compares against other sources.

Sources


The origin of MyTapWater.org's water data is explained on our Data Sources page.

Why Is My Water Data Not More Recent?


The recency of the data for your ZIP code depends on the last your water source was tested, by a federal, state, or local agency. More information about the timing can be determined by learning about the dataset in question and seeing how often the EPA (other another governing body) mandated testing.