Grand Prairie Regional Water Water System

MyTapWater.org's tap water quality report is the compilation of data collected from federal, state, and local government agencies, most prominently the EPA. We strive to populate the report with the latest data concerning water contaminants, lead and copper levels, and water quality violations. We only collect drinking water data from public water systems.

PWS Service Information
PWS ID: AR0000738
Type: Community water system
EPA Region: 06
Primary Service Area: Residential Area
Primary Source: Ground water
Population Served: 13,500
Contact Information
SMITH, BRYAN
SMITH, BRYAN
P O BOX 850
STUTTGART, AR 72160

This public water system services 1 municipality in 1 county.

Summary Results


A summary view of tests in which a water contaminant found to exceed the Maximum Contaminant Level (MCL) set by the EPA.

Maximum Contaminant Levels Exceeded (by year):

2013   (0) 2014   (1) 2015   (0) 2016   (0) 2017   (0) 2018   (5)
chlorate HAA5
HAA6Br
HAA9
germanium
manganese

Contaminant Detailed Results


This a view of violations of maximum contaminant levels. Use the expanded view see result data for a drinking water contaminant, the minimum level that can be recognized in a test (MRL), and upper limit that is considered healthy (HRL).

HAA5

Year Test Date MRLMinimum Reporting Level HRLHealth Risk Limit Test Result
2018 2018-03-07 0 0.00 2.149

HAA6Br

Year Test Date MRLMinimum Reporting Level HRLHealth Risk Limit Test Result
2018 2018-03-07 0 0.00 3.009

HAA9

Year Test Date MRLMinimum Reporting Level HRLHealth Risk Limit Test Result
2018 2018-03-07 0 0.00 3.945

chlorate

Year Test Date MRLMinimum Reporting Level HRLHealth Risk Limit Test Result
2015 2015-04-15 20 210 143
2015 2015-04-15 20 210 207
2015 2015-04-15 20 210 171
2014 2014-10-15 20 210 430
2014 2014-10-15 20 210 842
2014 2014-10-15 20 210 460

germanium

Year Test Date MRLMinimum Reporting Level HRLHealth Risk Limit Test Result
2018 2018-02-14 0.3 0.00 < 0.3
2018 2018-02-14 0.3 0.00 < 0.3
2018 2018-02-14 0.3 0.00 < 0.3

manganese

Year Test Date MRLMinimum Reporting Level HRLHealth Risk Limit Test Result
2018 2018-02-14 0.4 0.00 66.4
2018 2018-02-14 0.4 0.00 2.2
2018 2018-02-14 0.4 0.00 0.8

Other Water Contaminants Tested


The following contaminants were tested and found to be within national EPA guidelines.

Contaminant MRLMinimum Reporting Level HRLHealth Risk Limit Avg Result
chromium 0.2 100 < 0.2 [+] Expand Test Data
Year Test Date MRL HRL Test Result
2015 2015-04-15 0.2 100 < 0.2
2015 2015-04-15 0.2 100 < 0.2
2015 2015-04-15 0.2 100 < 0.2
2014 2014-10-15 0.2 100 < 0.2
2014 2014-10-15 0.2 100 < 0.2
2014 2014-10-15 0.2 100 < 0.2
chromium-6 0.03 0 < 0.03 [+] Expand Test Data
Year Test Date MRL HRL Test Result
2015 2015-04-15 0.03 0 < 0.03
2015 2015-04-15 0.03 0 < 0.03
2015 2015-04-15 0.03 0 < 0.03
2014 2014-10-15 0.03 0 < 0.03
2014 2014-10-15 0.03 0 < 0.03
2014 2014-10-15 0.03 0 < 0.03
cobalt 1 70 < 1 [+] Expand Test Data
Year Test Date MRL HRL Test Result
2015 2015-04-15 1 70 < 1
2015 2015-04-15 1 70 < 1
2015 2015-04-15 1 70 < 1
2014 2014-10-15 1 70 < 1
2014 2014-10-15 1 70 < 1
2014 2014-10-15 1 70 < 1
molybdenum 1 40 < 1 [+] Expand Test Data
Year Test Date MRL HRL Test Result
2015 2015-04-15 1 40 < 1
2015 2015-04-15 1 40 < 1
2015 2015-04-15 1 40 < 1
2014 2014-10-15 1 40 < 1
2014 2014-10-15 1 40 < 1
2014 2014-10-15 1 40 < 1
strontium 0.3 1500 433.6667 [+] Expand Test Data
Year Test Date MRL HRL Test Result
2015 2015-04-15 0.3 1500 468
2015 2015-04-15 0.3 1500 100
2015 2015-04-15 0.3 1500 428
2014 2014-10-15 0.3 1500 734
2014 2014-10-15 0.3 1500 166
2014 2014-10-15 0.3 1500 706
vanadium 0.2 21 0.0383 [+] Expand Test Data
Year Test Date MRL HRL Test Result
2015 2015-04-15 0.2 21 < 0.2
2015 2015-04-15 0.2 21 < 0.2
2015 2015-04-15 0.2 21 0.23
2014 2014-10-15 0.2 21 < 0.2
2014 2014-10-15 0.2 21 < 0.2
2014 2014-10-15 0.2 21 < 0.2
1,1-dichloroethane 0.03 6.14 < 0.03 [+] Expand Test Data
Year Test Date MRL HRL Test Result
2015 2015-04-15 0.03 6.14 < 0.03
2015 2015-04-15 0.03 6.14 < 0.03
2014 2014-10-15 0.03 6.14 < 0.03
2014 2014-10-15 0.03 6.14 < 0.03
1,2,3-trichloropropane 0.03 0.0004 < 0.03 [+] Expand Test Data
Year Test Date MRL HRL Test Result
2015 2015-04-15 0.03 0.0004 < 0.03
2015 2015-04-15 0.03 0.0004 < 0.03
2014 2014-10-15 0.03 0.0004 < 0.03
2014 2014-10-15 0.03 0.0004 < 0.03
1,3-butadiene 0.1 0.0103 < 0.1 [+] Expand Test Data
Year Test Date MRL HRL Test Result
2015 2015-04-15 0.1 0.0103 < 0.1
2015 2015-04-15 0.1 0.0103 < 0.1
2014 2014-10-15 0.1 0.0103 < 0.1
2014 2014-10-15 0.1 0.0103 < 0.1
1,4-dioxane 0.07 0.35 < 0.07 [+] Expand Test Data
Year Test Date MRL HRL Test Result
2015 2015-04-15 0.07 0.35 < 0.07
2015 2015-04-15 0.07 0.35 < 0.07
2014 2014-10-15 0.07 0.35 < 0.07
2014 2014-10-15 0.07 0.35 < 0.07
bromomethane 0.2 140 < 0.2 [+] Expand Test Data
Year Test Date MRL HRL Test Result
2015 2015-04-15 0.2 140 < 0.2
2015 2015-04-15 0.2 140 < 0.2
2014 2014-10-15 0.2 140 < 0.2
2014 2014-10-15 0.2 140 < 0.2
chloromethane 0.2 2.69 < 0.2 [+] Expand Test Data
Year Test Date MRL HRL Test Result
2015 2015-04-15 0.2 2.69 < 0.2
2015 2015-04-15 0.2 2.69 < 0.2
2014 2014-10-15 0.2 2.69 < 0.2
2014 2014-10-15 0.2 2.69 < 0.2
Halon 1011 0.06 90 < 0.06 [+] Expand Test Data
Year Test Date MRL HRL Test Result
2015 2015-04-15 0.06 90 < 0.06
2015 2015-04-15 0.06 90 < 0.06
2014 2014-10-15 0.06 90 < 0.06
2014 2014-10-15 0.06 90 < 0.06
HCFC-22 0.08 0 < 0.08 [+] Expand Test Data
Year Test Date MRL HRL Test Result
2015 2015-04-15 0.08 0 < 0.08
2015 2015-04-15 0.08 0 < 0.08
2014 2014-10-15 0.08 0 < 0.08
2014 2014-10-15 0.08 0 < 0.08
PFBS 0.09 0 < 0.09 [+] Expand Test Data
Year Test Date MRL HRL Test Result
2015 2015-04-15 0.09 0 < 0.09
2015 2015-04-15 0.09 0 < 0.09
2014 2014-10-15 0.09 0 < 0.09
2014 2014-10-15 0.09 0 < 0.09
PFHpA 0.01 0 < 0.01 [+] Expand Test Data
Year Test Date MRL HRL Test Result
2015 2015-04-15 0.01 0 < 0.01
2015 2015-04-15 0.01 0 < 0.01
2014 2014-10-15 0.01 0 < 0.01
2014 2014-10-15 0.01 0 < 0.01
PFHxS 0.03 0 < 0.03 [+] Expand Test Data
Year Test Date MRL HRL Test Result
2015 2015-04-15 0.03 0 < 0.03
2015 2015-04-15 0.03 0 < 0.03
2014 2014-10-15 0.03 0 < 0.03
2014 2014-10-15 0.03 0 < 0.03
PFNA 0.02 0 < 0.02 [+] Expand Test Data
Year Test Date MRL HRL Test Result
2015 2015-04-15 0.02 0 < 0.02
2015 2015-04-15 0.02 0 < 0.02
2014 2014-10-15 0.02 0 < 0.02
2014 2014-10-15 0.02 0 < 0.02
PFOA 0.02 0.07 < 0.02 [+] Expand Test Data
Year Test Date MRL HRL Test Result
2015 2015-04-15 0.02 0.07 < 0.02
2015 2015-04-15 0.02 0.07 < 0.02
2014 2014-10-15 0.02 0.07 < 0.02
2014 2014-10-15 0.02 0.07 < 0.02
PFOS 0.04 0.07 < 0.04 [+] Expand Test Data
Year Test Date MRL HRL Test Result
2015 2015-04-15 0.04 0.07 < 0.04
2015 2015-04-15 0.04 0.07 < 0.04
2014 2014-10-15 0.04 0.07 < 0.04
2014 2014-10-15 0.04 0.07 < 0.04

Lead and Copper Data


Lead and copper are recorded separately from other contaminants because of the Lead and Copper Rule. As with all other results, these are the findings at the water supply level. Lead and copper can be — and often are — deposited in drinking water in between the water facility and your tap.

Sample ID Contaminant Sampling Start Date Sampling End Date Result
AR1574 lead 2014-01-01 2016-12-31 0.002mg/L
AR1236 lead 2011-01-01 2013-12-31 0.003mg/L
AR840 lead 2008-01-01 2010-12-31 0.004mg/L

Violations


Known violations of the Safe Drinking Water Act as recorded by the EPA.

Compliance Dates Rule Violation Type Contaminant Name Status
2015-02-01 - 2015-02-28 Total Coliform Rule Maximum Contaminant Level Violation, Monthly (TCR) Coliform (TCR) Returned to Compliance
2014-09-01 - 2014-09-30 Total Coliform Rule Maximum Contaminant Level Violation, Monthly (TCR) Coliform (TCR) Returned to Compliance
2014-07-01 - 2014-07-31 Total Coliform Rule Maximum Contaminant Level Violation, Monthly (TCR) Coliform (TCR) Returned to Compliance
2011-10-01 - 2011-10-31 Ground Water Rule Monitoring of Treatment (SWTR-Unfilt/GWR) Groundwater Rule Returned to Compliance
2008-10-01 - 2008-10-31 Total Coliform Rule Maximum Contaminant Level Violation, Monthly (TCR) Coliform (TCR) Returned to Compliance
2007-01-01 - 2007-01-31 Total Coliform Rule Maximum Contaminant Level Violation, Monthly (TCR) Coliform (TCR) Returned to Compliance
2004-07-01 - 2004-07-31 Total Coliform Rule Maximum Contaminant Level Violation, Monthly (TCR) Coliform (TCR) Returned to Compliance
2004-05-01 - 2004-05-31 Total Coliform Rule Maximum Contaminant Level Violation, Monthly (TCR) Coliform (TCR) Returned to Compliance
2003-12-01 - 2003-12-31 Total Coliform Rule Monitoring, Routine Minor (TCR) Coliform (TCR) Returned to Compliance
2003-11-01 - 2003-11-30 Total Coliform Rule Monitoring, Routine Minor (TCR) Coliform (TCR) Returned to Compliance
- N/A Total Coliform Rule Notification, Public Coliform (TCR) Known
- N/A Total Coliform Rule Monitoring, Routine Major (TCR) Coliform (TCR) Known

Local Water Testing


Find a lab in your area so you can get your tap or well water tested. This list contains both governmental and private labs, all of which are EPA-certified for drinking water testing.

Lab Location Zip Code
McClelland Consulting Engineer Little Rock, AR 72204
Central Arkansas Water LITTLE ROCK, AR 72212
Environmental Services Company Little Rock, AR 72215

Water Bill Information


Convenient information about your water service.

Unable to identify any billing information about Grand Prairie Regional Water (AR0000738).

What My Water Data Means


Water data isn't always easy to interpret, but by following the links on this page you should be able to have most of your questions answered. By clicking the name of a water contaminant or secondary substance you can learn about that specific substance. Ultimately this page should give you some insight towards learning if your water is safe, what water filter you should buy (if any), and how well your local water compares against other sources.

Sources


The origin of MyTapWater.org's water data is explained on our Data Sources page.

Why Is My Water Data Not More Recent?


The recency of the data for your ZIP code depends on the last your water source was tested, by a federal, state, or local agency. More information about the timing can be determined by learning about the dataset in question and seeing how often the EPA (other another governing body) mandated testing.