MyTapWater.org's tap water quality report is the compilation of data collected from federal, state, and local government agencies, most prominently the EPA. We strive to populate the report with the latest data concerning water contaminants, lead and copper levels, and water quality violations. We only collect drinking water data from public water systems.

PWS Service Information
PWS ID: CA3010035
Type: Community water system
EPA Region: 09
Primary Service Area: Residential Area
Primary Source: Surface water purchased
Population Served: 36,374
Contact Information
CHEN, SAMANTHA
CHEN, SAMANTHA
1920 W Corporate Way
ANAHEIM, CA 92801

This public water system services 3 zip codes in 1 county.

Summary Results


A summary view of the the times a water contaminant was tested and found to exceed the level set by the EPA (the MCL).

Maximum Contaminant Levels Exceeded (by year):

2013   (3) 2014   (0) 2015   (0)
molybdenum
chlorate
1,4-dioxane

Contaminant Detailed Results


This a view of violations of maximum contaminant levels. In the expanded view you can see each know test date for a given contaminant, the result of the test, the minimum level that can be recognized in a test (MRL), and upper limit that is considered healthy (HRL).

molybdenum
Is this in your home's pipes?

Year Test Date MRL HRL Test Result
2014 2014-02-05 1 40 5
2013 2013-12-17 1 40 4.6
2013 2013-09-16 1 40 4.4
2013 2013-09-03 1 40 4.5
2013 2013-08-06 1 40 5.4
2013 2013-08-06 1 40 11
2013 2013-08-06 1 40 49
2013 2013-08-05 1 40 4.6
2013 2013-06-24 1 40 5
2013 2013-06-10 1 40 4.6
2013 2013-03-18 1 40 5.3
2013 2013-03-04 1 40 4.7
2013 2013-02-05 1 40 4.7
2013 2013-02-05 1 40 4.3
2013 2013-02-05 1 40 49.9
2013 2013-02-05 1 40 27.1
2013 2013-02-05 1 40 4.6

chlorate
Is this in your home's pipes?

Year Test Date MRL HRL Test Result
2013 2013-12-17 20 210 56.2
2013 2013-12-09 20 210 52.6
2013 2013-09-16 20 210 58.2
2013 2013-09-03 20 210 67.6
2013 2013-08-06 20 210 67
2013 2013-08-06 20 210 65.6
2013 2013-08-06 20 210 100
2013 2013-08-05 20 210 107
2013 2013-06-24 20 210 59.5
2013 2013-06-10 20 210 50.5
2013 2013-03-18 20 210 40.6
2013 2013-03-04 20 210 41.2
2013 2013-02-05 20 210 40.7
2013 2013-02-05 20 210 39.7
2013 2013-02-05 20 210 691
2013 2013-02-05 20 210 77.1
2013 2013-02-05 20 210 83.3

1,4-dioxane
Is this in your home's pipes?

Year Test Date MRL HRL Test Result
2013 2013-12-09 0.07 0.35 < 0.07
2013 2013-09-03 0.07 0.35 < 0.07
2013 2013-08-06 0.07 0.35 < 0.07
2013 2013-08-05 0.07 0.35 0.35
2013 2013-06-10 0.07 0.35 < 0.07
2013 2013-03-04 0.07 0.35 < 0.07
2013 2013-02-05 0.07 0.35 < 0.07
2013 2013-02-05 0.07 0.35 0.16
2013 2013-02-05 0.07 0.35 0.5

Other Water Contaminants Tested


The following contaminants were tested and within national EPA guidelines.

The last mile of pipe makes a big difference, learn more about testing your water.

Contaminant MRL HRL Avg Result
PFOS 0.04 0.07 < 0.04 [+] Expand Test Data
Year Test Date MRL HRL Test Result
2013 2013-12-09 0.04 0.07 < 0.04
2013 2013-09-03 0.04 0.07 < 0.04
2013 2013-08-06 0.04 0.07 < 0.04
2013 2013-08-05 0.04 0.07 < 0.04
2013 2013-06-10 0.04 0.07 < 0.04
2013 2013-03-04 0.04 0.07 < 0.04
2013 2013-02-28 0.04 0.07 < 0.04
2013 2013-02-28 0.04 0.07 < 0.04
PFOA 0.02 0.07 < 0.02 [+] Expand Test Data
Year Test Date MRL HRL Test Result
2013 2013-12-09 0.02 0.07 < 0.02
2013 2013-09-03 0.02 0.07 < 0.02
2013 2013-08-06 0.02 0.07 < 0.02
2013 2013-08-05 0.02 0.07 < 0.02
2013 2013-06-10 0.02 0.07 < 0.02
2013 2013-03-04 0.02 0.07 < 0.02
2013 2013-02-28 0.02 0.07 < 0.02
2013 2013-02-28 0.02 0.07 < 0.02
HCFC-22 0.08 0 < 0.08 [+] Expand Test Data
Year Test Date MRL HRL Test Result
2013 2013-12-09 0.08 0 < 0.08
2013 2013-09-03 0.08 0 < 0.08
2013 2013-08-06 0.08 0 < 0.08
2013 2013-08-05 0.08 0 < 0.08
2013 2013-06-10 0.08 0 < 0.08
2013 2013-03-04 0.08 0 < 0.08
2013 2013-02-05 0.08 0 < 0.08
2013 2013-02-05 0.08 0 < 0.08
2013 2013-02-05 0.08 0 < 0.08
1,2,3-trichloropropane 0.03 0.0004 < 0.03 [+] Expand Test Data
Year Test Date MRL HRL Test Result
2013 2013-12-09 0.03 0.0004 < 0.03
2013 2013-09-03 0.03 0.0004 < 0.03
2013 2013-08-06 0.03 0.0004 < 0.03
2013 2013-08-05 0.03 0.0004 < 0.03
2013 2013-06-10 0.03 0.0004 < 0.03
2013 2013-03-04 0.03 0.0004 < 0.03
2013 2013-02-05 0.03 0.0004 < 0.03
2013 2013-02-05 0.03 0.0004 < 0.03
2013 2013-02-05 0.03 0.0004 < 0.03
bromomethane 0.2 140 < 0.2 [+] Expand Test Data
Year Test Date MRL HRL Test Result
2013 2013-12-09 0.2 140 < 0.2
2013 2013-09-03 0.2 140 < 0.2
2013 2013-08-06 0.2 140 < 0.2
2013 2013-08-05 0.2 140 < 0.2
2013 2013-06-10 0.2 140 < 0.2
2013 2013-03-04 0.2 140 < 0.2
2013 2013-02-05 0.2 140 < 0.2
2013 2013-02-05 0.2 140 < 0.2
2013 2013-02-05 0.2 140 < 0.2
chromium 0.2 100 0.2529 [+] Expand Test Data
Year Test Date MRL HRL Test Result
2014 2014-02-05 0.2 100 0.5
2013 2013-12-17 0.2 100 < 0.2
2013 2013-09-16 0.2 100 < 0.2
2013 2013-09-03 0.2 100 < 0.2
2013 2013-08-06 0.2 100 0.3
2013 2013-08-06 0.2 100 < 0.2
2013 2013-08-06 0.2 100 1.3
2013 2013-08-05 0.2 100 < 0.2
2013 2013-06-24 0.2 100 < 0.2
2013 2013-06-10 0.2 100 < 0.2
2013 2013-03-18 0.2 100 < 0.2
2013 2013-03-04 0.2 100 < 0.2
2013 2013-02-05 0.2 100 < 0.2
2013 2013-02-05 0.2 100 < 0.2
2013 2013-02-05 0.2 100 2
2013 2013-02-05 0.2 100 < 0.2
2013 2013-02-05 0.2 100 0.2
strontium 0.3 1500 878.5294 [+] Expand Test Data
Year Test Date MRL HRL Test Result
2014 2014-02-05 0.3 1500 1070
2013 2013-12-17 0.3 1500 975
2013 2013-09-16 0.3 1500 930
2013 2013-09-03 0.3 1500 899
2013 2013-08-06 0.3 1500 1020
2013 2013-08-06 0.3 1500 1020
2013 2013-08-06 0.3 1500 984
2013 2013-08-05 0.3 1500 647
2013 2013-06-24 0.3 1500 1010
2013 2013-06-10 0.3 1500 901
2013 2013-03-18 0.3 1500 976
2013 2013-03-04 0.3 1500 854
2013 2013-02-05 0.3 1500 870
2013 2013-02-05 0.3 1500 880
2013 2013-02-05 0.3 1500 952
2013 2013-02-05 0.3 1500 144
2013 2013-02-05 0.3 1500 803
cobalt 1 70 < 1 [+] Expand Test Data
Year Test Date MRL HRL Test Result
2014 2014-02-05 1 70 < 1
2013 2013-12-17 1 70 < 1
2013 2013-09-16 1 70 < 1
2013 2013-09-03 1 70 < 1
2013 2013-08-06 1 70 < 1
2013 2013-08-06 1 70 < 1
2013 2013-08-06 1 70 < 1
2013 2013-08-05 1 70 < 1
2013 2013-06-24 1 70 < 1
2013 2013-06-10 1 70 < 1
2013 2013-03-18 1 70 < 1
2013 2013-03-04 1 70 < 1
2013 2013-02-05 1 70 < 1
2013 2013-02-05 1 70 < 1
2013 2013-02-05 1 70 < 1
2013 2013-02-05 1 70 < 1
2013 2013-02-05 1 70 < 1
vanadium 0.2 21 3.5118 [+] Expand Test Data
Year Test Date MRL HRL Test Result
2014 2014-02-05 0.2 21 2.3
2013 2013-12-17 0.2 21 2.4
2013 2013-09-16 0.2 21 3
2013 2013-09-03 0.2 21 2.9
2013 2013-08-06 0.2 21 3
2013 2013-08-06 0.2 21 3.4
2013 2013-08-06 0.2 21 6.1
2013 2013-08-05 0.2 21 3.6
2013 2013-06-24 0.2 21 2.8
2013 2013-06-10 0.2 21 3
2013 2013-03-18 0.2 21 3.1
2013 2013-03-04 0.2 21 2.8
2013 2013-02-05 0.2 21 2.9
2013 2013-02-05 0.2 21 3
2013 2013-02-05 0.2 21 7.3
2013 2013-02-05 0.2 21 4
2013 2013-02-05 0.2 21 4.1
1,3-butadiene 0.1 0.0103 < 0.1 [+] Expand Test Data
Year Test Date MRL HRL Test Result
2013 2013-12-09 0.1 0.0103 < 0.1
2013 2013-09-03 0.1 0.0103 < 0.1
2013 2013-08-06 0.1 0.0103 < 0.1
2013 2013-08-05 0.1 0.0103 < 0.1
2013 2013-06-10 0.1 0.0103 < 0.1
2013 2013-03-04 0.1 0.0103 < 0.1
2013 2013-02-05 0.1 0.0103 < 0.1
2013 2013-02-05 0.1 0.0103 < 0.1
2013 2013-02-05 0.1 0.0103 < 0.1
PFHxS 0.03 0 < 0.03 [+] Expand Test Data
Year Test Date MRL HRL Test Result
2013 2013-12-09 0.03 0 < 0.03
2013 2013-09-03 0.03 0 < 0.03
2013 2013-08-06 0.03 0 < 0.03
2013 2013-08-05 0.03 0 < 0.03
2013 2013-06-10 0.03 0 < 0.03
2013 2013-03-04 0.03 0 < 0.03
2013 2013-02-28 0.03 0 < 0.03
2013 2013-02-28 0.03 0 < 0.03
chromium-6 0.03 0 0.2524 [+] Expand Test Data
Year Test Date MRL HRL Test Result
2013 2013-12-17 0.03 0 0.03
2013 2013-12-09 0.03 0 0.03
2013 2013-09-16 0.03 0 0.06
2013 2013-09-03 0.03 0 0.06
2013 2013-08-06 0.03 0 0.26
2013 2013-08-06 0.03 0 0.07
2013 2013-08-06 0.03 0 1.56
2013 2013-08-05 0.03 0 0.19
2013 2013-06-24 0.03 0 0.07
2013 2013-06-10 0.03 0 0.08
2013 2013-03-18 0.03 0 0.11
2013 2013-03-04 0.03 0 0.11
2013 2013-02-05 0.03 0 0.07
2013 2013-02-05 0.03 0 0.07
2013 2013-02-05 0.03 0 1.2
2013 2013-02-05 0.03 0 0.11
2013 2013-02-05 0.03 0 0.21
PFNA 0.02 0 < 0.02 [+] Expand Test Data
Year Test Date MRL HRL Test Result
2013 2013-12-09 0.02 0 < 0.02
2013 2013-09-03 0.02 0 < 0.02
2013 2013-08-06 0.02 0 < 0.02
2013 2013-08-05 0.02 0 < 0.02
2013 2013-06-10 0.02 0 < 0.02
2013 2013-03-04 0.02 0 < 0.02
2013 2013-02-28 0.02 0 < 0.02
2013 2013-02-28 0.02 0 < 0.02
PFBS 0.09 0 < 0.09 [+] Expand Test Data
Year Test Date MRL HRL Test Result
2013 2013-12-09 0.09 0 < 0.09
2013 2013-09-03 0.09 0 < 0.09
2013 2013-08-06 0.09 0 < 0.09
2013 2013-08-05 0.09 0 < 0.09
2013 2013-06-10 0.09 0 < 0.09
2013 2013-03-04 0.09 0 < 0.09
2013 2013-02-28 0.09 0 < 0.09
2013 2013-02-28 0.09 0 < 0.09
1,1-dichloroethane 0.03 6.14 < 0.03 [+] Expand Test Data
Year Test Date MRL HRL Test Result
2013 2013-12-09 0.03 6.14 < 0.03
2013 2013-09-03 0.03 6.14 < 0.03
2013 2013-08-06 0.03 6.14 < 0.03
2013 2013-08-05 0.03 6.14 < 0.03
2013 2013-06-10 0.03 6.14 < 0.03
2013 2013-03-04 0.03 6.14 < 0.03
2013 2013-02-05 0.03 6.14 < 0.03
2013 2013-02-05 0.03 6.14 < 0.03
2013 2013-02-05 0.03 6.14 < 0.03
Halon 1011 0.06 90 < 0.06 [+] Expand Test Data
Year Test Date MRL HRL Test Result
2013 2013-12-09 0.06 90 < 0.06
2013 2013-09-03 0.06 90 < 0.06
2013 2013-08-06 0.06 90 < 0.06
2013 2013-08-05 0.06 90 < 0.06
2013 2013-06-10 0.06 90 < 0.06
2013 2013-03-04 0.06 90 < 0.06
2013 2013-02-05 0.06 90 < 0.06
2013 2013-02-05 0.06 90 < 0.06
2013 2013-02-05 0.06 90 < 0.06
PFHpA 0.01 0 < 0.01 [+] Expand Test Data
Year Test Date MRL HRL Test Result
2013 2013-12-09 0.01 0 < 0.01
2013 2013-09-03 0.01 0 < 0.01
2013 2013-08-06 0.01 0 < 0.01
2013 2013-08-05 0.01 0 < 0.01
2013 2013-06-10 0.01 0 < 0.01
2013 2013-03-04 0.01 0 < 0.01
2013 2013-02-28 0.01 0 < 0.01
2013 2013-02-28 0.01 0 < 0.01
chloromethane 0.2 2.69 < 0.2 [+] Expand Test Data
Year Test Date MRL HRL Test Result
2013 2013-12-09 0.2 2.69 < 0.2
2013 2013-09-03 0.2 2.69 < 0.2
2013 2013-08-06 0.2 2.69 < 0.2
2013 2013-08-05 0.2 2.69 < 0.2
2013 2013-06-10 0.2 2.69 < 0.2
2013 2013-03-04 0.2 2.69 < 0.2
2013 2013-02-05 0.2 2.69 < 0.2
2013 2013-02-05 0.2 2.69 < 0.2
2013 2013-02-05 0.2 2.69 < 0.2

Lead and Copper Data


Lead and copper are recorded separately from other contaminants because of the Lead and Copper Rule. As with all other results, these are the findings at the water supply. Lead and copper can be — and often are — added to drinking water in between the water facility and a tap.

Sample ID Contaminant Sampling Start Date Sampling End Date Result
CA55063 lead 2014-01-01 2016-12-31 0mg/L
CA39523 lead 2011-01-01 2013-12-31 0mg/L
301003510232L lead 2010-01-01 2010-12-31 0.0022mg/L

Violations


Known violations of the Safe Drinking Water Act as recorded by the EPA.

No violations found for Golden State Wc - Placentia.


What My Water Data Means


Water data isn't always easy to interpret, but by following the links on this page you should be able to have most of your questions answered. By clicking the name of a water contaminant or secondary substance you can learn about that specific substance. Ultimately this page should give you some insight towards learning if your water is safe, what water filter you should buy (if any), and how well your local water compares against other sources.

Sources


The origin of MyTapWater.org's water data is explained on our Data Sources page.

Why Is My Water Data Not More Recent?


The recency of the data for your ZIP code depends on the last your water source was tested, by a federal, state, or local agency. More information about the timing can be determined by learning about the dataset in question and seeing how often the EPA (other another governing body) mandated testing.